2 research outputs found

    Quantifying bacterial transfer from patients to staff during burns dressing and bed changes : implications for infection control

    Get PDF
    Routine nursing activities such as dressing/bed changes increase bacterial dispersal from burns patients, potentially contaminating healthcare workers (HCW) carrying out these tasks. HCW thus become vectors for transmission of nosocomial infection between patients. The suspected relationship between %total body surface area (%TBSA) of burn and levels of bacterial release has never been fully established. Bacterial contamination of HCW was assessed by contact plate samples (n = 20) from initially sterile gowns worn by the HCW during burns patient dressing/bed changes. Analysis of 24 gowns was undertaken and examined for relationships between %TBSA, time taken for activity, and contamination received by the HCW. Relationships between size of burn and levels of HCW contamination, and time taken for the dressing/bed change and levels of HCW contamination were best described by exponential models. Burn size correlated more strongly (R2 = 0.82, p < 0.001) than time taken (R2 = 0.52, p < 0.001), with levels of contamination received by the HCW. Contamination doubled with every 6–9% TBSA increase in burn size. Burn size was used to create a model to predict bacterial contamination received by a HCW carrying out bed/dressing changes. This may help with the creation of burn-specific guidelines on protective clothing worn by HCW caring for burns patients

    Clinical studies of the high-intensity narrow-spectrum light environmental decontamination system (HINS-light EDS), for continuous disinfection in the burn unit inpatient and outpatient settings

    Get PDF
    Infections are the leading cause of morbidity and mortality in burn patients and prevention of contamination from exogenous sources including the hospital environment is becoming increasingly emphasised. The High-Intensity Narrow-Spectrum light Environmental Decontamination System (HINS-light EDS) is bactericidal yet safe for humans, allowing continuous disinfection of the environment surrounding burn patients. Environmental samples were collected from inpatient isolation rooms and the outpatient clinic in the burn unit, and comparisons were then made between the bacterial contamination levels observed with and without use of the HINS-light EDS. Over 1000 samples were taken. Inpatient studies, with sampling carried out at 0800 h, demonstrated a significant reduction in the average number of bacterial colonies following HINS-light EDS use of between 27% and 75%, (p<0.05). There was more variation when samples were taken at times of increased activity in the room. Outpatient studies during clinics demonstrated a 61% efficacy in the reduction of bacterial contamination on surfaces throughout the room during the course of a clinic (p=0.02). The results demonstrate that use of the HINS-light EDS allows efficacious bacterial reductions over and above that achieved by standard cleaning and infection control measures in both inpatient and outpatient settings in the burn unit
    corecore