    Effect of novel endoscope cleaning brush on duodenoscope contamination

    Get PDF
    Background and aims:Current duodenoscope reprocessing protocols are insufficient to prevent contamination and require adaptations to prevent endoscopy-associated infections (EAI). This study aimed to investigate the effect of a new endoscope cleaning brush on the contamination rate of ready-to-use duodenoscopes. Methods:This retrospective before-and-after intervention study collected duodenoscope surveillance culture results from March 2018 to June 2022. Contamination was defined as ≥1 colony-forming units of gastrointestinal or oral microorganisms (MGO). In December 2020, an endoscope cleaning brush with a sweeper design was introduced as the intervention in the manual cleaning of duodenoscopes. A logistic mixed effects model was used to study the effects of the intervention. Results:Data were collected from 176 culture sets before the new brush's introduction and 81 culture sets after. Pre-introduction, culture sets positive with MGO comprised 45.5% (95% CI: 38.3%-52.8%, 80/176), decreasing to 17.3% (95% CI: 10.6%-26.9%, 14/81) after implementing the new brush. Compared to the former brush, duodenoscopes cleaned with the new brush had lower odds of contamination with MGO (aOR=0.25, 95% CI: 0.11-0.58, p=0.001).Conclusions:Use of the new brush in manual cleaning reduced contamination with MGO and is expected to prevent EAIs. These findings should be confirmed in future prospective randomized studies.</p