8 research outputs found
Correction to Recommendation of RILEM TC 264 RAP on the evaluation of asphalt recycling agents for hot mix asphalt (Materials and Structures, (2022), 55, 2, (31), 10.1617/s11527-021-01837-0)
Publisher Copyright: © The Author(s) 2022.In this article the affiliation details for A. Kawakami were incorrectly given as ‘‘Department of Biological Information, Tokyo Institute of Technology, 4259 Nagatsuta, Midori-ku, Yokohama 226-8501, Japan’’ but should have been ‘‘Pavement Research Team, Public Works Research Institute, 1-6 Minamihara, Tsukuba-shi, Ibaraki-ken 305-8516, Japan’’. The original article has been corrected.Peer reviewe
Recommendation of RILEM TC 264 RAP on the evaluation of asphalt recycling agents for hot mix asphalt
This recommendation is based on the results of an inter-laboratory study organised by the RILEM technical committee TC 264-RAP ‘‘Asphalt Pavement Recycling’’—Task Group 3 (TG3) focusing on Asphalt Binder for Recycled Asphalt Mixture. The TG3 aimed to evaluate the effect of a specific family of materials known as asphalt recycling agent (ARA) on the aged binder under different configurations. Even though ageing is an irreversible phenomenon, effective ARA must have the capability to improve the flexibility of the bituminous materials and their resistance against cracking susceptibility with no adverse effect on the rutting resistance of pavements containing reclaimed asphalt. A total of 17 participating laboratories analysed the properties of binder blends composed of aged binder from reclaimed asphalt in three different contents (60, 80, 100%), ARA and virgin binder. The physical properties of the blends were thoroughly evaluated through traditional and rheological binder testing. This recommendation proposes to restore the original material properties at low and intermediate temperatures (i.e. cracking resistance) while balancing the high-temperature characteristics (i.e. rutting susceptibility) with durable impact throughout the progression of ageing phenomena. Therefore, useing of the Dynamic Shear Rheometer is foreseen as a more suitable and sustainable means to evaluate binder blends containing an asphalt recycling agent. Compared with conventional testing, the proposed approach requires fewer materials while resulting in a faster experimental procedure with one single test
Recommendation of RILEM TC 264 RAP on the evaluation of asphalt recycling agents for hot mix asphalt
Recommendation of RILEM TC 264 RAP on the evaluation of asphalt recycling agents for hot mix asphalt
This recommendation is based on the results of an inter-laboratory study organised by the RILEM technical committee TC 264-RAP "Asphalt Pavement Recycling"—Task Group 3 (TG3) focusing on Asphalt Binder for Recycled Asphalt Mixture. The TG3 aimed to evaluate the effect of a specific family of materials known as asphalt recycling agent (ARA) on the aged binder under different configurations. Even though ageing is an irreversible phenomenon, effective ARA must have the capability to improve the flexibility of the bituminous materials and their resistance against cracking susceptibility with no adverse effect on the rutting resistance of pavements containing reclaimed asphalt. A total of 17 participating laboratories analysed the properties of binder blends composed of aged binder from reclaimed asphalt in three different contents (60, 80, 100%), ARA and virgin binder. The physical properties of the blends were thoroughly evaluated through traditional and rheological binder testing. This recommendation proposes to restore the original material properties at low and intermediate temperatures (i.e. cracking resistance) while balancing the high-temperature characteristics (i.e. rutting susceptibility) with durable impact throughout the progression of ageing phenomena. Therefore, using of the Dynamic Shear Rheometer is foreseen as a more suitable and sustainable means to evaluate binder blends containing an asphalt recycling agent. Compared with conventional testing, the proposed approach requires fewer materials while resulting in a faster experimental procedure with one single test
Effect of Aging on the Rheological Properties of Blends of Virgin and Rejuvenated RA Binders
The use of rejuvenators has seen a consistent increase over the years in the asphalt pavement industry. This is due to the need for maximizing the demand for incorporating a higher amount of Reclaimed Asphalt (RA) in the pavement asphalt mixtures. In order to tackle this challenge, the Task Group 3, focusing on asphalt binders and additives, of the RILEM TC RAP conducted an interlaboratory activity to evaluate the effect of aging on blends of virgin and rejuvenated RA binders. A set of conventional tests including penetration value at 25 °C, softening point temperature and rheological measurements by means of Dynamic Shear Rheometer (DSR) were selected to involve a large number of participants. A binder, recovered from field RA, was treated with a bio-based rejuvenator and blended with a virgin binder to simulate recycling at three different percentages 60, 80, and 100%. These blends, as well as the pure virgin binder, were next short and long term aged and tested to evaluate the changes in the corresponding properties. Relatively consistent results were obtained for the entire set of blends. The aging of combined rejuvenated RA and virgin binders was comparable to that experienced for the pure virgin binder. DSR data provided a more precise evolution of the impact of aging on the materials
Effect of Aging on the Rheological Properties of Blends of Virgin and Rejuvenated RA Binders
The use of rejuvenators has seen a consistent increase over the years in the asphalt pavement industry. This is due to the need for maximizing the demand for incorporating a higher amount of Reclaimed Asphalt (RA) in the pavement asphalt mixtures. In order to tackle this challenge, the Task Group 3, focusing on asphalt binders and additives, of the RILEM TC RAP conducted an interlaboratory activity to evaluate the effect of aging on blends of virgin and rejuvenated RA binders. A set of conventional tests including penetration value at 25 °C, softening point temperature and rheological measurements by means of Dynamic Shear Rheometer (DSR) were selected to involve a large number of participants. A binder, recovered from field RA, was treated with a bio-based rejuvenator and blended with a virgin binder to simulate recycling at three different percentages 60 %, 80 %, and 100 %. These blends, as well as the pure virgin binder, were next short and long term aged and tested to evaluate the changes in the corresponding properties. Relatively consistent results were obtained for the entire set of blends. The aging of combined rejuvenated RA and virgin binders was comparable to that experienced for the pure virgin binder. DSR data provided a more precise evolution of the impact of aging on the materials