In-Stent CTO Percutaneous Coronary Intervention: Individual Patient Data Pooled Analysis of 4 Multicenter Registries
OBJECTIVES: The authors sought to examine the outcomes of percutaneous coronary intervention (PCI) for in-stent restenosis (ISR) chronic total occlusions (CTOs).
BACKGROUND: The outcomes of PCI for ISR CTOs have received limited study.
METHODS: The authors examined the clinical and angiographic characteristics and procedural outcomes of 11,961 CTO PCIs performed in 11,728 patients at 107 centers in Europe, North America, Latin America, and Asia between 2012 and 2020, pooling patient-level data from 4 multicenter registries. In-hospital major adverse cardiovascular events (MACE) included death, myocardial infarction, stroke, and tamponade. Long-term MACE were defined as the composite of all-cause death, myocardial infarction, and target vessel revascularization.
RESULTS: ISR represented 15% of the CTOs (n = 1,755). Patients with ISR CTOs had higher prevalence of diabetes (44% vs. 38%; p \u3c 0.0001) and prior coronary artery bypass graft surgery (27% vs. 24%; p = 0.03). Mean J-CTO (Multicenter CTO Registry in Japan) score was 2.32 ± 1.27 in the ISR group and 2.22 ± 1.27 in the de novo group (p = 0.01). Technical (85% vs. 85%; p = 0.75) and procedural (84% vs. 84%; p = 0.82) success was similar for ISR and de novo CTOs, as was the incidence of in-hospital MACE (1.7% vs. 2.2%; p = 0.25). Antegrade wiring was the most common successful strategy, in 70% of ISR and 60% of de novo CTOs, followed by retrograde crossing (16% vs. 23%) and antegrade dissection and re-entry (15% vs. 16%; p \u3c 0.0001). At 12 months, patients with ISR CTOs had a higher incidence of MACE (hazard ratio: 1.31; 95% confidence intervals: 1.01 to 1.70; p = 0.04).
CONCLUSIONS: ISR CTOs represent 15% of all CTO PCIs and can be recanalized with similar success and in-hospital MACE as de novo CTOs
Global Chronic Total Occlusion Crossing Algorithm: JACC State-of-the-Art Review
The authors developed a global chronic total occlusion crossing algorithm following 10 steps: 1) dual angiography; 2) careful angiographic review focusing on proximal cap morphology, occlusion segment, distal vessel quality, and collateral circulation; 3) approaching proximal cap ambiguity using intravascular ultrasound, retrograde, and move-the-cap techniques; 4) approaching poor distal vessel quality using the retrograde approach and bifurcation at the distal cap by use of a dual-lumen catheter and intravascular ultrasound; 5) feasibility of retrograde crossing through grafts and septal and epicardial collateral vessels; 6) antegrade wiring strategies; 7) retrograde approach; 8) changing strategy when failing to achieve progress; 9) considering performing an investment procedure if crossing attempts fail; and 10) stopping when reaching high radiation or contrast dose or in case of long procedural time, occurrence of a serious complication, operator and patient fatigue, or lack of expertise or equipment. This algorithm can improve outcomes and expand discussion, research, and collaboration
Global Chronic Total Occlusion Crossing Algorithm
The authors developed a global chronic total occlusion crossing algorithm following 10 steps: 1) dual angiography; 2) careful angiographic review focusing on proximal cap morphology, occlusion segment, distal vessel quality, and collateral circulation; 3) approaching proximal cap ambiguity using intravascular ultrasound, retrograde, and move-the-cap techniques; 4) approaching poor distal vessel quality using the retrograde approach and bifurcation at the distal cap by use of a dual-lumen catheter and intravascular ultrasound; 5) feasibility of retrograde crossing through grafts and septal and epicardial collateral vessels; 6) antegrade wiring strategies; 7) retrograde approach; 8) changing strategy when failing to achieve progress; 9) considering performing an investment procedure if crossing attempts fail; and 10) stopping when reaching high radiation or contrast dose or in case of long procedural time, occurrence of a serious complication, operator and patient fatigue, or lack of expertise or equipment. This algorithm can improve outcomes and expand discussion, research, and collaboration.info:eu-repo/semantics/publishedVersio
Recommended from our members
Guiding Principles for Chronic Total Occlusion Percutaneous Coronary Intervention.
Outcomes of chronic total occlusion (CTO) percutaneous coronary intervention (PCI) have improved because of advancements in equipment and techniques. With global collaboration and knowledge sharing, we have identified 7 common principles that are widely accepted as best practices for CTO-PCI.  1. Ischemic symptom improvement is the primary indication for CTO-PCI.  2. Dual coronary angiography and in-depth and structured review of the angiogram (and, if available, coronary computed tomography angiography) are key for planning and safely performing CTO-PCI.  3. Use of a microcatheter is essential for optimal guidewire manipulation and exchanges.  4. Antegrade wiring, antegrade dissection and reentry, and the retrograde approach are all complementary and necessary crossing strategies. Antegrade wiring is the most common initial technique, whereas retrograde and antegrade dissection and reentry are often required for more complex CTOs.  5. If the initially selected crossing strategy fails, efficient change to an alternative crossing technique increases the likelihood of eventual PCI success, shortens procedure time, and lowers radiation and contrast use.  6. Specific CTO-PCI expertise and volume and the availability of specialized equipment will increase the likelihood of crossing success and facilitate prevention and management of complications, such as perforation.  7. Meticulous attention to lesion preparation and stenting technique, often requiring intracoronary imaging, is required to ensure optimum stent expansion and minimize the risk of short- and long-term adverse events. These principles have been widely adopted by experienced CTO-PCI operators and centers currently achieving high success and acceptable complication rates. Outcomes are less optimal at less experienced centers, highlighting the need for broader adoption of the aforementioned 7 guiding principles along with the development of additional simple and safe CTO crossing and revascularization strategies through ongoing research, education, and training
Shell-and-tube ceramic heat exchangers for high-temperature GTEs applications
Communication to : 11th international heat transfer conference, Kyongju (Korea), August 25-28, 98SIGLEAvailable from INIST (FR), Document Supply Service, under shelf-number : 22419, issue : a.1998 n.182 / INIST-CNRS - Institut de l'Information Scientifique et TechniqueFRFranc
Upstream flow characterization of the AGATA catalytic combustor by 2 D LDV measurements
Communication to : 7th congress IGTC'99, Kobe (Japan), November 14-19, 1999SIGLEAvailable from INIST (FR), Document Supply Service, under shelf-number : 22419, issue : a.1999 n.200 / INIST-CNRS - Institut de l'Information Scientifique et TechniqueFRFranc
Facilities for automotive gas turbine ceramic components
Communication to : 42nd ASME gas turbine and aeroengine congress,= Orlando, FL (USA), June 2-5, 1997Available from INIST (FR), Document Supply Service, under shelf-number : 22419, issue : a.1997 n.69 / INIST-CNRS - Institut de l'Information Scientifique et TechniqueSIGLEFRFranc
Optimization of design of high pressure compact and light-weight liquid heat exchangers