12 research outputs found

    Multistrip multigap symmetric RPC

    Get PDF
    Abstract The characteristics of a symmetric multigap resistive plate chamber with multistrip readout electrode, recently developed by us, continued to be investigated. Studies of the time resolution, efficiency, average charge and dark rate as a function of applied voltage and the influence of the angle of incidence of the detected particle on these observables have been performed. Different type of discriminators have been tested

    A large-area glass-resistive plate chamber with multistrip readout

    Get PDF
    Abstract A completely new configuration of a glass resistive-plate chamber (GRPC) was built and tested. It consists of a double two-gap structure of electrodes with an active area of about 400 cm 2 and is read out via a central multistrip printed circuit board. In measurements with a 60 Co source and p, d particles of 1.5 A GeV time resolutions better than 80 ps , position resolution along the strips of 5– 6 mm and efficiencies larger than 95% were obtained using available fast standard electronics. These results open the possibility of constructing compact TOF detectors of high resolution and high granularity

    Status Report on the ALICE Prototype TPC with Ring-Cathode Readout

    Full text link
    o a single ASIC, thus allowing later on-detector installation. For the transfer of the data a newly developed full duplex optical data link was used. Details of the detector design, construction and readout are presented together with results from bench and beam tests. </HTML
    corecore