3 research outputs found

    Functionalized Silver Nanoparticle-Decorated Paper Sensor for Rapid Colorimetric Detection of Copper Ions in Water

    No full text
    Copper contamination to water bodies is an environmental concern of significant risk due to its harmful effect on aquatic life forms and human beings. Herein, a paper-based colorimetric sensor was fabricated by immobilizing polyethyleneimine-capped silver nanoparticles (PEI-AgNPs) on commercial filter paper. The sensitivity and selectivity of the paper-based sensor\u27s colorimetric response to copper ions in water were investigated. PEI-AgNPs with an average diameter of 12.66 ± 4.07 nm were successfully immobilized on the filter paper by the simple dipping technique, as evidenced by the scanning electron microscopy with energy-dispersive x-ray result. A color change from pale yellow to dark yellow green was noted after exposing the paper sensor in a water sample with copper ions. This colorimetric response was exclusively observed for copper ions only, suggesting the selectivity of the paper sensor towards copper ions. Moreover, ultraviolet–visible spectroscopy results revealed that the detection limit of the paper sensor was observed to about 1.0 ppm. Meanwhile, color analysis on the sensor\u27s digital images revealed the linear response of the sensor with decreasing copper ion concentration down to 1.0 ppm. The selectivity of the sensor was also observed by the color intensity profile of the sensor. This work presents promising results that can be utilized as a reference for developing affordable, fast, portable, and reliable sensing devices for on-site water quality monitoring and other applications

    Preparation of Spin-Coated Poly(vinyl alcohol)/ chitosan/ Gold Nanoparticles Composite and Its Potential for Colorimetric Detection of Cyanide in Water

    No full text
    The rampant use of cyanide in mining activities has posed a substantial hazard to aquatic ecosystems and human health. Herein, a composite film of poly(vinyl alcohol)/chitosan (PVA/CS) with gold nanoparticles was synthesized as a potential colorimetric sensor for cyanide ions detection in water. The utilized AuNPs with a mean diameter of 14.32±3.49 nm were synthesized by chemical reduction using polyethyleneimine. Ultraviolet-visible spectroscopy revealed the characteristic peak of AuNPs at around 530 nm in the spectrum of PVA/CS/AuNP film, while SEM microscopy revealed the integration AuNPs across the polymer substrate. A color change from red to colorless was observed on the composite film after the addition of water samples with cyanide ions with a visual detection limit between 0.1-1 ppm. The sensor also exhibited good selectivity towards cyanide against the tested water samples containing various metal ions. This study reveals the potential of the fabricated PVA/CS/AuNP composite film as a simple, affordable, and environmentally benign material for on-site detection of cyanide in water and other related application

    Delayed colorectal cancer care during covid-19 pandemic (decor-19). Global perspective from an international survey

    No full text
    Background The widespread nature of coronavirus disease 2019 (COVID-19) has been unprecedented. We sought to analyze its global impact with a survey on colorectal cancer (CRC) care during the pandemic. Methods The impact of COVID-19 on preoperative assessment, elective surgery, and postoperative management of CRC patients was explored by a 35-item survey, which was distributed worldwide to members of surgical societies with an interest in CRC care. Respondents were divided into two comparator groups: 1) ‘delay’ group: CRC care affected by the pandemic; 2) ‘no delay’ group: unaltered CRC practice. Results A total of 1,051 respondents from 84 countries completed the survey. No substantial differences in demographics were found between the ‘delay’ (745, 70.9%) and ‘no delay’ (306, 29.1%) groups. Suspension of multidisciplinary team meetings, staff members quarantined or relocated to COVID-19 units, units fully dedicated to COVID-19 care, personal protective equipment not readily available were factors significantly associated to delays in endoscopy, radiology, surgery, histopathology and prolonged chemoradiation therapy-to-surgery intervals. In the ‘delay’ group, 48.9% of respondents reported a change in the initial surgical plan and 26.3% reported a shift from elective to urgent operations. Recovery of CRC care was associated with the status of the outbreak. Practicing in COVID-free units, no change in operative slots and staff members not relocated to COVID-19 units were statistically associated with unaltered CRC care in the ‘no delay’ group, while the geographical distribution was not. Conclusions Global changes in diagnostic and therapeutic CRC practices were evident. Changes were associated with differences in health-care delivery systems, hospital’s preparedness, resources availability, and local COVID-19 prevalence rather than geographical factors. Strategic planning is required to optimize CRC care
    corecore