1,704 research outputs found

    Influence of speed of sample processing on placental energetics and signalling pathways: implications for tissue collection.

    Get PDF
    INTRODUCTION: The placenta is metabolically highly active due to extensive endocrine and active transport functions. Hence, placental tissues soon become ischaemic after separation from the maternal blood supply. Ischaemia rapidly depletes intracellular ATP, and leads to activation of stress-response pathways aimed at reducing metabolic demands and conserving energy resources for vital functions. Therefore, this study aimed to elucidate the effects of ischaemia ex vivo as may occur during tissue collection on phosphorylation of placental proteins and kinases involved in growth and cell survival, and on mitochondrial complexes. METHODS: Eight term placentas obtained from normotensive non-laboured elective caesarean sections were kept at room-temperature and sampled at 10, 20, 30 and 45 min after delivery. Samples were analyzed by Western blotting. RESULTS: Between 10 and 45 min the survival signalling pathway intermediates, P-AKT, P-GSK3α and β, P-4E-BP1 and P-p70S6K were reduced by 30-65%. Stress signalling intermediates, P-eIF2α increased almost 3 fold after 45 min. However, other endoplasmic reticulum stress markers and the Heat Shock Proteins, HSP27, HSP70 and HSP90, did not change. Phosphorylation of AMPK, an energy sensor, was elevated 2 fold after 45 min. Contemporaneously, there was an ∼25% reduction in mitochondrial complex IV subunit I. DISCUSSION AND CONCLUSIONS: These results suggest that for placental signalling studies, samples should be taken and processed within 10 min of caesarean delivery to minimize the impact of ischaemia on protein phosphorylation

    Spatiotemporal evaluation of EMEP4UK-WRF v4.3 atmospheric chemistry transport simulations of health-related metrics for NO2, O3, PM10 and PM2.5 for 2001-2010

    Get PDF
    This study was motivated by the use in air pollution epidemiology and health burden assessment of data simulated at 5 km  ×  5 km horizontal resolution by the EMEP4UK-WRF v4.3 atmospheric chemistry transport model. Thus the focus of the model–measurement comparison statistics presented here was on the health-relevant metrics of annual and daily means of NO2, O3, PM2. 5, and PM10 (daily maximum 8 h running mean for O3). The comparison was temporally and spatially comprehensive, covering a 10-year period (2 years for PM2. 5) and all non-roadside measurement data from the UK national reference monitor network, which applies consistent operational and QA/QC procedures for each pollutant (44, 47, 24, and 30 sites for NO2, O3, PM2. 5, and PM10, respectively). Two important statistics highlighted in the literature for evaluation of air quality model output against policy (and hence health)-relevant standards – correlation and bias – together with root mean square error, were evaluated by site type, year, month, and day-of-week. Model–measurement statistics were generally better than, or comparable to, values that allow for realistic magnitudes of measurement uncertainties. Temporal correlations of daily concentrations were good for O3, NO2, and PM2. 5 at both rural and urban background sites (median values of r across sites in the range 0.70–0.76 for O3 and NO2, and 0.65–0.69 for PM2. 5), but poorer for PM10 (0.47–0.50). Bias differed between environments, with generally less bias at rural background sites (median normalized mean bias (NMB) values for daily O3 and NO2 of 8 and 11 %, respectively). At urban background sites there was a negative model bias for NO2 (median NMB  =  −29 %) and PM2. 5 (−26 %) and a positive model bias for O3 (26 %). The directions of these biases are consistent with expectations of the effects of averaging primary emissions across the 5 km  ×  5 km model grid in urban areas, compared with monitor locations that are more influenced by these emissions (e.g. closer to traffic sources) than the grid average. The biases are also indicative of potential underestimations of primary NOx and PM emissions in the model, and, for PM, with known omissions in the model of some PM components, e.g. some components of wind-blown dust. There were instances of monthly and weekday/weekend variations in the extent of model–measurement bias. Overall, the greater uniformity in temporal correlation than in bias is strongly indicative that the main driver of model–measurement differences (aside from grid versus monitor spatial representivity) was inaccuracy of model emissions – both in annual totals and in the monthly and day-of-week temporal factors applied in the model to the totals – rather than simulation of atmospheric chemistry and transport processes. Since, in general for epidemiology, capturing correlation is more important than bias, the detailed analyses presented here support the use of data from this model framework in air pollution epidemiology

    Self-Navigated Tissue Phase Mapping Using a Golden-Angle Spiral Acquisition-Proof of Concept in Patients with Pulmonary Hypertension

    Get PDF
    Purpose To create a high temporal- and spatial-resolution retrospectively cardiac-gated, tissue phase mapping (TPM) sequence, using an image-based respiratory navigator calculated from the data itself. Methods The sequence was based on a golden-angle spiral acquisition. Reconstruction of real-time images allowed creation of an image-based navigator. The expiratory spiral interleaves were then retrospectively cardiac-gated using data binning. TPM data were acquired in 20 healthy volunteers and 10 patients with pulmonary hypertension. Longitudinal and radial myocardial velocities were calculated in the left ventricle and right ventricle. Results The image-based navigator was shown to correlate well with simultaneously acquired airflow data in 10 volunteers(r=0.93±0.04). The TPM navigated images had a significantly higher subjective image quality and edge sharpness (P<0.0001) than averaged spiral TPM. No significant differences in myocardial velocities were seen between conventional Cartesian TPM with navigator respiratory-gating and the proposed self-navigated TPM technique, in 10 volunteers. Significant differences in the velocities were seen between the volunteers and patients in the left ventricle at systole and end diastole and in the right ventricle at end diastole. Conclusion The feasibility of measuring myocardial motion using a golden-angle spiral TPM sequence was demonstrated, with an image-based respiratory navigator calculated from the TPM data itself

    Validity of the Polar V800 heart rate monitor to measure RR intervals at rest

    Get PDF
    Purpose To assess the validity of RR intervals and short-term heart rate variability (HRV) data obtained from the Polar V800 heart rate monitor, in comparison to an electrocardiograph (ECG). Method Twenty participants completed an active orthostatic test using the V800 and ECG. An improved method for the identification and correction of RR intervals was employed prior to HRV analysis. Agreement of the data was assessed using intra-class correlation coefficients (ICC), Bland–Altman limits of agreement (LoA), and effect size (ES). Results A small number of errors were detected between ECG and Polar RR signal, with a combined error rate of 0.086 %. The RR intervals from ECG to V800 were significantly different, but with small ES for both supine corrected and standing corrected data (ES 0.999 for both supine and standing corrected intervals. When analysed with the same HRV software no significant differences were observed in any HRV parameters, for either supine or standing; the data displayed small bias and tight LoA, strong ICC (>0.99) and small ES (≤0.029). Conclusions The V800 improves over previous Polar models, with narrower LoA, stronger ICC and smaller ES for both the RR intervals and HRV parameters. The findings support the validity of the Polar V800 and its ability to produce RR interval recordings consistent with an ECG. In addition, HRV parameters derived from these recordings are also highly comparable

    Psychiatric Context of Acute/Early HIV Infection. The NIMH Multisite Acute HIV Infection Study: IV

    Get PDF
    Acute/early HIV infection is a period of high risk for HIV transmission. Better understanding of behavioral aspects during this period could improve interventions to limit further transmission. Thirty-four participants with acute/early HIV infection from six US cities were assessed with the Mini International Diagnostic Interview, Beck Depression Inventory II, State-Trait Anxiety Inventory, Brief COPE, and an in-depth interview. Most had a pre-HIV history of alcohol or substance use disorder (85%); a majority (53%) had a history of major depressive or bipolar disorder. However, post-diagnosis coping was predominantly adaptive, with only mild to moderate elevations of anxious or depressive mood. Respondents described challenges managing HIV in tandem with pre-existing substance abuse problems, depression, and anxiety. Integration into medical and community services was associated with adaptive coping. The psychiatric context of acute/early HIV infection may be a precursor to infection, but not necessarily a barrier to intervention to reduce forward transmission of HIV among persons newly infected

    Impaired perception of facial motion in autism spectrum disorder

    Get PDF
    Copyright: © 2014 O’Brien et al. This is an open-access article distributed under the terms of the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are credited.This article has been made available through the Brunel Open Access Publishing Fund.Facial motion is a special type of biological motion that transmits cues for socio-emotional communication and enables the discrimination of properties such as gender and identity. We used animated average faces to examine the ability of adults with autism spectrum disorders (ASD) to perceive facial motion. Participants completed increasingly difficult tasks involving the discrimination of (1) sequences of facial motion, (2) the identity of individuals based on their facial motion and (3) the gender of individuals. Stimuli were presented in both upright and upside-down orientations to test for the difference in inversion effects often found when comparing ASD with controls in face perception. The ASD group’s performance was impaired relative to the control group in all three tasks and unlike the control group, the individuals with ASD failed to show an inversion effect. These results point to a deficit in facial biological motion processing in people with autism, which we suggest is linked to deficits in lower level motion processing we have previously reported

    Effects of growth rate, size, and light availability on tree survival across life stages: a demographic analysis accounting for missing values and small sample sizes.

    Get PDF
    The data set supporting the results of this article is available in the Dryad repository, http://dx.doi.org/10.5061/dryad.6f4qs. Moustakas, A. and Evans, M. R. (2015) Effects of growth rate, size, and light availability on tree survival across life stages: a demographic analysis accounting for missing values.Plant survival is a key factor in forest dynamics and survival probabilities often vary across life stages. Studies specifically aimed at assessing tree survival are unusual and so data initially designed for other purposes often need to be used; such data are more likely to contain errors than data collected for this specific purpose

    Test-retest reliability of knee kinesthesia in healthy adults

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>Sensory information from mechanoreceptors in the skin, muscles, tendons, and joint structures plays an important role in joint stability. A joint injury can lead to disruption of the sensory system, which can be measured by proprioceptive acuity. When evaluating proprioception, assessment tools need to be reliable. The aim of this study was to assess the test-retest reliability of a device designed to measure knee proprioception.</p> <p>Methods</p> <p>Twenty-four uninjured individuals (14 women and 10 men) were examined with regard to test-retest reliability of knee kinesthesia, measured by the threshold to detection of passive motion (TDPM). Measurements were performed towards extension and flexion from the two starting positions, 20 degrees and 40 degrees knee joint flexion, giving four variables. The mean difference between test and retest together with the 95% confidence interval (test 2 minus test 1), the intraclass correlation coefficient (ICC<sub>2,1</sub>), and Bland and Altman graphs with limits of agreement, were used as statistical methods for assessing test-retest reliability.</p> <p>Results</p> <p>The intraclass correlation coefficients ranged from 0.59 to 0.70 in all variables except one. No difference was found between test and retest in three of the four TDPM variables. TDPM would need to decrease between 10% and 38%, and increase between 17% and 24% in groups of uninjured subjects to be 95% confident of detecting a real change. The limits of agreement were rather wide in all variables. The variables associated with the 20-degree starting position tended to have higher intraclass correlation coefficients and narrower limits of agreement than those associated with 40 degrees.</p> <p>Conclusion</p> <p>Three TDPM variables were considered reliable for observing change in groups of subjects without pathology. However, the limits of agreement revealed that small changes in an individual's performance cannot be detected. The higher intraclass correlation coefficients and the narrower limits of agreement in the variables associated with the starting position of 20 degrees knee joint flexion, indicate that these variables are more reliable than those associated with 40 degrees. We, therefore, recommend that the TDPM be measured with a 20-degree starting position.</p

    Economic Impact of Dengue Illness and the Cost-Effectiveness of Future Vaccination Programs in Singapore

    Get PDF
    Dengue illness is a tropical disease transmitted by mosquitoes that threatens more than one third of the worldwide population. Dengue has important economic consequences because of the burden to hospitals, work absenteeism and risk of death of symptomatic cases. Governments attempt to reduce the disease burden using costly mosquito control strategies such as habitat reduction and spraying insecticide. Despite such efforts, the number of cases remains high. Dengue vaccines are expected to be available in the near future and there is an urgent need to evaluate their cost-effectiveness, i.e. whether their cost will be justified by the reduction in disease burden they bring. For such an evaluation, we estimated the economic impacts of dengue in Singapore and the expected vaccine costs for different prices. In this way we estimated price thresholds for which vaccination is not cost-effective. This research provides useful estimates that will contribute to informed decisions regarding the adoption of dengue vaccination programs

    Development of the conceptual framework for the Eye-Drop Satisfaction Questionnaire (EDSQ©) in glaucoma using a qualitative study

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>Compliance is a major issue in glaucoma care. It is usually poor in glaucomatous patients, and may ultimately result in an acceleration of the disease progression and a risk of blindness. Reasons for this poor compliance are complex and multifactorial, amongst which patient satisfaction can be counted. The objective of this study was to develop a questionnaire to assess patient satisfaction and compliance with eye-drop treatment.</p> <p>Methods</p> <p>A qualitative study was carried out to develop the questionnaire. An interview guide was developed based on a literature review. Structured interviews of fifteen French and English patients with primary open-angle glaucoma or intraocular hypertension were conducted by trained interviewers of the native language of the interviewees. General concepts and subconcepts were identified from the transcripts. The questionnaire was developed using the patient verbatim, and submitted to six patients (French and English) for cognitive debriefing. Following patients' comments, items were modified and restructured, and a pilot questionnaire was designed.</p> <p>Results</p> <p>Analysis of data from the interviews with patients and clinicians resulted in the elicitation of concepts related to patient satisfaction and compliance with glaucomatous treatment. These were further refined and used to generate a test questionnaire, which consisted of 46 items grouped into 6 domains: patient characteristics, treatment characteristics, patient-clinician relationship, patient experience with the disease and the treatment, interaction between the patient and the treatment, and patient knowledge of the disease and the treatment.</p> <p>Conclusion</p> <p>The Eye-Drop Satisfaction Questionnaire (EDSQ) conceptual framework and items were developed simultaneously in French and in English. This questionnaire could be used to evaluate patient satisfaction and compliance with eye-drop treatment and would facilitate the identification of patients at risk of being non-compliant prior to clinical trials or innovative device tests. A psychometric study is under way to validate the questionnaire.</p
    corecore