89 research outputs found

    Sequence Expression of Supernumerary B Chromosomes: Function or Fluff?

    Get PDF
    B chromosomes are enigmatic heritable elements found in the genomes of numerous plant and animal species. Contrary to their broad distribution, most B chromosomes are non-essential. For this reason, they are regarded as genome parasites. In order to be stably transmitted through generations, many B chromosomes exhibit the ability to "drive", i.e., they transmit themselves at super-Mendelian frequencies to progeny through directed interactions with the cell division apparatus. To date, very little is understood mechanistically about how B chromosomes drive, although a likely scenario is that expression of B chromosome sequences plays a role. Here, we highlight a handful of previously identified B chromosome sequences, many of which are repetitive and non-coding in nature, that have been shown to be expressed at the transcriptional level. We speculate on how each type of expressed sequence could participate in B chromosome drive based on known functions of RNA in general chromatin- and chromosome-related processes. We also raise some challenges to functionally testing these possible roles, a goal that will be required to more fully understand whether and how B chromosomes interact with components of the cell for drive and transmission

    Presentation and Treatment Outcomes of Liberian Children Age 5 Years and Under Diagnosed With Severe Malaria

    Get PDF
    Malaria is endemic in Liberia with a prevalence rate of up to 60% in some regions, and it has been a major cause of death in children under 5 years of age. Prior to the recent Ebola epidemic, we undertook a prospective, hospital-based pilot study at the National Referral Hospital in Monrovia, to characterize the presentation, accuracy of diagnosis, and treatment outcomes of children presenting for treatment of malaria. From June 2013 to May 2014, we recruited children 5 years and under who presented to the JFK Medical Center with suspected malaria. We collected both clinical and laboratory data on admission and on discharge. We enrolled 477 patients with an average age of 1.6 years. Demographic factors associated with testing negative for malaria included regular bed net use and prior treatment for malaria. The most common presenting symptoms of severe malaria in this population were headache and seizures. Of 246 patients admitted and treated for severe malaria, 33% tested negative by rapid diagnostic test and blood smear for malaria. The case fatality rate was higher for the patients who tested negative for malaria (4.9%) versus those who tested positive (0.6%). Three children who tested negative for malaria showed evidence of undiagnosed Salmonella typhi infection. These results suggest that malaria may be overdiagnosed and that the diagnoses of other infectious diseases, which present in a similar fashion, may be neglected. These findings underscore the need to develop rapid diagnostic tests to screen for alternative causes of febrile illness

    Intercalibration of the barrel electromagnetic calorimeter of the CMS experiment at start-up

    Get PDF
    Calibration of the relative response of the individual channels of the barrel electromagnetic calorimeter of the CMS detector was accomplished, before installation, with cosmic ray muons and test beams. One fourth of the calorimeter was exposed to a beam of high energy electrons and the relative calibration of the channels, the intercalibration, was found to be reproducible to a precision of about 0.3%. Additionally, data were collected with cosmic rays for the entire ECAL barrel during the commissioning phase. By comparing the intercalibration constants obtained with the electron beam data with those from the cosmic ray data, it is demonstrated that the latter provide an intercalibration precision of 1.5% over most of the barrel ECAL. The best intercalibration precision is expected to come from the analysis of events collected in situ during the LHC operation. Using data collected with both electrons and pion beams, several aspects of the intercalibration procedures based on electrons or neutral pions were investigated

    Evaluation of Fermi Read-out of the ATLAS Tilecal Prototype

    Get PDF
    Prototypes of the \fermi{} system have been used to read out a prototype of the \atlas{} hadron calorimeter in a beam test at the CERN SPS. The \fermi{} read-out system, using a compressor and a 40 MHz sampling ADC, is compared to a standard charge integrating read-out by measuring the energy resolution of the calorimeter separately with the two systems on the same events. Signal processing techniques have been designed to optimize the treatment of \fermi{} data. The resulting energy resolution is better than the one obtained with the standard read-out

    The CMS High Level Trigger

    Full text link
    At the Large Hadron Collider at CERN the proton bunches cross at a rate of 40MHz. At the Compact Muon Solenoid experiment the original collision rate is reduced by a factor of O (1000) using a Level-1 hardware trigger. A subsequent factor of O(1000) data reduction is obtained by a software-implemented High Level Trigger (HLT) selection that is executed on a multi-processor farm. In this review we present in detail prototype CMS HLT physics selection algorithms, expected trigger rates and trigger performance in terms of both physics efficiency and timing.Comment: accepted by EPJ Nov 200

    CMS physics technical design report : Addendum on high density QCD with heavy ions

    Get PDF
    Peer reviewe

    Energy Resolution Performance of the CMS Electromagnetic Calorimeter

    Get PDF
    The energy resolution performance of the CMS lead tungstate crystal electromagnetic calorimeter is presented. Measurements were made with an electron beam using a fully equipped supermodule of the calorimeter barrel. Results are given both for electrons incident on the centre of crystals and for electrons distributed uniformly over the calorimeter surface. The electron energy is reconstructed in matrices of 3 times 3 or 5 times 5 crystals centred on the crystal containing the maximum energy. Corrections for variations in the shower containment are applied in the case of uniform incidence. The resolution measured is consistent with the design goals
    corecore