2,510 research outputs found
Corrector theory for MsFEM and HMM in random media
We analyze the random fluctuations of several multi-scale algorithms such as
the multi-scale finite element method (MsFEM) and the finite element
heterogeneous multiscale method (HMM), that have been developed to solve
partial differential equations with highly heterogeneous coefficients. Such
multi-scale algorithms are often shown to correctly capture the homogenization
limit when the highly oscillatory random medium is stationary and ergodic. This
paper is concerned with the random fluctuations of the solution about the
deterministic homogenization limit. We consider the simplified setting of the
one dimensional elliptic equation, where the theory of random fluctuations is
well understood. We develop a fluctuation theory for the multi-scale algorithms
in the presence of random environments with short-range and long-range
correlations. What we find is that the computationally more expensive method
MsFEM captures the random fluctuations both for short-range and long-range
oscillations in the medium. The less expensive method HMM correctly captures
the fluctuations for long-range oscillations and strongly amplifies their size
in media with short-range oscillations. We present a modified scheme with an
intermediate computational cost that captures the random fluctuations in all
cases.Comment: 41 page
Inverse Scattering and Acousto-Optic Imaging
We propose a tomographic method to reconstruct the optical properties of a
highly-scattering medium from incoherent acousto-optic measurements. The method
is based on the solution to an inverse problem for the diffusion equation and
makes use of the principle of interior control of boundary measurements by an
external wave field.Comment: 10 page
Measurement of Magnetization Dynamics in Single-Molecule Magnets Induced by Pulsed Millimeter-Wave Radiation
We describe an experiment aimed at measuring the spin dynamics of the Fe8
single-molecule magnet in the presence of pulsed microwave radiation. In
earlier work, heating was observed after a 0.2-ms pulse of intense radiation,
indicating that the spin system and the lattice were out of thermal equilibrium
at millisecond time scale [Bal et al., Europhys. Lett. 71, 110 (2005)]. In the
current work, an inductive pick-up loop is used to probe the photon-induced
magnetization dynamics between only two levels of the spin system at much
shorter time scales (from ns to us). The relaxation time for the magnetization,
induced by a pulse of radiation, is found to be on the order of 10 us.Comment: 3 RevTeX pages, including 3 eps figures. The paper will appear in the
Journal of Applied Physics as MMM'05 conference proceeding
Radiation- and Phonon-Bottleneck-Induced Tunneling in the Fe8 Single-Molecule Magnet
We measure magnetization changes in a single crystal of the single-molecule
magnet Fe8 when exposed to intense, short (<20 s) pulses of microwave
radiation resonant with the m = 10 to 9 transition. We find that radiation
induces a phonon bottleneck in the system with a time scale of ~5 s. The
phonon bottleneck, in turn, drives the spin dynamics, allowing observation of
thermally assisted resonant tunneling between spin states at the 100-ns time
scale. Detailed numerical simulations quantitatively reproduce the data and
yield a spin-phonon relaxation time of T1 ~ 40 ns.Comment: 6 RevTeX pages, including 4 EPS figures, version accepted for
publicatio
Inverse Diffusion Theory of Photoacoustics
This paper analyzes the reconstruction of diffusion and absorption parameters
in an elliptic equation from knowledge of internal data. In the application of
photo-acoustics, the internal data are the amount of thermal energy deposited
by high frequency radiation propagating inside a domain of interest. These data
are obtained by solving an inverse wave equation, which is well-studied in the
literature. We show that knowledge of two internal data based on well-chosen
boundary conditions uniquely determines two constitutive parameters in
diffusion and Schroedinger equations. Stability of the reconstruction is
guaranteed under additional geometric constraints of strict convexity. No
geometric constraints are necessary when internal data for well-chosen
boundary conditions are available, where is spatial dimension. The set of
well-chosen boundary conditions is characterized in terms of appropriate
complex geometrical optics (CGO) solutions.Comment: 24 page
Low temperature microwave emission from molecular clusters
We investigate the experimental detection of the electromagnetic radiation
generated in the fast magnetization reversal in Mn12-acetate at low
temperatures. In our experiments we used large single crystals and assemblies
of several small single crystals of Mn12-acetate placed inside a cylindrical
stainless steel waveguide in which an InSb hot electron device was also placed
to detect the radiation. All this was set inside a SQUID magnetometer that
allowed to change the magnetic field and measure the magnetic moment and the
temperature of the sample as the InSb detected simultaneously the radiation
emitted from the molecular magnets. Our data show a sequential process in which
the fast inversion of the magnetic moment first occurs, then the radiation is
detected by the InSb device, and finally the temperature of the sample
increases during 15 ms to subsequently recover its original value in several
hundreds of milliseconds.Comment: changed conten
Non-equilibrium Magnetization Dynamics in the Fe_8 Single-Molecule Magnet Induced by High-Intensity Microwave Radiation
Resonant microwave radiation applied to a single crystal of the molecular
magnet Fe_8 induces dramatic changes in the sample's magnetization. Transitions
between excited states are found even though at the nominal system temperature
these levels have negligible population. We find evidence that the sample heats
significantly when the resonance condition is met. In addition, heating is
observed after a short pulse of intense radiation has been turned off,
indicating that the spin system is out of equilibrium with the lattice.Comment: Version to appear in Europhysics Letters. Minor changes and updated
reference
Experimental Upper Bound on Superradiance Emission from Mn12 Acetate
We used a Josephson junction as a radiation detector to look for evidence of
the emission of electromagnetic radiation during magnetization avalanches in a
crystal assembly of Mn_12-Acetate. The crystal assembly exhibits avalanches at
several magnetic fields in the temperature range from 1.8 to 2.6 K with
durations of the order of 1 ms. Although a recent study shows evidence of
electromagnetic radiation bursts during these avalanches [J. Tejada, et al.,
Appl. Phys. Lett. {\bf 84}, 2373 (2004)], we were unable to detect any
significant radiation at well-defined frequencies. A control experiment with
external radiation pulses allows us to determine that the energy released as
radiation during an avalanche is less than 1 part in 10^4 of the total energy
released. In addition, our avalanche data indicates that the magnetization
reversal process does not occur uniformly throughout the sample.Comment: 4 RevTeX pages, 3 eps figure
- …