5 research outputs found

    Evaluation of Interferon-Gamma Release Assays in the Diagnosis of Recent Tuberculosis Infection in Health Care Workers

    Get PDF
    BACKGROUND:Health care workers (HCWs) are a group at risk of latent tuberculosis infection (LTBI). The aims of this study were to determine IFN-gamma response by QuantiFERON-TB GOLD In Tube (QFN-G-IT) and T-SPOT.TB in HCWs, comparing the results with tuberculin skin test (TST); and to analyze the capacity of IFN-gamma tests to detect recent versus remote LTBI with a prolonged stimulation test (PST). METHODOLOGY/PRINCIPAL FINDINGS:A total of 147 HCWs were enrolled; 23 of whom were BCG vaccinated. 95 HCWs (64.6%) had a previous positive TST and were not retested; and 52 HCWs had a previous negative TST or were tested for the first time. When we analysed individuals without previous positive TST, the number of positive results for T-SPOT.TB was 12/52 (23.1%); and for QFN-G-IT, 9/52 (17.3%). The global concordance (kappa) between T-SPOT.TB and QFN-G-IT with TST was 0.754 and 0.929 respectively. Of individuals with previous positive TST, T-SPOT.TB and QFN-G-IT were negative in 51.6% (49/95) and 62.1% (59/95) respectively, decreasing the concordance to 0.321 and 0.288, respectively. In non-BCG vaccinated HCWs with previous positive TST a positive IFN-gamma test was associated with degree of exposure and diameter of TST. PST was performed in 24 HCW with previous positive TST and negative IFN-gamma tests. PST was developed in 3 cell cultures stimulated with medium alone, ESAT-6 and CFP-10, respectively. In the third and sixth day of incubation period, part of the supernatants were replaced with complete medium supplemented with (rIL)-2. On day 9, ELISPOT assay was performed. In 14 samples PST was not valid due to not having enough cells. In 8 cases, the response was negative, and in 2 cases positive, suggesting that these patients were infected with Mycobacterium tuberculosis in some point in the past. CONCLUSIONS:Both IFN-gamma tests showed a similar number of positive results, and concordance between the tests was excellent. None of the tests was affected by prior BCG vaccination. IFN-gamma tests are a useful tool for detecting recent infection in HCW population

    Direct Identification of Urinary Tract Pathogens from Urine Samples, Combining Urine Screening Methods and Matrix-Assisted Laser Desorption Ionization–Time of Flight Mass Spectrometry

    No full text
    Early diagnosis of urinary tract infections (UTIs) is essential to avoid inadequate or unnecessary empirical antibiotic therapy. Microbiological confirmation takes 24 to 48 h. The use of screening methods, such as cytometry and automated microscopic analysis of urine sediment, allows the rapid prediction of negative samples. In addition, matrix-assisted laser desorption ioniza- tion–time of flight mass spectrometry (MALDI-TOF MS) is a widely established technique in clinical microbiology laboratories used to identify microorganisms. We evaluated the ability of MALDI-TOF MS to identify microorganisms from direct urine samples and the predictive value of automated analyzers for the identification of microorganisms in urine by MALDI-TOF MS. A total of 451 urine samples from patients with suspected UTIs were first analyzed using the Sysmex UF-1000i flow cytometer, an automatic sediment analyzer with microscopy (SediMax), culture, and then processed by MALDI-TOF MS with a simple triple- centrifuged procedure to obtain a pellet that was washed and centrifuged and finally applied directly to the MALDI-TOF MS plate. The organisms in 336 samples were correctly identified, mainly those with Gram-negative bacteria (86.10%). No microor- ganisms were misidentified, and no Candida spp. were correctly identified. Regarding the data from autoanalyzers, the best bac- teriuria cutoffs were 1,000 and 200 U/l for UF-1000i and SediMax, respectively. It was concluded that the combination of a urine screening method and MALDI-TOF MS provided a reliable identification from urine samples, especially in those contain- ing Gram-negative bacteria

    Evaluation of the SediMax automated microscopy sediment analyzer and the Sysmex UF-1000i flow cytometer as screening tools to rule out negative urinary tract infections

    No full text
    Urinary tract infections (UTI) are highly prevalent in nosocomial and community settings, and their diagnosis is costly and time-consuming. Screening methods represent an important advance towards the final UTI diagnosis, diminishing inappropriate treatment or clinical complications. Automated analyzers have been developed and commercialized to screen and rule out negative urine samples. The aim of this study was to evaluate two of these automated analyzers (SediMax, an automatic sediment analyzer and UF-1000i a flow cytometer) to predict negative urine cultures. A total of 1934 urine samples were analyzed. A very strong correlation for white blood cells (WBC) (rs: 0.928) and a strong correlation for bacteria (BAC) (rs: 0.693) were obtained. We also calculated optimal cut-off points for both autoanalyzers: 18 WBC/μL and 97 BAC/μL for SediMax (sensitivity = 96.25%, specificity = 63.04%, negative predictive value = 97.97%), and 40 WBC/μL and 460 BAC/μL for UF-1000i (sensitivity = 98.13%, specificity = 79.16%, negative predictive value = 99.18%). The use of SediMax and UF- 1000i resulted in a 46.33% and 57.19% reduction of all samples cultured, respectively. In conclusion, both ana- lyzers are good UTI screening tools in our setting

    Drivers of Productivity in the Spanish Banking Sector: Recent Evidence

    No full text
    corecore