18 research outputs found

    Search for the Chiral Magnetic Effect in Au+Au collisions at sNN=27\sqrt{s_{_{\rm{NN}}}}=27 GeV with the STAR forward Event Plane Detectors

    Full text link
    A decisive experimental test of the Chiral Magnetic Effect (CME) is considered one of the major scientific goals at the Relativistic Heavy-Ion Collider (RHIC) towards understanding the nontrivial topological fluctuations of the Quantum Chromodynamics vacuum. In heavy-ion collisions, the CME is expected to result in a charge separation phenomenon across the reaction plane, whose strength could be strongly energy dependent. The previous CME searches have been focused on top RHIC energy collisions. In this Letter, we present a low energy search for the CME in Au+Au collisions at sNN=27\sqrt{s_{_{\rm{NN}}}}=27 GeV. We measure elliptic flow scaled charge-dependent correlators relative to the event planes that are defined at both mid-rapidity η<1.0|\eta|<1.0 and at forward rapidity 2.1<η<5.12.1 < |\eta|<5.1. We compare the results based on the directed flow plane (Ψ1\Psi_1) at forward rapidity and the elliptic flow plane (Ψ2\Psi_2) at both central and forward rapidity. The CME scenario is expected to result in a larger correlation relative to Ψ1\Psi_1 than to Ψ2\Psi_2, while a flow driven background scenario would lead to a consistent result for both event planes[1,2]. In 10-50\% centrality, results using three different event planes are found to be consistent within experimental uncertainties, suggesting a flow driven background scenario dominating the measurement. We obtain an upper limit on the deviation from a flow driven background scenario at the 95\% confidence level. This work opens up a possible road map towards future CME search with the high statistics data from the RHIC Beam Energy Scan Phase-II.Comment: main: 8 pages, 5 figures; supplementary material: 2 pages, 1 figur

    Age related changes in refractive index distribution and power of the human lens as measured by magnetic resonance-micro imaging in vitro

    Get PDF
    We report a new technique for non-invasively mapping the refractive index distribution through the eye lens using magnetic resonance micro-imaging. The technique is applied to map the refractive index distribution throughout the sagittal plane of 18 human eye lenses ranging in age from 14 to 82 years in vitro. The results are compared with standard models for the human eye lens. They confirm that the refractive index distribution, when plotted as a function of normalised lens radius, is a function of lens age and differs both between the equatorial and axial directions and between the anterior and posterior halves of the optical axis. The refractive index of the lens nucleus exhibits a significant reduction with age amounting to 3:4 0:6 104 years1. The contribution of the gradient index (GRIN) to the lens power decreases by 0:286 0:067 D/year, accounting almost entirely for the estimated overall change in lens power with age for these lenses, which were probably in their most accommodated state. The results provide experimental verification of hypothesised changes in the GRIN that have previously been invoked as contributing to presbyopia and support the hypothesis that changes in the GRIN are sufficient to offset effects of increasing curvature of human lenses with age in their unaccommodated state
    corecore