25 research outputs found

    Remote Laboratory for E-Learning of Systems on Chip and Their Applications to Nuclear and Scientific Instrumentation

    Get PDF
    Configuring and setting up a remote access laboratory for an advanced online school on fully programmable System-on-Chip (SoC) proved to be an outstanding challenge. The school, jointly organized by the International Centre for Theoretical Physics (ICTP) and the International Atomic Energy Agency (IAEA), focused on SoC and its applications to nuclear and scientific instrumentation and was mainly addressed to physicists, computer scientists and engineers from developing countries. The use of e-learning tools, which some of them adopted and others developed, allowed the school participants to directly access both integrated development environment software and programmable SoC platforms. This facilitated the follow-up of all proposed exercises and the final project. During the four weeks of the training activity, we faced and overcame different technology and communication challenges, whose solutions we describe in detail together with dedicated tools and design methodology. We finally present a summary of the gained experience and an assessment of the results we achieved, addressed to those who foresee to organize similar initiatives using e-learning for advanced training with remote access to SoC platforms

    A scalable High Voltage Power Supply System with system on chip control for Micro Pattern Gaseous Detectors

    Get PDF
    The requirements posed to high voltage power supply systems by the operation of Micro Pattern Gaseous Detectors are specific in terms of high resolution diagnostic features and intelligent dynamic voltage control. These requirements are needed both when technology development is performed and when extended detector systems are supplied and monitored. Systems satisfying all the needed features are not commercially available. A single channel high voltage system matching the Micro Pattern Gaseous Detector needs has been designed and realized, including its hardware and software components. The system employs a commercial DCDC converter and is coupled to a custom high resolution ammeter. Local intelligence, flexibility and high speed inter-connectivity are provided by a System on Chip Board and the use of a powerful FPGA. The single channel system has been developed, as critical milestone towards the realization of a multi-channel system. The design, implementation and performance of the system are reported in detail in this article, as well as the performance of the single channel power supply when connected to a Micro Pattern Gaseous Detector in realistic working condition during a test beam exercise

    Long term experience with perfluorobutane in COMPASS RICH

    Get PDF
    COMPASS RICH-1 has used high-purity perfluorobutane as radiator gas since 2001. The operation and control of the radiator gas has evolved over years with continuous improvements. We report on the experience gained in the 20 year-long operation of perfluorobutane as COMPASS RICH radiator. Very accurate values for the radiator gas refractive index are needed for high-performance particle identification. The procedure has evolved over years and the one presently in use, which provides refractive index estimate at the 1 ppm level, is discussed. Perfluorobutane procurement is becoming challenging, and the minimization of material waste is now a priority for the protection of the environment. Commercially available perfluorobutane needs dedicated filtering before usage and typical material losses in the filtering procedure were around 30%. Recent efforts allowed us to reduce them to about 5%. A potential alternative to fluorocarbon radiators in gaseous RICHes is also presented.Comment: 4 pages, 3 figures 2 table

    The high voltage system the novel MPGD-based photon detectors of COMPASS RICH-1 and its development towards a scalable HVPSS for MPGDs

    Get PDF
    The COMPASS RICH-1 detector underwent major upgrade in 2016 with the installation of fournovel MPGD-based photon detectors. They consist of large-size hybrid MPGDs with multi-layerarchitecture composed of two layers of Thick-GEMs and bulk resistive Micromegas. A dedicated highvoltage power supply system, realized with commercial devices, has been put in operation toprotect the detectors against errors by the operator, monitor and log voltages and currents at a 1 Hz rate, and automatically react to detector misbehavior; it includes also the HV compensation forthe detector gas pressure and temperature variations.The needs posed to the high voltagepower supply systems by the operation of Micro Pattern Gaseous Detectors pushed the development ofa novel single channel HV system able to overcome the performance of the commercial devices interms of high-resolution diagnostic features and intelligent dynamic voltage control. In this talkthe COMPASS HV system and its performance are illustrated, as well as the stability of the novelMPGD-based photon detectors during the physics data taking at COMPASS. The performance of thenovel single channel power supply system when connected to a single photon Micro Pattern GaseousDetector is presented in realistic working condition during a test beam with the preliminaryresults of multiple channels operation

    High-statistics measurement of Collins and Sivers asymmetries for transversely polarised deuterons

    Full text link
    New results are presented on a high-statistics measurement of Collins and Sivers asymmetries of charged hadrons produced in deep inelastic scattering of muons on a transversely polarised 6^6LiD target. The data were taken in 2022 with the COMPASS spectrometer using the 160 \gevv\ muon beam at CERN, balancing the existing data on transversely polarised proton targets. The first results from about two-thirds of the new data have total uncertainties smaller by up to a factor of three compared to the previous deuteron measurements. Using all the COMPASS proton and deuteron results, both the transversity and the Sivers distribution functions of the uu and dd quark, as well as the tensor charge in the measured xx-range are extracted. In particular, the accuracy of the dd quark results is significantly improved

    Spin Density Matrix Elements in Exclusive ρ0\rho ^0 Meson Muoproduction

    Full text link
    We report on a measurement of Spin Density Matrix Elements (SDMEs) in hard exclusive ρ0\rho ^0 meson muoproduction at COMPASS using 160~GeV/cc polarised μ+ \mu ^{+} and μ \mu ^{-} beams impinging on a liquid hydrogen target. The measurement covers the kinematic range 5.0~GeV/c2c^2 <W<< W < 17.0~GeV/c2c^2, 1.0 (GeV/cc)2^2 <Q2<< Q^2 < 10.0 (GeV/cc)2^2 and 0.01 (GeV/cc)2^2 <pT2<< p_{\rm{T}}^2 < 0.5 (GeV/cc)2^2. Here, WW denotes the mass of the final hadronic system, Q2Q^2 the virtuality of the exchanged photon, and pTp_{\rm{T}} the transverse momentum of the ρ0\rho ^0 meson with respect to the virtual-photon direction. The measured non-zero SDMEs for the transitions of transversely polarised virtual photons to longitudinally polarised vector mesons (γTVL\gamma^*_T \to V^{ }_L) indicate a violation of ss-channel helicity conservation. Additionally, we observe a dominant contribution of natural-parity-exchange transitions and a very small contribution of unnatural-parity-exchange transitions, which is compatible with zero within experimental uncertainties. The results provide important input for modelling Generalised Parton Distributions (GPDs). In particular, they may allow one to evaluate in a model-dependent way the role of parton helicity-flip GPDs in exclusive ρ0\rho ^0 production

    Collins and Sivers transverse-spin asymmetries in inclusive muoproduction of ρ0\rho^0 mesons

    Full text link
    The production of vector mesons in deep inelastic scattering is an interesting yet scarsely explored channel to study the transverse spin structure of the nucleon and the related phenomena. The COMPASS collaboration has performed the first measurement of the Collins and Sivers asymmetries for inclusively produced ρ0\rho^0 mesons. The analysis is based on the data set collected in deep inelastic scattering in 20102010 using a 160GeV/c160\,\,\rm{GeV}/c μ+\mu^+ beam impinging on a transversely polarized NH3\rm{NH}_3 target. The ρ0\rho^{0} mesons are selected from oppositely charged hadron pairs, and the asymmetries are extracted as a function of the Bjorken-xx variable, the transverse momentum of the pair and the fraction of the energy zz carried by the pair. Indications for positive Collins and Sivers asymmetries are observed

    Double J/ψJ/\psi production in pion-nucleon scattering at COMPASS

    Get PDF
    We present the study of the production of double J/ψJ/\psi mesons using COMPASS data collected with a 190 GeV/cc π\pi^- beam scattering off NH3_{3}, Al and W targets. Kinematic distributions of the collected double J/ψJ/\psi events are analysed, and the double J/ψJ/\psi production cross section is estimated for each of the COMPASS targets. The results are compared to predictions from single- and double-parton scattering models as well as the pion intrinsic charm and the tetraquark exotic resonance hypotheses. It is demonstrated that the single parton scattering production mechanism gives the dominant contribution that is sufficient to describe the data. An upper limit on the double intrinsic charm content of pion is evaluated. No significant signatures that could be associated with exotic tetraquarks are found in the double J/ψJ/\psi mass spectrum.Comment: 12 pages, 4 figure

    Global disparities in surgeons’ workloads, academic engagement and rest periods: the on-calL shIft fOr geNEral SurgeonS (LIONESS) study

    Get PDF
    : The workload of general surgeons is multifaceted, encompassing not only surgical procedures but also a myriad of other responsibilities. From April to May 2023, we conducted a CHERRIES-compliant internet-based survey analyzing clinical practice, academic engagement, and post-on-call rest. The questionnaire featured six sections with 35 questions. Statistical analysis used Chi-square tests, ANOVA, and logistic regression (SPSS® v. 28). The survey received a total of 1.046 responses (65.4%). Over 78.0% of responders came from Europe, 65.1% came from a general surgery unit; 92.8% of European and 87.5% of North American respondents were involved in research, compared to 71.7% in Africa. Europe led in publishing research studies (6.6 ± 8.6 yearly). Teaching involvement was high in North America (100%) and Africa (91.7%). Surgeons reported an average of 6.7 ± 4.9 on-call shifts per month, with European and North American surgeons experiencing 6.5 ± 4.9 and 7.8 ± 4.1 on-calls monthly, respectively. African surgeons had the highest on-call frequency (8.7 ± 6.1). Post-on-call, only 35.1% of respondents received a day off. Europeans were most likely (40%) to have a day off, while African surgeons were least likely (6.7%). On the adjusted multivariable analysis HDI (Human Development Index) (aOR 1.993) hospital capacity &gt; 400 beds (aOR 2.423), working in a specialty surgery unit (aOR 2.087), and making the on-call in-house (aOR 5.446), significantly predicted the likelihood of having a day off after an on-call shift. Our study revealed critical insights into the disparities in workload, access to research, and professional opportunities for surgeons across different continents, underscored by the HDI

    DAQ platform based on SoC-FPGA for high resolution time stamping in cosmic ray detection

    Get PDF
    Accurate timing in cosmic ray detection is critical for reconstruction of events from multiple scattered detectors. Since most of the detectors dedicated to study cosmic rays generate continuous analog signals, a precise timing depends on the sampling rate and the subsequent triggering system operating on the generated digital data stream. In this paper, a data acquisition platform based on a fully programmable System-On-Chip (SoC) and a high-speed analog to digital converter, able to manage 8-bit data resolution, 500MHz sampling rate and GPS connection for data synchronization is presented. The SoC is a ZYNQ 7000 device with a Field Programmable Gate Array (FPGA) and a dual core ARM processor embedded on a single chip. The system achieves 2 ns time resolution and is also able to increase data amplitude resolution through oversampling and can simultaneously generate a real time histogram of the incoming data. The platform has an embedded high voltage power supply control with temperature and pressure compensation for optimal and stable operation of different detectors. While the time critical activities are handled and carried out by the FPGA, software running on the dual core ARM processor with a real time operating system (FreeRTOS) provides Ethernet connection for remote control of the platform
    corecore