21 research outputs found

    Phagocytosis and macrophage polarisation on bacterially contaminated dental implant materials and effects on tissue integration

    Get PDF
    Bacterial contamination is hard to avoid during dental implant surgery. Macrophages and their polarisation play a decisive role in bacterial colonisation and tissue integration on bacterially contaminated dental implants. The present study investigated the role of macrophages in stimulating tissue coverage overgrowth of contaminating oral bacteria on polished titanium (Ti-P) and acid-etched zirconium dioxide (ZrO2-MA) dental implant materials. Different co-culture models were employed to determine phagocytosis rates of Streptococcus mitis or Staphylococcus aureus contaminating a dental implant surface and the influence of contaminating bacteria and osteoblasts (U2OS) on macrophage polarisation. S. aureus was phagocytized in higher numbers than S. mitis in bi-cultures on smooth Ti-P surfaces. Contaminating S. mitis stimulated near full polarisation of macrophages from a non-Ym1-expressing- to a Ym1-expressing-phenotype on smooth Ti-P, but on ZrO2-MA both phenotypes occurred. In tri-cultures with U2OS-cells on smooth Ti-P, a larger percentage of macrophages remained in their non-Ym1-expressing, "fighting" M1-like phenotype to clear Ti-P surfaces from contaminating bacteria. On ZrO2-MA surfaces, more macrophages tended towards their "fixand-repair" M2-like phenotype than on Ti-P surfaces. Surface coverage of smooth, bacterially contaminated Ti-P surfaces by U2OS-cells was more effectively stimulated by fighting, M1-like macrophages than on ZrO2-MA surfaces. Comprehensive guidelines are provided for the development of infection-resistant, dental implant materials, including bacteria, tissue and immune cells. These guidelines point to more promising results for clinical application of Ti-P as compared with ZrO2-MA

    Polarization of Macrophages, Cellular Adhesion, and Spreading on Bacterially Contaminated Gold Nanoparticle-Coatings in Vitro

    Get PDF
    Biomaterial-associated infections often arise from contaminating bacteria adhering to an implant surface that are introduced during surgical implantation and not effectively eradicated by antibiotic treatment. Whether or not infection develops from contaminating bacteria depends on an interplay between bacteria contaminating the biomaterial surface and tissue cells trying to integrate the surface with the aid of immune cells. The biomaterial surface plays a crucial role in defining the outcome of this race for the surface. Tissue integration is considered the best protection of a biomaterial implant against infectious bacteria. This paper aims to determine whether and how macrophages aid osteoblasts and human mesenchymal stem cells to adhere and spread over gold nanoparticle (GNP)-coatings with different hydrophilicity and roughness in the absence or presence of contaminating, adhering bacteria. All GNP-coatings had identical chemical surface composition, and water contact angles decreased with increasing roughness. Upon increasing the roughness of the GNP-coatings, the presence of contaminating Staphylococcus epidermidis in biculture with cells gradually decreased surface coverage by adhering and spreading cells, as in the absence of staphylococci. More virulent Staphylococcus aureus fully impeded cellular adhesion and spreading on smooth gold- or GNP-coatings, while Escherichia coli allowed minor cellular interaction. Murine macrophages in monoculture tended toward their pro-inflammatory "fighting" M1-phenotype on all coatings to combat the biomaterial, but in bicultures with contaminating, adhering bacteria, macrophages demonstrated Ym1 expression, indicative of polarization toward their anti-inflammatory "fix-and-repair" M2-phenotype. Damage repair of cells by macrophages improved cellular interactions on intermediately hydrophilic/rough (water contact angle 30 deg/surface roughness 118 nm) GNP-coatings in the presence of contaminating, adhering Gram-positive staphylococci but provided little aid in the presence of Gram-negative E. coli. Thus, the merits on GNP-coatings to influence the race for the surface and prevent biomaterial-associated infection critically depend on their hydrophilicity/roughness and the bacterial strain involved in contaminating the biomaterial surface

    Surface thermodynamic homeostasis of salivary conditioning films through polar–apolar layering

    Get PDF
    Salivary conditioning films (SCFs) form on all surfaces exposed to the oral cavity and control diverse oral surface phenomena. Oral chemotherapeutics and dietary components present perturbations to SCFs. Here we determine the surface energetics of SCFs through contact angle measurements with various liquids on SCFs following perturbations with a variety of chemotherapeutics as well as after renewed SCF formation. Sixteen-hour SCFs on polished enamel surfaces were treated with a variety of chemotherapeutics, including toothpastes and mouthrinses. After treatment with chemotherapeutics, a SCF was applied again for 3 h. Contact angles with four different liquids on untreated and treated SCF-coated enamel surfaces were measured and surface free energies were calculated. Perturbations either caused the SCF to become more polar or more apolar, but in all cases, renewed SCF formation compensated these changes. Thus, a polar SCF attracts different salivary proteins or adsorbs proteins in a different conformation to create a more apolar SCF surface after renewed SCF formation and vice versa for apolar SCFs. This polar–apolar layering in SCF formation presents a powerful mechanism in the oral cavity to maintain surface thermodynamic homeostasis—defining oral surface properties within a narrow, biological range and influencing chemotherapeutic strategies. Surface chemical changes brought about by dietary or chemotherapeutic perturbations to SCFs make it more polar or apolar, but new SCFs are rapidly formed compensating for changes in surface energetics

    Efficacy and mechanisms of non-antibacterial, chemical plaque control by dentifrices - An in vitro study

    No full text
    Objectives: The provision of antiplaque benefits to dentifrices assists patients in improving hygiene and reducing susceptibility to gingivitis and caries. Chemical plaque control involves different mechanisms and is mostly associated with antibacterial effects, but also includes effects on pellicle surface chemistry to improve cleansing or discourage renewed plaque formation. it is the aim of this paper to analyze in vitro detachment of co-aggregating oral actinomyces and streptococci from pellicle surfaces by dentifrice supernates and to study subsequent de novo streptococcal deposition. Methods: Detachment by dentifrices of a co-adhering bacterial pair was studied in the parallel plate flow chamber on a 16 h pellicle coated surface. After detachment by perfusing the chamber with a dentifrice, re-deposition was initiated by flowing with a fresh streptococcal suspension. The dentifrices included both a regular, SLS-fluoride based formulation as well a pyrophosphate, anticalculus and antimicrobial formulations. Results: All dentifrice supernates containing SLS were effective in detaching co-adhering bacteria from pellicles surfaces, except in combination with SnF(2). When hexametaphosphate was added immediate detachment was relatively low, but continued even during redeposition. The re-deposition of streptococci after detachment by other, NaF containing dentifrices involved relatively few large aggregates, presumably because fluoride was able to block bi-dentate calcium binding sites on the bacterial cell surfaces, mediating co-adhesion. When pyrophosphate was present in addition to NaF, re-deposition involved significantly more large aggregates, likely because pyrophosphate served as a bi-dentate bridge between calcium bound on the bacterial cell surfaces. Conclusion: Commercially available dentifrice formulations differ in their ability to stimulate bacterial detachment from pellicles and dependent on their composition yield the formation of large co-adhering aggregates of actinomyces and streptococci in de novo deposition. (c) 2006 Elsevier Ltd. All rights reserved

    A method to study sustained antimicrobial activity of rinse and dentifrice components on biofilm viability in vivo

    No full text
    Aim: To develop an improved method for quantitative assessment of antimicrobial efficacy and substantivity of mouth rinses and dentifrices on in vivo treated plaque. Materials and Methods: Nine- and 72-h-old plaques were formed in volunteers carrying out standardized hygiene using NaF-containing dentifrice. Plaques were collected before (baseline) in vivo treatment with dentifrices or chlorhexidine mouth rinse, immediately post-treatment and after 1 or 6 h, dispersed in demineralized water and stained with live/dead stain after which bacteria were enumerated. Dispersed baseline plaques were treated with dentifrices or chlorhexidine to determine antimicrobial efficacy against planktonic bacteria. Results: Baseline plaques revealed 56-41% viable organisms in 9- and 72-h-old plaques, respectively. Treatment of planktonic (dispersed baseline plaque) bacteria resulted in 1-4% viable organisms. Chlorhexidine mouth rinse and dentifrices produced strong immediate antimicrobial effects, but after 1 or 6 h, the proportion of viable organisms in 9-h-old plaques rebounded significantly with only chlorhexidine mouth rinse retaining significant efficacy. Seventy-two-hour-old plaques were less susceptible to antimicrobials, although dentifrices appeared more effective after 6 h than initially, whereas efficacy of chlorhexidine rinse continued to drop with time post-treatment. Conclusions: The proposed method holds promise for assessment of both immediate and retained antimicrobial actions of oral treatments against dental plaque in vivo

    Surfactive and antibacterial activity of cetylpyridinium chloride formulations in vitro and in vivo

    No full text
    Aim: To compare effects of three cetylpyridinium chloride (CPC) formulations with and without alcohol and Tween80 on physico-chemical properties of salivary pellicles, bacterial detachment in vitro and bacterial killing in vivo. Material and Methods: Adsorption of CPC to salivary pellicles in vitro was studied using X-ray photoelectron spectroscopy and water contact angle measurements. Adhesion and detachment of a co-adhering bacterial pair was determined in vitro using a flow chamber. Killing was evaluated after live/dead staining after acute single use in vivo on 24- and 72-h-old plaques after 2-week continuous use. Results: The most pronounced effects on pellicle surface chemistry and hydrophobicity were observed after treatment with the alcohol-free formulation, while the pellicle thickness was not affected by any of the formulations. All CPC formulations detached up to 33% of the co-adhering pair from pellicle surfaces. Bacterial aggregate sizes during de novo deposition were enhanced after treatment with the alcohol-free formulation. Immediate and sustained killing in 24 and 72 h plaques after in vivo, acute single use as well as after 2-week continuous use were highest for the alcohol-free formulation. Conclusions: CPC bioavailability in a formulation without alcohol and Tween80 could be demonstrated through measures of pellicle surface properties and bacterial interactions in vitro as well as bacteriocidal actions on oral biofilms in vivo

    Influence of adhesion to activated carbon particles on the viability of waterborne pathogenic bacteria under flow

    No full text
    In rural areas around the world, people often rely on water filtration plants using activated carbon particles for safe water supply. Depending on the carbon surface, adhering microorganisms die or grow to form a biofilm. Assays to assess the efficacy of activated carbons in bacterial removal do not allow direct observation of bacterial adhesion and the determination of viability. Here we propose to use a parallel plate flow chamber with carbon particles attached to the bottom plate to study bacterial adhesion to individual carbon particles and determine the viability of adhering bacteria. Observation and enumeration is done after live/dead staining in a confocal laser scanning microscope. Escherichiae coli adhered in higher numbers than Raoultella terrigena, except to a coconut-based carbon, which showed low bacterial adhesion compared to other wood-based carbon types. After adhesion, 83-96% of the bacteria adhering to an acidic carbon were dead, while on a basic carbon 54-56% were dead. A positively charged, basic carbon yielded 76-78% bacteria dead, while on a negatively charged coconut-based carbon only 32-37% were killed upon adhesion. The possibility to determine both adhesion as well as the viability of adhering bacteria upon adhesion to carbon particles is most relevant, because if bacteria adhere but remain viable, this still puts the water treatment system at risk, as live bacteria can grow and form a biofilm that can then be shedded to cause contamination

    Synergy of brushing mode and antibacterial use on in vivo biofilm formation

    No full text
    Objectives: Orthodontic, multi-strand retention-wires are used as a generalized model for oral retention sites to investigate whether biofilm left-behind after powered toothbrushing in-vivo enabled better penetration of antibacterials as compared with manual brushing. Methods: 2-cm multi-strand, stainless-steel retention-wires were placed in brackets bonded bilaterally in the upper arches of 10-volunteers. Volunteers used NaF-sodium-lauryl-sulphate-containing toothpaste and antibacterial, triclosan-containing toothpaste supplemented or not with an essential-oils containing mouthrinse. Opposite sides of the dentition including the retention-wires, were brushed manually or with a powered toothbrush. Health-care-regimens were maintained for 1-week, after which wires were removed and oral biofilm was collected. Results: When powered toothbrushing was applied, slightly less bacteria were collected than after manual brushing, regardless whether an antibacterial-regimen was used or not. Powered-toothbrushing combined with antibacterial-regimens yielded lower biofilm viability than manual brushing, indicating better antibacterial penetration into biofilm left-behind after powered brushing. Major shifts in biofilm composition, with a decrease in prevalence of both cariogenic species and periodontopathogens, were induced after powered brushing using an antibacterial-regimen. Conclusion: Oral biofilm left-behind after powered brushing in-vivo enabled better penetration of antibacterials than after manual brushing. Clinical significance: Mechanical removal of oral biofilm is important for prevention of dental pathologies, but biofilm is always left-behind, such as in fissures, buccal pits, interproximal areas and gingival margins and around orthodontic appliances. Use of antibacterial toothpastes or mouthrinses can contribute to removal or killing of biofilm bacteria, but biofilm structure hampers antibacterial penetration. A synergy between brushing mode and antibacterial-regimen applied exists with clinically demonstrable effects. (C) 2015 Elsevier Ltd. All rights reserved

    Biofilm composition and composite degradation during intra-oral wear

    Get PDF
    Objectives. The oral environment limits the longevity of composite-restorations due to degradation caused by chewing, salivary and biofilm-produced enzymes and acids. This study investigates degradation of two resin-composites in relation with biofilm composition in vitro and in vivo. Methods. Surface-chemical-composition of two Bis-GMA/TEGDMA composites was compared using X-ray-Photoelectron-Spectroscopy from which the number ester-linkages was derived. Composite-degradation was assessed through water contact angles, yielding surface-exposure of filler-particles. Degradation in vitro was achieved by composite immersion in a lipase solution. In order to evaluate in vivo degradation, composite samples were worn in palatal devices by 15 volunteers for 30-days periods in absence and presence of manually-brushing with water. PCR-DGGE analysis was applied to determine biofilm composition on the samples, while in addition to water contact angles, degradation of worn composites was assessed through surface-roughness and micro-hardness measurements. Results. In vitro degradation by lipase exposure was highest for the high ester-linkage composite and virtually absent for the low ester-linkage composite. Filler-particle surface-exposure, surface-roughness and micro-hardness of both resin-composites increased during intra-oral wear, but filler-particle surface-exposure was affected most. However, based on increased filler-particle surface-exposure, the high ester-linkage composite degraded most in volunteers harvesting composite biofilms comprising Streptococcus mutans, a known esterase and lactic acid producer. This occurred especially in absence of brushing. Significance. Degradation during intra-oral wear of a low ester-linkage composite was smaller than of a high ester-linkage composite, amongst possible other differences between both composites. S. mutans herewith is not only a cariogenic, but also a composite-degradative member of the oral microbiome. (C) 2019 Published by Elsevier Inc. on behalf of The Academy of Dental Materials
    corecore