18 research outputs found

    Separation and Determination of Fatty Acids from Lipid Fractions by High-Performance Liquid Chromatography: Cholesterol Esters of Umbilical Cord Arteries

    Get PDF
    Preeclampsia is accompanied by an extensive remodeling of the extracellular matrix of umbilical cord. It is associated with an increase in collagen content in the umbilical cord artery. Furthermore, preeclampsia distinctly reduces proteolytic and gelatinolytic activity, especially after activation with various agents

    Ciecze elektroreologiczne zawierające polielektrolity

    No full text
    Electrorheological (ER) fluids belong to the broadly studied class of so called "intelligent materials" whose properties are sensitive to external stimuli. The ER fluids increase their viscosity upon application of an electric field. This paper reports the results of electrorheological experiments and describes a synthetic procedure leading to an ER suspension exhibiting predetermined characteristics. The fluid was designed for application in a prototype ER clutch.Ciecze elektroreologiczne (ER) należą do intensywnie badanej grupy tak zwanych inteligentnych materiałów, których właściwości można modyfikować za pomocą czynników zewnętrznych. Cechą charakterystyczną cieczy ER jest gwałtowny i odwracalny wzrost lepkości pod wpływem przyłożonego pola elektrycznego. Niniejsza praca zawiera wyniki eksperymentów elektroreologicznych i opis syntezy prowadzącej do otrzymania zawiesiny elektroreologicznej spełniającej określone parametry użytkowe. Ciecz została sporządzona w celu zastosowania w prototypowym sprzęgle elektroreologicznym

    CFD Modelling of Fire Ventilation in Road Tunnels

    No full text
    Cel: Celem pracy było wykonanie symulacji numerycznej rozwoju pożaru w tunelu drogowym za pomocą programu Fire Dynamics Simulator. Na tej podstawie została dokonana analiza wpływu mocy źródła pożaru na efektywność działania systemu wentylacji pożarowej. W pierwszej części artykułu przedstawiono zagadnienia związane z rozwojem pożaru. Skupiono się na aspektach teoretycznych parametrów, takich jak: rozchodzenie się dymu, rozwój pożaru, widzialność, szybkość wydzielania ciepła oraz temperatura maksymalna. Systemy wentylacji pożarowej, które są stosowane w tunelach drogowych zostały przedstawione na schematach, a także omówione zostały zasady ich działania. Kolejną część artykułu poświęcono przedstawieniu podstaw teoretycznych programu Fire Dynamics Simulator. Ostatnia część pracy zawiera opis przeprowadzonych badań oraz analizę i porównanie wyników. W części badawczej wykonano symulacje czterech scenariuszy, w zależności od mocy pożaru. Zebrane dane zostały poddane analizie. Sprawdzono, jak zachowuje się pożar w przestrzeni zamkniętej w zależności od mocy jego źródła. Dodatkowo przetestowano efektywność działania zastosowanego systemu wentylacji. Łącznie wykonano symulacje numeryczne z mocami pożaru: 202 MW, 157 MW, 119 MW oraz 67 MW. Metodologia: Artykuł został opracowany na podstawie przeglądu literatury i dostępnych w niej wyników prac naukowych dotyczących dynamiki zjawiska pożaru w tunelach drogowych, jak również badań numerycznych CFD w programie Fire Dynamics Simulator. Wnioski: Na podstawie wykonanych badań numerycznych przybliżono zjawiska, jakie zachodzą w trakcie pożaru w tunelu drogowym. Otrzymane dane można analizować i interpretować, wyciągając przy tym wnioski, które mogą zwiększyć bezpieczeństwo w tunelach. Jednym z najważniejszych aspektów, który ma bezpośredni wpływ na bezpieczeństwo ludzi podczas pożaru jest dobór odpowiedniego systemu wentylacji. Na rynku istnieje wiele rozwiązań systemowych, posiadających zarówno wady, jak i zalety. W badanych przypadkach wykorzystano wentylację wzdłużną wraz z dwoma wentylatorami wywiewnymi. Wentylacja wzdłużna wytwarzała przepływ powietrza o prędkości 2 m/s w całym przekroju tunelu. Na podstawie otrzymanych wyników można stwierdzić, że przepływ powietrza o prędkości 2 m/s ogranicza rozprzestrzenianie się ciepła na wysokości 1,8 m od poziomu podłoża tunelu, niezależnie od mocy pożarów przyjętych w badaniach. Najwcześniej temperatura zaczęła wzrastać dla pożaru o mocy 119 MW, a najpóźniej dla pożaru o mocy 67 MW. W dalszych częściach tunelu temperatura zmieniała się w wąskim zakresie i nie przekroczyła 22 ̊C. Temperatura nad źródłem dochodziła do wartości 700 ̊C, natomiast za centrum pożaru maksymalna temperatura wynosiła około 1200 ̊C.Aim: The purpose of this work was to perform numerical simulation of fire development in a road tunnel using the Fire Dynamics Simulator (FDS) programme. On this basis, an analysis of the impact of the fire source's power on the effectiveness of the fire ventilation system was performed. The first stage of the work presents issues related to fire development. The focus was on presenting the theoretical part of the parameters, such as smoke propagation, fire development, visibility, heat release rate and maximum temperature. The next stage of the article focuses on presenting the theoretical foundations about the Fire Dynamics Simulator program. The last stage of the work contains a description of the conducted research, as well as the analysis and comparison of results. In the research part, simulations of 4 scenarios were carried out, depending on the fire power. The collected data was analysed and conclusions were drawn. It was checked how a fire in a confined space behaves depending on the power of the source. In addition, the effectiveness of the ventilation system used was tested. Introduction: Numerical simulations are used to improve fire safety in road tunnels. Numerical calculations allow to assess the suitability of the fire protection systems used. One such programme is the Fire Dynamics Simulator, which was discussed at work. In addition, theoretical issues related to fire development were presented. Issues such as maximum temperature, visibility, the process of smoke propagation and the power of fire were raised. Fire ventilation systems that are used in road tunnels are presented in the diagrams, along with the principles of their operation discussed. In total, numerical simulations with fire performance were performed: 202 MW, 157 MW, 119 MW and 67 MW.Methodology: The article was compiled on the basis of the review of literature available in the publications of the results of scientific works on the dynamics of the fire phenomenon in road tunnels, as well as numerical CFD studies in the Fire Dynamics Simulator program. Conclusions: Based on the numerical tests carried out, the phenomena that occur during a fire in a road tunnel are approximated. The data received can be analysed and interpreted, and conclusions can be drawn to increase safety in tunnels. One of the most important aspects that has a direct impact on the safety of people during a fire is the selection of an appropriate ventilation system. There are many system solutions on the market that have both pros and cons. In the cases studied, longitudinal ventilation was used along with two exhaust fans. Longitudinal ventilation generated airflow at the velocity of 2 m / s in the entire tunnel cross-section. Based on the obtained results, it can be concluded that the airflow rate of 2 m / s limits the spread of heat at a height of 1.8 m from the ground level of the tunnel, regardless of the power of fires adopted in the tests. The earliest temperature increase occurred for a 119 MW fire, and at the latest for a fire of 67 MW. In the further parts of the tunnel, the temperature changed in a narrow range and did not exceed 22 ̊C. The temperature over the source reached 700 ̊C, while the centre of the fire reached the maximum temperature of 1200 ̊C

    Law's Iconoclasts

    No full text

    Method of modification of asphalt mix by rubber with "tecRoad" additive

    No full text
    W artykule przedstawiono innowacyjny materiał i prostą technologię stosowania gumy ze zużytych opon samochodowych w nawierzchniach asfaltowych z zastosowaniem nowego produktu - granulatu gumowo-asfaltowego "tecRoad". Dotychczas stosowane skuteczne technologie modyfikacji asfaltu gumą metodą na mokro wymagają specjalnych, kosztownych instalacji. Mieszanki z granulatem asfaltowym wykazały dobrą odporność na deformacje w wysokiej temperaturze, dobrą odporność na pękanie w niskiej temperaturze oraz na działanie wody.The paper presents innovative material and simply technology for application of crumb rubber from tyres in asphalt pavement with use of new product - rubber-bitumen granulate "tecRoad". Effective technology of wed method applied up-to-now requires specific and expensive installations. Mixes with asphalt granulate showed good resistance to deformation at high temperature, good resistance to cracking at low temperature, and to water as well

    Laboratory evaluation of polymer modified bitumen with crumb rubber for use in high modulus asphalt concrete. Part 1, Binder testing

    No full text
    Wykorzystanie materiałów z recyklingu opon samochodowych w nawierzchni drogowych jest przedmiotem badań naukowych od wielu lat. W rafinerii LOTOS Asfalt opracowano nowy typ polimeroasfaltu z dodatkiem granulatu gumowego. Niniejsza publikacja przedstawia wyniki prac badawczych prowadzonych w IBDiM. Celem było przeprowadzenie ocenę laboratoryjnej lepiszcza 25/55-60 CR i oceny możliwości jego zastosowania do betonu asfaltowego o wysokim module (ACWMS). Artykuł podzielony na dwie części przedstawiona ocenę laboratoryjną przydatności asfaltu 25/55-60 CR do zastosowania w betonie asfaltowym o wysokim module sztywności ACWMS. W części I przedstawiono badania lepiszczy, podczas gdy druga część dotyczy mieszanek ACWMS.The use of materials from recycled car tires in road pavements has been a subject of interest for scientific research for many years. A new type of polymer modified binder with crumb rubber was developed by the refinery of LOTOS Asphalt. This publication presents the results of research work carried out in IBDiM (Road and Bridge Research Institute). The aim was to perform laboratory evaluation of a binder 25/55-60 CR and assess the possibility of its application for high modulus asphalt concrete (ACWMS). Paper divided in two parts presents laboratory evaluation on usability of PMB modified with crumb rubber in high modulus asphalt concrete. Part I focuses on binder tests is devoted to binder tests, while the second part deals with bituminous mix

    Evaluation of asphalt pavement resistance for deformations on the base of proposed binder functional parameter. Part 1, Binder tests

    No full text
    Deformacje trwałe nawierzchni występujące w podwyższonej temperaturze prowadzą do powstawania kolein. Autorzy zaproponowali własne kryterium odporności na trwałe deformacje - parametr deformacji zdefiniowany jako iloraz odkształceń w powtarzalnym pełzaniu i długotrwałej relaksacji. Analiza odporności na trwałe deformacje mieszanki asfaltowej wykazała poprawność zaproponowanego parametru.Permanent deformations of asphalt pavement in slight temperature lead to ratting. The authors proposed their own criterion of resistance for permanent deformations - deformation parameter defined as a ratio of deformations in repeated creep and long term relaxation. Analysis of resistance for permanent deformations of asphalt mix indicated correctness of proposed parameter

    Evaluation of asphalt pavement resistance for deformations on the base of proposed binder functional parameter. Part 2, Asphalt mix

    No full text
    W części 1 autorzy zdefiniowali parametr funkcjonalny lepiszcza, jako iloraz odkształcenia w powtarzalnym pełzaniu i długotrwałej relaksacji. Obecnie wykonano badania koleinowania w małym i dużym aparacie w temperaturze 10°C i 30°C. Badania wykazały, że istnieje korelacja między tym parametrem a głębokością koleiny mieszanki mineralno-asfaltowej. Korelacja okazała się wyższa w temp. 10°C.In part 1, the authors proposed binder functional parameter, as a ratio of deformation in repeated creep and long term relaxation. Now, rutting tests have been made in small and large apparatus in temperature 10°C and 30°C. The tests showed correlation between this parameter rut depth. The correlation occurred higher in temperature 10°C
    corecore