244 research outputs found
Model of unidirectional block formation leading to reentrant ventricular tachycardia in the infarct border zone of postinfarction canine hearts
AbstractBackgroundWhen the infarct border zone is stimulated prematurely, a unidirectional block line (UBL) can form and lead to double-loop (figure-of-eight) reentrant ventricular tachycardia (VT) with a central isthmus. The isthmus is composed of an entrance, center, and exit. It was hypothesized that for certain stimulus site locations and coupling intervals, the UBL would coincide with the isthmus entrance boundary, where infarct border zone thickness changes from thin-to-thick in the travel direction of the premature stimulus wavefront.MethodA quantitative model was developed to describe how thin-to-thick changes in the border zone result in critically convex wavefront curvature leading to conduction block, which is dependent upon coupling interval. The model was tested in 12 retrospectively analyzed postinfarction canine experiments. Electrical activation was mapped for premature stimulation and for the first reentrant VT cycle. The relationship of functional conduction block forming during premature stimulation to functional block during reentrant VT was quantified.ResultsFor an appropriately placed stimulus, in accord with model predictions: 1. The UBL and reentrant VT isthmus lateral boundaries overlapped (error: 4.8±5.7mm). 2. The UBL leading edge coincided with the distal isthmus where the center-entrance boundary would be expected to occur. 3. The mean coupling interval was 164.6±11.0ms during premature stimulation and 190.7±20.4ms during the first reentrant VT cycle, in accord with model calculations, which resulted in critically convex wavefront curvature and functional conduction block, respectively, at the location of the isthmus entrance boundary and at the lateral isthmus edges.DiscussionReentrant VT onset following premature stimulation can be explained by the presence of critically convex wavefront curvature and unidirectional block at the isthmus entrance boundary when the premature stimulation interval is sufficiently short. The double-loop reentrant circuit pattern is a consequence of wavefront bifurcation around this UBL followed by coalescence, and then impulse propagation through the isthmus. The wavefront is blocked from propagating laterally away from the isthmus by sharp increases in border zone thickness, which results in critically convex wavefront curvature at VT cycle lengths
The mapping class group and the Meyer function for plane curves
For each d>=2, the mapping class group for plane curves of degree d will be
defined and it is proved that there exists uniquely the Meyer function on this
group. In the case of d=4, using our Meyer function, we can define the local
signature for 4-dimensional fiber spaces whose general fibers are
non-hyperelliptic compact Riemann surfaces of genus 3. Some computations of our
local signature will be given.Comment: 24 pages, typo adde
Quantum cryptography using balanced homodyne detection
We report an experimental quantum key distribution that utilizes balanced
homodyne detection, instead of photon counting, to detect weak pulses of
coherent light. Although our scheme inherently has a finite error rate, it
allows high-efficiency detection and quantum state measurement of the
transmitted light using only conventional devices at room temperature. When the
average photon number was 0.1, an error rate of 0.08 and "effective" quantum
efficiency of 0.76 were obtained.Comment: Errors in the sentence citing ref.[20] are correcte
Experimental and numerical validation of tape-based metasurfaces in guiding high-frequency surface waves for efficient power transfer
We present an effective method for transmitting electromagnetic waves as surface waves with a tape-based metasurface design. This design incorporates silver square patches periodically patterned on an adhesive tape substrate. Specifically, our study proposes a strategy to enhance the efficiency of power transfer in high-frequency bands by guiding signals as surface waves rather than free-space waves. Both the numerical and experimental results validate the markedly enhanced efficiency in power transfer of high-frequency signals compared to that achieved with conventional methods, such as wireless power transfer and microstrips. Importantly, our metasurface design can be readily manufactured and tailored for various environments. Thus, our study contributes to designing power-efficient next-generation communication systems such as 6G and 7G, which leverage high-frequency signals in the millimeter-wave and terahertz bands
Identification of PDL-1 as a novel biomarker of sensitizer exposure in dendritic-like cells
The development of novel in vitro methods to assess risks of allergic sensitization are essential in reducing animal testing whilst maintaining consumer safety. The main research objectives of this study were to identify novel biomarkers to assess the sensitization predictability of chemicals. Phenotypic and cytokine responses of moDCs and MUTZ-3 cells were investigated following application of contact sensitizers; dinitrochlorobenzene (DNCB), cinnamaldehyde (Cin), eugenol (E), isoeugenol (IE), P-phenylenediamine (PPD) and non-sensitizers; salicyclic acid (SA) and sodium lauryl sulphate (SLS). CD86 was up-regulated on MUTZ-3 cells in response to DNCB, Cin and PPD, however, moDCs only modulated CD86 in response to DNCB and E. PDL-1 (Programmed death receptor ligand-1) proved a promising sensitization biomarker in MUTZ-3 cells where up-regulation occurred in response to DNCB, Cin, IE and PPD. Additionally, moDC-expressed PDL-1 was modulated in response to Cin, IE and E thus demonstrating improved sensitizer predictability when compared with CD86. MCP-1 and RANTES were identified as biomarkers of DNCB exposure but MCP-1 did not show any change in expression above controls for the other sensitizers investigated. However, RANTES was increased in MUTZ-3 cells by both DNCB and Cin. Our findings highlight novel biomarkers which, in MUTZ-3 cells, could be taken forward within a multiple biomarker in vitro assay ensuring strong and reliable predictability. © 2010 Elsevier Ltd
Subendocardial contractile impairment in chronic ischemic myocardium: assessment by strain analysis of 3T tagged CMR
<p>Abstract</p> <p>Background</p> <p>The purpose of this study was to quantify myocardial strain on the subendocardial and epicardial layers of the left ventricle (LV) using tagged cardiovascular magnetic resonance (CMR) and to investigate the transmural degree of contractile impairment in the chronic ischemic myocardium.</p> <p>Methods</p> <p>3T tagged CMR was performed at rest in 12 patients with severe coronary artery disease who had been scheduled for coronary artery bypass grafting. Circumferential strain (C-strain) at end-systole on subendocardial and epicardial layers was measured using the short-axis tagged images of the LV and available software (Intag; Osirix). The myocardial segment was divided into stenotic and non-stenotic segments by invasive coronary angiography, and ischemic and non-ischemic segments by stress myocardial perfusion scintigraphy. The difference in C-strain between the two groups was analyzed using the Mann-Whitney U-test. The diagnostic capability of C-strain was analyzed using receiver operating characteristics analysis.</p> <p>Results</p> <p>The absolute subendocardial C-strain was significantly lower for stenotic (-7.5 ± 12.6%) than non-stenotic segment (-18.8 ± 10.2%, p < 0.0001). There was no difference in epicardial C-strain between the two groups. Use of cutoff thresholds for subendocardial C-strain differentiated stenotic segments from non-stenotic segments with a sensitivity of 77%, a specificity of 70%, and areas under the curve (AUC) of 0.76. The absolute subendocardial C-strain was significantly lower for ischemic (-6.7 ± 13.1%) than non-ischemic segments (-21.6 ± 7.0%, p < 0.0001). The absolute epicardial C-strain was also significantly lower for ischemic (-5.1 ± 7.8%) than non-ischemic segments (-9.6 ± 9.1%, p < 0.05). Use of cutoff thresholds for subendocardial C-strain differentiated ischemic segments from non-ischemic segments with sensitivities of 86%, specificities of 84%, and AUC of 0.86.</p> <p>Conclusions</p> <p>Analysis of tagged CMR can non-invasively demonstrate predominant impairment of subendocardial strain in the chronic ischemic myocardium at rest.</p
First experimental determination of the radiative-decay probability of the 31− state in ¹²C for estimating the triple alpha reaction rate in high temperature environments
The triple alpha reaction is one of the most important reactions in the nuclear astrophysics. However, its reaction rate in high temperature environments at T₉>2 was still uncertain. One of the major origins of the uncertainty was that the radiative-decay probability of the 3⁻₁ state in ¹²C was unknown. In the present work, we have determined the radiative-decay probability of the 3⁻₁ state to be 1.3[+1.2][-1.1] × 10⁻⁶ by measuring the ¹H(¹²C, ¹²Cp) reaction for the first time, and derived the triple alpha reaction rate in high temperature environments from the measured radiative-decay probability. The present result suggests that the 3⁻₁ state noticeably enhances the triple alpha reaction rate although the contribution from the 3⁻₁ state had been assumed to be small
- …