4 research outputs found

    Magnetic resonance-guided focused ultrasound treatment of facet joint pain: summary of preclinical phase

    Get PDF
    STUDY DESIGN: A phantom experiment, two thermocouple experiments, three in vivo pig experiments, and a simulated treatment on a healthy human volunteer were conducted to test the feasibility, safety, and efficacy of magnetic resonance-guided focused ultrasound (MRgFUS) for treating facet joint pain. OBJECTIVE: The goal of the current study was to develop a novel method for accurate and safe noninvasive facet joint ablation using MRgFUS. SUMMARY OF BACKGROUND DATA: Facet joints are a common source of chronic back pain. Direct facet joint interventions include medial branch nerve ablation and intra-articular injections, which are widely used, but limited in the short and long term. MRgFUS is a breakthrough technology that enables accurate delivery of high-intensity focused ultrasound energy to create a localized temperature rise for tissue ablation, using MR guidance for treatment planning and real-time feedback. METHODS: We validated the feasibility, safety, and efficacy of MRgFUS for facet joint ablation using the ExAblate 2000® System (InSightec Ltd., Tirat Carmel, Israel) and confirmed the system's ability to ablate the edge of the facet joint and all terminal nerves innervating the joint. A phantom experiment, two thermocouple experiments, three in vivo pig experiments, and a simulated treatment on a healthy human volunteer were conducted. RESULTS: The experiments showed that targeting the facet joint with energies of 150–450 J provides controlled and accurate heating at the facet joint edge without penetration to the vertebral body, spinal canal, or root foramina. Treating with reduced diameter of the acoustic beam is recommended since a narrower beam improves access to the targeted areas. CONCLUSIONS: MRgFUS can safely and effectively target and ablate the facet joint. These results are highly significant, given that this is the first study to demonstrate the potential of MRgFUS to treat facet joint pain

    Divalent cation levels in serum and preovulatory follicular fluid of women undergoing in vitro fertilization embryo transfer, Gynecol

    No full text
    Abstract In this controlled clinical study, we determined the serum and follicular fluid concentrations of the biologically active fractions of magnesium (Mg) and calcium (Ca) in 39 women undergoing controlled ovarian stimulation (COH) for in vitro fertilization (IVF) embryo transfer (ET). Serum levels of ionized Ca (Ca 2+ ) and ionized Mg (Mg 2+ ) were measured during day 3 of the IVF cycle, on the day of ovum pickup and 12 days following ET. Follicular fluid levels were measured on the day of ovum pickup. Serum levels of Mg 2+ decreased and Ca 2+ levels increased during the IVF cycle. Mg levels were significantly higher in follicular fluid than in serum. Ca 2+ and Mg 2+ may play a role in the preovulatory follicle, a possibility that warrants further study

    Magnetic resonance-guided focused ultrasound surgery (MRgFUS). Four ablation treatments of a single canine hepatocellular adenoma

    Get PDF
    Background. Canine hepatocellular adenomas are benign, well-differentiated, primary hepatic tumors. Surgical resection is technically demanding and is considered a major procedure with relatively high morbidity rates. Magnetic resonance-guided focused ultrasound surgery (MRgFUS) uses focused ultrasonic energy to non-invasively create a heat-coagulated lesion deep within the body. This effect can be achieved in a controlled, accurate manner. The aim of this study was to evaluate the safety, accuracy and efficacy of non-invasive focal ablation of tissue volumes of a canine benign liver tumour by consecutive MRgFUS sonications. Materials and methods. Four MRgFUS procedures were performed in a 10-year-old, male, mixed large breed dog (45 kg) under general anaesthesia. The exact location and volume of the ablated areas were planned on the MR images. Real-time MR imaging and temperature mapping enabled the immediate evaluation of the effect of each sonication. Different areas were chosen within the tumour. These volumes of tumoral tissue were ablated by multiple sonications. To allow accurate targeting and quality imaging, sonications were performed during 20–30 s of apnoea. Between the sonications the dog was normally ventilated. The dog was operated 21 days after the fourth ablative procedure. The tumour was resected and histopathologically examined. Results. The MRgFUS created necrosis with contiguous areas of complete tissue destruction within the liver tumour, in full accordance with the planning. A focal thermal injury to the cartilage of the right lower ribs was noted after the fourth treatment. This lesion became infected and was treated surgically. Ten months after the last treatment the dog is well and healthy. Conclusions. Focused ultrasound ablation of liver tumoral tissue with MR guidance under general anaesthesia and controlled apnoea is a safe and accurate treatment modality. Its main advantage is that it is a completely non-invasive image-guided treatment. The ablation of significant volumes of a highly vascular liver tumoral tissue was achieved. Such tissue can be ablated in a very accurate manner, exactly according to the pretreatment planning on the MR images. The MR imaging characteristics, including real-time temperature mapping, enable real-time control of every step of the ablation process. Mechanical ventilation with intermittent apnoea periods overcomes the problem of the respiratory movements of the liver. Care must be taken to avoid the passage of the ultrasound beam through energy-absorbing calcified tissue
    corecore