290 research outputs found

    Analytical and clinical evaluation of DiaSorin LiaisonÂź Calprotectin fecal assay adapted for serum samples

    Full text link
    Background Calprotectin is a calcium-binding protein that can be measured in serum, plasma, and feces. Increased serum and plasma calprotectin concentrations have been found in chronic inflammatory rheumatic disorders. An analytical and clinical evaluation of the DiaSorin Liaison (R) fecal Calprotectin assay using LIAISON (R) XL was performed. Methods The protocol included an analytical and clinical evaluation in which imprecision, the linearity of dilution, differences between serum and plasma samples and method comparison with CalproLab (TM) ELISA kit were assessed. Serum calprotectin concentrations in active (n = 26) and remission (n = 23) rheumatoid arthritis (RA) patients were compared. Results The intra-day and inter-day analytical imprecision CVs ranged from 2.9% to 4.0% and 2.7% to 10.4%, respectively. Correlation between measured and expected values was high (R > 0.99), indicating good linearity. The Wilcoxon signed-rank test showed that serum and plasma matched samples presented statistically significant differences (p < 0.001) being the highest concentrations of calprotectin observed in serum samples. Deming regression equation was as follows: Diasorin calprotectin (mu g/ml) = -0.32 (95% CI: -0.65 - -0.05) +1.58 (95% CI: 1.42-1.79).* Calprolab calprotectin (mu g/ml). Significantly higher serum calprotectin levels were found in RA patients with active disease when compared to patients with low disease activity or in clinical remission (mean +/- SD) [(3.35 mu g/ml +/- 1.55) vs. (1.63 mu g/ml +/- 0.52), p < 0.001] and these levels correlated well with all disease activity indices. Conclusions The DiaSorin Liaison (R) fecal Calprotectin assay adapted for serum samples showed adequate technical performances and the clinical performances were similar to other assays

    Plasma calprotectin as a biomarker of ultrasound synovitis in rheumatoid arthritis patients receiving IL-6 antagonists or JAK inhibitors

    Full text link
    To analyse the accuracy of plasma calprotectin in patients with rheumatoid arthritis (RA) receiving monoclonal antibodies against IL-6 receptors (anti-rIL-6) or JAK inhibitors (JAKis) in detecting ultrasound (US) synovitis and compare it with acute phase reactants [high-sensitivity C-reactive protein (hs-CRP) and ESR].An observational cross-sectional study of RA patients receiving anti-rIL-6 (tocilizumab or sarilumab) or JAKi, (baricitinib or tofacitinib) was made. Plasma calprotectin for the diagnosis of US synovitis [synovial hypertrophy grade (SH)???2 plus power Doppler signal (PD)???1] was analysed using receiver operating characteristic curves (ROCs). The performance of ESR and hs-CRP was also studied. The three ROC curves were compared to determine which had the highest discriminatory power. Associations between plasma calprotectin and US scores were made using correlation analysis.Sixty-three RA patients were included. Mean plasma calprotectin levels were significantly higher in patients with US synovitis than in those without (0.89?±?0.85 vs 0.30?±?0.12 ?g/ml; p?=?0.0003). A moderate correlation between calprotectin and all US scores (HS score Rho?=?0.479; PD score Rho?=?0.492; and global score Rho?=?0.495) was found. The discriminatory capacity of plasma calprotectin showed an AUC of 0.795 (95% CI: 0.687-0.904). The AUC of hs-CRP and ESR was 0.721 and 0.564, respectively. hs-CRP serum levels showed a low positive correlation with the three US scores (Rho?<?0.40). After analysis according to the drugs administered, the correlation disappeared in patients receiving anti-rIL-6.Plasma calprotectin may be a sensitive biomarker of synovial inflammation in RA patients treated with anti-rIL-6 or JAKi.© The Author(s), 2022

    Synaptic, axonal damage and inflammatory cerebrospinal fluid biomarkers in neurodegenerative dementias

    Get PDF
    INTRODUCTION: Synaptic damage, axonal neurodegeneration, and neuroinflammation are common features in Alzheimer's disease (AD), frontotemporal dementia (FTD), and Creutzfeldt-Jakob disease (CJD). METHODS: Unicentric cohort of 353 participants included healthy control (HC) subjects, AD continuum stages, genetic AD and FTD, and FTD and CJD. We measured cerebrospinal fluid neurofilament light (NF-L), neurogranin (Ng), 14-3-3, and YKL-40 proteins. RESULTS: Biomarkers showed differences in HC subjects versus AD, FTD, and CJD. Disease groups differed between them except AD versus FTD for YKL-40. Only NF-L differed between all stages within the AD continuum. AD and FTD symptomatic mutation carriers presented differences with respect to HC subjects. Applying the AT(N) system, 96% subjects were positive for neurodegeneration if 14-3-3 was used, 94% if NF-L was used, 62% if Ng was used, and 53% if YKL-40 was used. DISCUSSION: Biomarkers of synapse and neurodegeneration differentiate HC subjects from neurodegenerative dementias and between AD, FTD, and CJD. NF-L and 14-3-3 performed similar to total tau when AT(N) system was applied

    Faecal immunochemical tests (FIT) can help to rule out colorectal cancer in patients presenting in primary care with lower abdominal symptoms:a systematic review conducted to inform new NICE DG30 diagnostic guidance

    Get PDF
    __Background:__ This study has attempted to assess the effectiveness of quantitative faecal immunochemical tests (FIT) for triage of people presenting with lower abdominal symptoms, where a referral to secondary care for investigation of suspected colorectal cancer (CRC) is being considered, particularly when the 2-week criteria are not met. __Methods:__ We conducted a systematic review following published guidelines for systematic reviews of diagnostic tests. Twenty-one resources were searched up until March 2016. Summary estimates were calculated using a bivariate model or a random-effects logistic regression model. __Results:__ Nine studies are included in this review. One additional study, included in our systematic review, was provided as 'academic in confidence' and cannot be described herein. When FIT was based on a single faecal sample and a cut-off of 10 ÎŒg Hb/g faeces, sensitivity estimates indicated that a negative result using either the OC-Sensor or HM-JACKarc may be adequate to rule out nearly all CRC; the summary estimate of sensitivity for the OC-Sensor was 92.1%, based on four studies, and the only study of HM-JACKarc to assess the 10 ÎŒg Hb/g faeces cut-off reported a sensitivity of 100%. The corresponding specificity estimates were 85.8% (95% CI 78.3-91.0%) and 76.6%, respectively. When the diagnostic criterion was changed to include lower grades of neoplasia, i.e. the target condition included higher risk adenoma (HRA) as well as CRC, the rule-out performance of both FIT assays was reduced. __Conclusions:__ There is evidence to suggest that triage using FIT at a cut-off around 10 ÎŒg Hb/g faeces has the potential to correctly rule out CRC and avoid colonoscopy in 75-80% of symptomatic patients. Systematic review registration: PROSPERO 4201603772

    Jet energy measurement with the ATLAS detector in proton-proton collisions at root s=7 TeV

    Get PDF
    The jet energy scale and its systematic uncertainty are determined for jets measured with the ATLAS detector at the LHC in proton-proton collision data at a centre-of-mass energy of √s = 7TeV corresponding to an integrated luminosity of 38 pb-1. Jets are reconstructed with the anti-kt algorithm with distance parameters R=0. 4 or R=0. 6. Jet energy and angle corrections are determined from Monte Carlo simulations to calibrate jets with transverse momenta pT≄20 GeV and pseudorapidities {pipe}η{pipe}<4. 5. The jet energy systematic uncertainty is estimated using the single isolated hadron response measured in situ and in test-beams, exploiting the transverse momentum balance between central and forward jets in events with dijet topologies and studying systematic variations in Monte Carlo simulations. The jet energy uncertainty is less than 2. 5 % in the central calorimeter region ({pipe}η{pipe}<0. 8) for jets with 60≀pT<800 GeV, and is maximally 14 % for pT<30 GeV in the most forward region 3. 2≀{pipe}η{pipe}<4. 5. The jet energy is validated for jet transverse momenta up to 1 TeV to the level of a few percent using several in situ techniques by comparing a well-known reference such as the recoiling photon pT, the sum of the transverse momenta of tracks associated to the jet, or a system of low-pT jets recoiling against a high-pT jet. More sophisticated jet calibration schemes are presented based on calorimeter cell energy density weighting or hadronic properties of jets, aiming for an improved jet energy resolution and a reduced flavour dependence of the jet response. The systematic uncertainty of the jet energy determined from a combination of in situ techniques is consistent with the one derived from single hadron response measurements over a wide kinematic range. The nominal corrections and uncertainties are derived for isolated jets in an inclusive sample of high-pT jets. Special cases such as event topologies with close-by jets, or selections of samples with an enhanced content of jets originating from light quarks, heavy quarks or gluons are also discussed and the corresponding uncertainties are determined. © 2013 CERN for the benefit of the ATLAS collaboration

    Measurement of the inclusive and dijet cross-sections of b-jets in pp collisions at sqrt(s) = 7 TeV with the ATLAS detector

    Get PDF
    The inclusive and dijet production cross-sections have been measured for jets containing b-hadrons (b-jets) in proton-proton collisions at a centre-of-mass energy of sqrt(s) = 7 TeV, using the ATLAS detector at the LHC. The measurements use data corresponding to an integrated luminosity of 34 pb^-1. The b-jets are identified using either a lifetime-based method, where secondary decay vertices of b-hadrons in jets are reconstructed using information from the tracking detectors, or a muon-based method where the presence of a muon is used to identify semileptonic decays of b-hadrons inside jets. The inclusive b-jet cross-section is measured as a function of transverse momentum in the range 20 < pT < 400 GeV and rapidity in the range |y| < 2.1. The bbbar-dijet cross-section is measured as a function of the dijet invariant mass in the range 110 < m_jj < 760 GeV, the azimuthal angle difference between the two jets and the angular variable chi in two dijet mass regions. The results are compared with next-to-leading-order QCD predictions. Good agreement is observed between the measured cross-sections and the predictions obtained using POWHEG + Pythia. MC@NLO + Herwig shows good agreement with the measured bbbar-dijet cross-section. However, it does not reproduce the measured inclusive cross-section well, particularly for central b-jets with large transverse momenta.Comment: 10 pages plus author list (21 pages total), 8 figures, 1 table, final version published in European Physical Journal

    Search for the neutral Higgs bosons of the minimal supersymmetric standard model in pp collisions at root s=7 TeV with the ATLAS detector

    Get PDF
    A search for neutral Higgs bosons of the Minimal Supersymmetric Standard Model (MSSM) is reported. The analysis is based on a sample of proton-proton collisions at a centre-of-mass energy of 7TeV recorded with the ATLAS detector at the Large Hadron Collider. The data were recorded in 2011 and correspond to an integrated luminosity of 4.7 fb-1 to 4.8 fb-1. Higgs boson decays into oppositely-charged muon or τ lepton pairs are considered for final states requiring either the presence or absence of b-jets. No statistically significant excess over the expected background is observed and exclusion limits at the 95% confidence level are derived. The exclusion limits are for the production cross-section of a generic neutral Higgs boson, φ, as a function of the Higgs boson mass and for h/A/H production in the MSSM as a function of the parameters mA and tan ÎČ in the mhmax scenario for mA in the range of 90GeV to 500 GeV. Copyright CERN

    Observation of associated near-side and away-side long-range correlations in √sNN=5.02  TeV proton-lead collisions with the ATLAS detector

    Get PDF
    Two-particle correlations in relative azimuthal angle (Δϕ) and pseudorapidity (Δη) are measured in √sNN=5.02  TeV p+Pb collisions using the ATLAS detector at the LHC. The measurements are performed using approximately 1  Όb-1 of data as a function of transverse momentum (pT) and the transverse energy (ÎŁETPb) summed over 3.1<η<4.9 in the direction of the Pb beam. The correlation function, constructed from charged particles, exhibits a long-range (2<|Δη|<5) “near-side” (Δϕ∌0) correlation that grows rapidly with increasing ÎŁETPb. A long-range “away-side” (Δϕ∌π) correlation, obtained by subtracting the expected contributions from recoiling dijets and other sources estimated using events with small ÎŁETPb, is found to match the near-side correlation in magnitude, shape (in Δη and Δϕ) and ÎŁETPb dependence. The resultant Δϕ correlation is approximately symmetric about π/2, and is consistent with a dominant cos⁥2Δϕ modulation for all ÎŁETPb ranges and particle pT

    Measurement of the cross-section of high transverse momentum vector bosons reconstructed as single jets and studies of jet substructure in pp collisions at √s = 7 TeV with the ATLAS detector

    Get PDF
    This paper presents a measurement of the cross-section for high transverse momentum W and Z bosons produced in pp collisions and decaying to all-hadronic final states. The data used in the analysis were recorded by the ATLAS detector at the CERN Large Hadron Collider at a centre-of-mass energy of √s = 7 TeV;{\rm Te}{\rm V}andcorrespondtoanintegratedluminosityof and correspond to an integrated luminosity of 4.6\;{\rm f}{{{\rm b}}^{-1}}.ThemeasurementisperformedbyreconstructingtheboostedWorZbosonsinsinglejets.ThereconstructedjetmassisusedtoidentifytheWandZbosons,andajetsubstructuremethodbasedonenergyclusterinformationinthejetcentre−of−massframeisusedtosuppressthelargemulti−jetbackground.Thecross−sectionforeventswithahadronicallydecayingWorZboson,withtransversemomentum. The measurement is performed by reconstructing the boosted W or Z bosons in single jets. The reconstructed jet mass is used to identify the W and Z bosons, and a jet substructure method based on energy cluster information in the jet centre-of-mass frame is used to suppress the large multi-jet background. The cross-section for events with a hadronically decaying W or Z boson, with transverse momentum {{p}_{{\rm T}}}\gt 320\;{\rm Ge}{\rm V}andpseudorapidity and pseudorapidity |\eta |\lt 1.9,ismeasuredtobe, is measured to be {{\sigma }_{W+Z}}=8.5\pm 1.7$ pb and is compared to next-to-leading-order calculations. The selected events are further used to study jet grooming techniques

    Search for R-parity-violating supersymmetry in events with four or more leptons in sqrt(s) =7 TeV pp collisions with the ATLAS detector

    Get PDF
    A search for new phenomena in final states with four or more leptons (electrons or muons) is presented. The analysis is based on 4.7 fb−1 of s=7  TeV \sqrt{s}=7\;\mathrm{TeV} proton-proton collisions delivered by the Large Hadron Collider and recorded with the ATLAS detector. Observations are consistent with Standard Model expectations in two signal regions: one that requires moderate values of missing transverse momentum and another that requires large effective mass. The results are interpreted in a simplified model of R-parity-violating supersymmetry in which a 95% CL exclusion region is set for charged wino masses up to 540 GeV. In an R-parity-violating MSUGRA/CMSSM model, values of m 1/2 up to 820 GeV are excluded for 10 < tan ÎČ < 40
    • 

    corecore