718 research outputs found

    Shape from Projections via Differentiable Forward Projector for Computed Tomography

    Full text link
    In computed tomography, the reconstruction is typically obtained on a voxel grid. In this work, however, we propose a mesh-based reconstruction method. For tomographic problems, 3D meshes have mostly been studied to simulate data acquisition, but not for reconstruction, for which a 3D mesh means the inverse process of estimating shapes from projections. In this paper, we propose a differentiable forward model for 3D meshes that bridge the gap between the forward model for 3D surfaces and optimization. We view the forward projection as a rendering process, and make it differentiable by extending recent work in differentiable rendering. We use the proposed forward model to reconstruct 3D shapes directly from projections. Experimental results for single-object problems show that the proposed method outperforms traditional voxel-based methods on noisy simulated data. We also apply the proposed method on electron tomography images of nanoparticles to demonstrate the applicability of the method on real data

    Geometric reconstruction methods for electron tomography

    Get PDF
    Electron tomography is becoming an increasingly important tool in materials science for studying the three-dimensional morphologies and chemical compositions of nanostructures. The image quality obtained by many current algorithms is seriously affected by the problems of missing wedge artefacts and nonlinear projection intensities due to diffraction effects. The former refers to the fact that data cannot be acquired over the full 180∘180^\circ tilt range; the latter implies that for some orientations, crystalline structures can show strong contrast changes. To overcome these problems we introduce and discuss several algorithms from the mathematical fields of geometric and discrete tomography. The algorithms incorporate geometric prior knowledge (mainly convexity and homogeneity), which also in principle considerably reduces the number of tilt angles required. Results are discussed for the reconstruction of an InAs nanowire

    Three dimensional mapping of Fe dopants in ceria nanocrystals using direct spectroscopic electron tomography

    Get PDF
    Electron tomography is a powerful technique for the 3D characterization of the morphology of nanostructures. Nevertheless, resolving the chemical composition of complex nanostructures in 3D remains challenging and the number of studies in which electron energy loss spectroscopy (EELS) is combined with tomography is limited. During the last decade, dedicated reconstruction algorithms have been developed for HAADF-STEM tomography using prior knowledge about the investigated sample. Here, we will use the prior knowledge that the experimental spectrum of each reconstructed voxel is a linear combination of a well-known set of references spectra in a so-called direct spectroscopic tomography technique. Based on a simulation experiment, it is shown that this technique provides superior results in comparison to conventional reconstruction methods for spectroscopic data, especially for spectrum images containing a relatively low signal to noise ratio. Next, this technique is used to investigate the spatial distribution of Fe dopants in Fe:Ceria nanoparticles in 3D. It is shown that the presence of the Fe2+ dopants is correlated with a reduction of the Ce atoms from Ce4+ towards Ce3+. In addition, it is demonstrated that most of the Fe dopants are located near the voids inside the nanoparticle

    Screening for left ventricular hypertrophy in patients with type 2 diabetes mellitus in the community

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>Left ventricular hypertrophy (LVH) is a strong predictor of cardiovascular disease and is common among patients with type 2 diabetes. However, no systematic screening for LVH is currently recommended for patients with type 2 diabetes. The purpose of this study was to determine whether NT-proBNP was superior to 12-lead electrocardiography (ECG) for detection of LVH in patients with type 2 diabetes.</p> <p>Methods</p> <p>Prospective cross-sectional study comparing diagnostic accuracy of ECG and NT-proBNP for the detection of LVH among patients with type 2 diabetes. Inclusion criteria included having been diagnosed for > 5 years and/or on treatment for type 2 diabetes; patients with Stage 3/4 chronic kidney disease and known cardiovascular disease were excluded. ECG LVH was defined as either the Sokolow-Lyon or Cornell voltage criteria. NT-proBNP level was measured using the Roche Diagnostics Elecsys assay. Left ventricular mass was assessed from echocardiography. Receiver operating characteristic curve analysis was carried out and area under the curve (AUC) was calculated.</p> <p>Results</p> <p>294 patients with type 2 diabetes were recruited, mean age 58 (SD 11) years, BP 134/81 ± 18/11 mmHg, HbA<sub>1c </sub>7.3 ± 1.5%. LVH was present in 164 patients (56%). In a logistic regression model age, gender, BMI and a history of hypertension were important determinants of LVH (p < 0.05). Only 5 patients with LVH were detected by either ECG voltage criteria. The AUC for NT-proBNP in detecting LVH was 0.68.</p> <p>Conclusions</p> <p>LVH was highly prevalent in asymptomatic patients with type 2 diabetes. ECG was an inadequate test to identify LVH and while NT-proBNP was superior to ECG it remained unsuitable for detecting LVH. Thus, there remains a need for a screening tool to detect LVH in primary care patients with type 2 diabetes to enhance risk stratification and management.</p

    Structure and vacancy distribution in copper telluride nanoparticles influence plasmonic activity in the near-infrared

    Get PDF
    Copper chalcogenides find applications in different domains including photonics, photothermal therapy and photovoltaics. CuTe nanocrystals have been proposed as an alternative to noble metal particles for plasmonics. Although it is known that deviations from stoichiometry are a prerequisite for plasmonic activity in the near-infrared, an accurate description of the material and its (optical) properties is hindered by an insufficient understanding of the atomic structure and the influence of defects, especially for materials in their nanocrystalline form. We demonstrate that the structure of Cu1.5±xTe nanocrystals can be determined using electron diffraction tomography. Real-space high-resolution electron tomography directly reveals the three-dimensional distribution of vacancies in the structure. Through first-principles density functional theory, we furthermore demonstrate that the influence of these vacancies on the optical properties of the nanocrystals is determined. Since our methodology is applicable to a variety of crystalline nanostructured materials, it is expected to provide unique insights concerning structure–property correlations

    High probability of comorbidities in bronchial asthma in Germany

    Get PDF
    Clinical experience has shown that allergic and non-allergic respiratory, metabolic, mental, and cardiovascular disorders sometimes coexist with bronchial asthma. However, no study has been carried out that calculates the chance of manifestation of these disorders with bronchial asthma in Saarland and Rhineland-Palatinate, Germany. Using ICD10 diagnoses from health care institutions, the present study systematically analyzed the co-prevalence and odds ratios of comorbidities in the asthma population in Germany. The odds ratios were adjusted for age and sex for all comorbidities for patients with asthma vs. without asthma. Bronchial asthma was strongly associated with allergic and with a lesser extent to non-allergic comorbidities: OR 7.02 (95% CI:6.83–7.22) for allergic rhinitis; OR 4.98 (95%CI:4.67–5.32) allergic conjunctivitis; OR 2.41 (95%CI:2.33–2.52) atopic dermatitis; OR 2.47 (95%CI:2.16–2.82) food allergy, and OR 1.69 (95%CI:1.61–1.78) drug allergy. Interestingly, increased ORs were found for respiratory diseases: 2.06 (95%CI:1.64–2.58) vocal dysfunction; 1.83 (95%CI:1.74–1.92) pneumonia; 1.78 (95%CI:1.73–1.84) sinusitis; 1.71 (95%CI:1.65–1.78) rhinopharyngitis; 2.55 (95%CI:2.03–3.19) obstructive sleep apnea; 1.42 (95%CI:1.25–1.61) pulmonary embolism, and 3.75 (95%CI:1.64–8.53) bronchopulmonary aspergillosis. Asthmatics also suffer from psychiatric, metabolic, cardiac or other comorbidities. Myocardial infarction (OR 0.86, 95%CI:0.79–0.94) did not coexist with asthma. Based on the calculated chances of manifestation for these comorbidities, especially allergic and respiratory, to a lesser extent also metabolic, cardiovascular, and mental disorders should be taken into consideration in the diagnostic and treatment strategy of bronchial asthma

    Epithelial antimicrobial peptides in host defense against infection

    Get PDF
    One component of host defense at mucosal surfaces seems to be epithelium-derived antimicrobial peptides. Antimicrobial peptides are classified on the basis of their structure and amino acid motifs. Peptides of the defensin, cathelicidin, and histatin classes are found in humans. In the airways, α-defensins and the cathelicidin LL-37/hCAP-18 originate from neutrophils. β-Defensins and LL-37/hCAP-18 are produced by the respiratory epithelium and the alveolar macrophage and secreted into the airway surface fluid. Beside their direct antimicrobial function, antimicrobial peptides have multiple roles as mediators of inflammation with effects on epithelial and inflammatory cells, influencing such diverse processes as proliferation, immune induction, wound healing, cytokine release, chemotaxis, protease-antiprotease balance, and redox homeostasis. Further, antimicrobial peptides qualify as prototypes of innovative drugs that might be used as antibiotics, anti-lipopolysaccharide drugs, or modifiers of inflammation

    Associations of oxygenated hemoglobin with disease burden and prognosis in stable COPD: Results from COSYCONET

    Get PDF
    We studied whether in patients with stable COPD blood gases (BG), especially oxygenated hemoglobin (OxyHem) as a novel biomarker confer information on disease burden and prognosis and how this adds to the information provided by the comorbidity pattern and systemic inflammation. Data from 2137 patients (GOLD grades 1-4) of the baseline dataset of the COSYCONET COPD cohort were used. The associations with dyspnea, exacerbation history, BODE-Index (cut-off 8000/mu L was 2.33 (95% CI: 1.60-3.39, p<0.0001). In stable COPD, the concentration of oxygenated hemoglobin provided additional information on disease state, especially mortality risk. OxyHem can be calculated from hemoglobin concentration and oxygen saturation without the need for the measurement of PaO2. It thus appears well suited for clinical use with minimal equipment, especially for GPs

    Associations of oxygenated hemoglobin with disease burden and prognosis in stable COPD : Results from COSYCONET

    Get PDF
    We studied whether in patients with stable COPD blood gases (BG), especially oxygenated hemoglobin (OxyHem) as a novel biomarker confer information on disease burden and prognosis and how this adds to the information provided by the comorbidity pattern and systemic inflammation. Data from 2137 patients (GOLD grades 1–4) of the baseline dataset of the COSYCONET COPD cohort were used. The associations with dyspnea, exacerbation history, BODE-Index (cut-off ≤2) and all-cause mortality over 3 years of follow-up were determined by logistic and Cox regression analyses, with sex, age, BMI and pack years as covariates. Predictive values were evaluated by ROC curves. Capillary blood gases included SaO2, PaO2, PaCO2, pH, BE and the concentration of OxyHem [haemoglobin (Hb) x fractional SaO2, g/dL] as a simple-to-measure correlate of oxygen content. Inflammatory markers were WBC, CRP, IL-6 and -8, TNF-alpha and fibrinogen, and comorbidities comprised a broad panel including cardiac and metabolic disorders. Among BG, OxyHem was associated with dyspnoea, exacerbation history, BODE-Index and mortality. Among inflammatory markers and comorbidities, only WBC and heart failure were consistently related to all outcomes. ROC analyses indicated that OxyHem provided information of a magnitude comparable to that of WBC, with optimal cut-off values of 12.5 g/dL and 8000/µL, respectively. Regarding mortality, OxyHem also carried independent, additional information, showing a hazard ratio of 2.77 (95% CI: 1.85–4.15, p  8000/µL was 2.33 (95% CI: 1.60–3.39, p < 0.0001). In stable COPD, the concentration of oxygenated hemoglobin provided additional information on disease state, especially mortality risk. OxyHem can be calculated from hemoglobin concentration and oxygen saturation without the need for the measurement of PaO2. It thus appears well suited for clinical use with minimal equipment, especially for GPs
    • …
    corecore