1,326 research outputs found

    Designing the future: strategy, design and the 4th Revolution: an introduction

    Get PDF
    This is an introduction to the special issue of California Management Review on Design Thinking (DT). This special issue joins the growing body of work exploring the idea of DT and whether DT makes a difference in terms enhancing or augmenting the impact of technology—and, as a result, innovation—in a positive way. We have chosen an interesting, relevant, and useful array of papers that provide different approaches, views, and interpretations of applied design thinking. These articles provide both management and scholarly readers with insights in how DT is used, as well as its impact and usefulness in a variety of contexts

    Monitoring Ion Channel Function In Real Time Through Quantum Decoherence

    Full text link
    In drug discovery research there is a clear and urgent need for non-invasive detection of cell membrane ion channel operation with wide-field capability. Existing techniques are generally invasive, require specialized nano structures, or are only applicable to certain ion channel species. We show that quantum nanotechnology has enormous potential to provide a novel solution to this problem. The nitrogen-vacancy (NV) centre in nano-diamond is currently of great interest as a novel single atom quantum probe for nanoscale processes. However, until now, beyond the use of diamond nanocrystals as fluorescence markers, nothing was known about the quantum behaviour of a NV probe in the complex room temperature extra-cellular environment. For the first time we explore in detail the quantum dynamics of a NV probe in proximity to the ion channel, lipid bilayer and surrounding aqueous environment. Our theoretical results indicate that real-time detection of ion channel operation at millisecond resolution is possible by directly monitoring the quantum decoherence of the NV probe. With the potential to scan and scale-up to an array-based system this conclusion may have wide ranging implications for nanoscale biology and drug discovery.Comment: 7 pages, 6 figure

    Nitric Oxide Signalling Augments Neuronal Voltage-Gated L-Type (CaV1) and P/Q-Type (CaV2.1) Channels in the Mouse Medial Nucleus of the Trapezoid Body

    Get PDF
    Nitric Oxide (NO) is a diffusible second messenger that modulates ion channels, intrinsic excitability and mediates synaptic plasticity. In light of its activity-dependent generation in the principal neurons of the medial nucleus of the trapezoid body (MNTB), we have investigated its potential modulatory effects on native voltage-gated calcium channels (CaV) within this nucleus. Whole-cell patch recordings were made from brain slices from P13–15 CBA mice. Slices were incubated with the inhibitor of neuronal nitric oxide synthase (nNOS) 7-nitroindazole (10 µM) and pharmacological blockers used to isolate Ca2+ current subtypes. Unpaired observations in the presence and absence of the NO-donors sodium nitroprusside (SNP, 100 µM) or Diethyl-ammonium-nonoate (DEA, 100 µM) were made to elucidate NO-dependent modulation of the expressed CaV subtypes. A differential effect of NO on the calcium channel subtypes was observed: CaV1 and CaV2.1 (L+R- and P/Q+R-type) conductances were potentiated, whereas N+R-type (CaV2.2) and R-type (CaV2.3) current amplitudes were unaffected. L+R-type currents increased from 0.36±0.04 nA to 0.64±0.11 nA and P/Q+R-type from 0.55±0.09 nA to 0.94±0.05 nA, thereby changing the balance and relative contribution of each subtype to the whole cell calcium current. In addition, N+R-type half-activation voltage was left shifted following NO exposure. NO-dependent modulation of P/Q+R and N+R-type, but not L+R-type, channels was removed by inhibition of soluble guanylyl cyclase (sGC) activity. This data demonstrates a differential effect of NO signalling on voltage-gated calcium entry, by distinct NO-dependent pathways

    Limited value of 18F-FDG PET/CT and S-100B tumour marker in the detection of liver metastases from uveal melanoma compared to liver metastases from cutaneous melanoma

    Get PDF
    Purpose: The objective of this study was to evaluate the value of 18F-FDG PET/CT and S-100B tumour marker for the detection of liver metastases from uveal melanoma in comparison to liver metastases from cutaneous melanoma. Methods: A retrospective evaluation was conducted of 27 liver metastases in 13 patients with uveal melanoma (UM) (mean age: 56.8, range: 30-77) and 43 liver metastases in 14 patients (mean age: 57.9, range: 40-82) with cutaneous melanoma (CM) regarding size and FDG uptake by measuring the maximum standardized uptake value (SUVmax). S-100B serum tumour markers were available in 20 patients. Cytology, histology, additional morphological imaging and follow-up served as reference standard. In nine patients liver metastases were further evaluated histologically regarding GLUT-1 and S-100 receptor expression and regarding epithelial or spindle cell growth pattern. Results: Of 27 liver metastases in 6 of 13 patients (46%) with UM, 16 (59%) were FDG negative, whereas all liver metastases from CM were positive. Liver metastases from UM showed significantly (p < 0.001) lower SUVmax (mean: 3.5, range: 1.5-13.4) compared with liver metastases from CM (mean: 6.6, range: 2.3-15.3). In four of six (66.7%) patients with UM and liver metastases S-100B was normal and in two (33.3%) increased. All PET-negative liver metastases were detectable by morphological imaging (CT or MRI). S-100B was abnormal in 13 of 14 patients with liver metastases from CM. S-100B values were significantly higher (p = 0.007) in the CM patient group (mean S-100B: 10.9μg/l, range: 0.1-115μg/l) compared with the UM patients (mean: 0.2μg/l, range: 0.0-0.5μg/l). Histological work-up of the liver metastases showed no obvious difference in GLUT-1 or S-100 expression between UM and CM liver metastases. The minority (36%) of patients with UM had extrahepatic metastases and the majority (86%) of patients with CM had extrahepatic metastases, respectively. There was a close to significant trend to better survival of UM patients compared with CM patients (p = 0.06). Conclusion: FDG PET/CT and serum S-100B are not sensitive enough for the detection of liver metastases from UM, whereas liver metastases from cutaneous melanoma are reliably FDG positive and lead regularly to increased S-100B tumour markers. The reason for the lower FDG uptake in UM liver metastases remains unclear. We recommend to perform combined contrast-enhanced PET/CT in order to detect FDG-negative liver metastases from U
    • …
    corecore