29 research outputs found

    Relatively higher norms of blood flow velocity of major intracranial arteries in North-West Iran

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>Transcranial Doppler (TCD) is a noninvasive, less expensive and harmless hemodynamic study of main intracranial arteries. The aim of this study was to assess normal population values of cerebral blood flow velocity and its variation over age and gender in a given population.</p> <p>Findings</p> <p>Eighty healthy volunteers including 40 people with an age range of 25-40 years (group1) and 40 persons with an age range of 41-55 years (group2) were studied. In each group 20 males and 20 females were enrolled. Peak systolic, end diastolic and mean velocities of nine main intracranial arteries were determined using TCD. Mean age of the studied volunteers was 31.6 ± 4.50 years in group one and 47.2 ± 4.3 years in group two. Mean age among males was 40 years and among females it was 39. Mean blood flow velocity in middle, anterior and posterior cerebral arteries, vertebral and basilar arteries was 60 ± 8, 52 ± 9, 42 ± 6, 39 ± 8 and 48 ± 8 cm/sec respectively. Cerebral blood flow velocities among females were relatively higher than males. Cerebral blood flow velocity of left side was relatively higher than right side.</p> <p>Conclusion</p> <p>Compared to previous studies, cerebral blood flow velocity in this population was relatively higher.</p

    Reproducibility of Transcranial Doppler ultrasound in the middle cerebral artery

    Get PDF
    Abstract Background Transcranial Doppler ultrasound remains the only imaging modality that is capable of real-time measurements of blood flow velocity and microembolic signals in the cerebral circulation. We here assessed the repeatability and reproducibility of transcranial Doppler ultrasound in healthy volunteers and patients with symptomatic carotid artery stenosis. Methods Between March and August 2017, we recruited 20 healthy volunteers and 20 patients with symptomatic carotid artery stenosis. In a quiet temperature-controlled room, two 1-h transcranial Doppler measurements of blood flow velocities and microembolic signals were performed sequentially on the same day (within-day repeatability) and a third 7–14 days later (between-day reproducibility). Levels of agreement were assessed by interclass correlation co-efficient. Results In healthy volunteers (31±9 years, 11 male), within-day repeatability of Doppler measurements were 0.880 (95% CI 0.726–0.950) for peak velocity, 0.867 (95% CI 0.700–0.945) for mean velocity, and 0.887 (95% CI 0.741–0.953) for end-diastolic velocity. Between-day reproducibility was similar but lower: 0.777 (95% CI 0.526–0.905), 0.795 (95% CI 0.558–0.913), and 0.674 (95% CI 0.349–0.856) respectively. In patients (72±11 years, 11 male), within-day repeatability of Doppler measurements were higher: 0.926 (95% CI 0.826–0.970) for peak velocity, 0.922 (95% CI 0.817–0.968) for mean velocity, and 0.868 (95% CI 0.701–0.945) for end-diastolic velocity. Similarly, between-day reproducibility revealed lower values: 0.800 (95% CI 0.567–0.915), 0.786 (95% CI 0.542–0.909), and 0.778 (95% CI 0.527–0.905) respectively. In both cohorts, the intra-observer Bland Altman analysis demonstrated acceptable mean measurement differences and limits of agreement between series of middle cerebral artery velocity measurements with very few outliers. In patients, the carotid stenoses were 30–40% (n = 9), 40–50% (n = 6), 50–70% (n = 3) and > 70% (n = 2). No spontaneous embolisation was detected in either of the groups. Conclusions Transcranial Doppler generates reproducible data regarding the middle cerebral artery velocities. However, larger studies are needed to validate its clinical applicability. Trial registration ClinicalTrial.gov (ID NCT 03050567), retrospectively registered on 15/05/2017

    Transcranial Doppler Examination Techniques

    No full text
    corecore