277 research outputs found

    The new INRIM rotating encoder angle comparator (REAC)

    Get PDF
    A novel angle comparator has been built and tested at INRIM. The device is based on a double air bearing structure embedding a continuously rotating encoder, which is read by two heads: one fixed to the base of the comparator and a second fixed to the upper moving part of the comparator. The phase measurement between the two heads’ signals is proportional to the relative angle suspended between them (and, therefore, the angle between the base and the upper, movable part of the comparator). The advantage of this solution is to reduce the encoder graduation errors and to cancel the cyclic errors due to the interpolation of the encoder lines. By using only two pairs of reading heads, we have achieved an intrinsic accuracy of ±0.04″ (rectangular distribution) that can be reduced through self-calibration. The residual cyclic errors have shown to be less than 0.01″ peak-to-peak. The random fluctuations are less than 0.01″ rms on a 100 s time interval. A further advantage of the rotating encoder is the intrinsic knowledge of the absolute position without the need of a zeroing procedure. Construction details of the rotating encoder angle comparator (REAC), characterization tests, and examples of practical use are given

    Sensor for the Characterization of 2D Angular Actuators with Picoradian Resolution and Nanoradian Accuracy with Microradian Range

    Get PDF
    High precision angular actuators are used for high demanding applications such as laser steering for photolithography. Piezo technology allows developing actuators with a resolution as low as a few nanoradians, with bandwidths as high as several kilohertz. In most demanding applications, the actual performance of these instruments needs to be characterized. The best angular measurement instruments available today do not sucient resolution and/or bandwidth to satisfy these needs. At the Istituto Nazionale di Ricerca Metrologica, INRIM a device was designed and built aiming at characterizing precision 2D angular actuators with a resolution surpassing the best devices on the market. The device is based on a multi reflection scheme that allows multiplying the deflection angle by a factor of 70. The ultimate resolution of the device is 2 prad/radq(Hz) over a measurement range of 36 urad with a measurement band >10 kHz. The present work describes the working principle, the practical realization, and a case study on a top-level commercial angular actuator (Nano-MTA2 produced by Mad City Labs)

    Traceability of gravity acceleration measurement in calibration laboratories

    Get PDF
    Primary measurements of force, torque and pressureare directly influenced by local gravityacceleration,g. At present, gmeasurementin calibration laboratoriesisevaluated through absolute or relative measurementsor through theoretical/empiricalrelations. Except forsome absolute measurements, other methods are not traceable. As consequence, measurementsofthesequantities could behighly impacted by this lackin terms of accuracy and uncertainty.The Consultative Committee for Mass and related quantities (CCM) of CIPM and International Association of Geodesy (IAG) arecurrently working ona resolutionstrategy to ensure traceability to the SI for gravity measurementsthrough the establishment of a global absolute gravity reference system. Thisnetwork could becomea useful tool to transferthe gmeasurement to calibration laboratories at international level. However, as well any other measurements, thispossible solution should be established under the Quality Management system of accredited laboratories

    Characterization of Angle Accuracy and Precision of 3-Degree-of-Freedom Absolute Encoder Based on NanoGPS OxyO Technology

    Get PDF
    An absolute encoder based on vision system nanoGPS OxyO was developed by HORIBA France. This encoder provides three types of position information, namely, two inplane co-ordinates and inplane angular orientation. This paper focuses on the characterization of its angular performance. To this aim, the nanoGPS OxyO system was compared with the national angle standard of the National Metrology Institute of Italy (INRIM) that had evaluated accuracy of about 0.1 urad. The effect of image size and illumination conditions on angular measurements was studied. Precision better than 10 urad and accuracy better than 63 urad over 2Ï€ rotation were demonstrated. Moreover, the application of nanoGPS OxyO to the characterization of rotation bearing is presented. Small deviations from pure rotational behavior were evidenced that would have not been possible using laser interferometers. As a consequence of its accuracy and versatility, the nanoGPS OxyO encoder is expected to be useful for laboratory experiments and quality-control tasks

    Realisation of an optical pressure standard by a multi-reflection interferometric technique

    Get PDF
    A novel realization of an optical pressure standard, alternative to Fabry-Perot cavity-based techniques, is presented. It is based on the measurement of the refractive index of a gas through an unbalanced homodyne interferometer, designed to have one of its two arms formed by a multi reflection double mirror assembly to establish an unbalance length larger than 6 m in a compact setup. The paper illustrates the most important steps concerning its realization: the estimate of the pressure-induced deformation of the interferometer, the temperature control at millikelvin level and the measurement in vacuum of the unbalance of the interferometer. The evaluation of the uncertainty of the realized optical pressure standard currently demonstrated to fulfill the main goal of having the ability to measure pressure with a relative uncertainty of 10 ppm at 100 kPa

    BESII Detector Simulation

    Full text link
    A Monte Carlo program based on Geant3 has been developed for BESII detector simulation. The organization of the program is outlined, and the digitization procedure for simulating the response of various sub-detectors is described. Comparisons with data show that the performance of the program is generally satisfactory.Comment: 17 pages, 14 figures, uses elsart.cls, to be submitted to NIM
    • …
    corecore