79 research outputs found

    La microsonde basse énergie à base d'agrégats

    No full text
    AC

    La ligne emergente de COMPLIS

    No full text
    La ligne de transport d'ions produits par photo-ionisation resonante dans le dispositif experimental COMPLIS du CERN est decrite et analysee. La focalisation en temps et la resolution sont etudiees en fonction des potentiels appliques au point de production grace a un code de calcul iteratif specialement adapte

    Une selection d'applications des lasers

    No full text

    Les processus d'ionisation

    No full text

    Les sources de particules chargees

    No full text

    A High Power Lna Laser For Application To A New Polarized Electron Source

    No full text
    The recent development of high energy electron accelerators has generated a renewed interest in high current, high polarization electron sources. We have investigated several modifications to a method based on a pumped helium afterglow from which we expect improvements over the performances. These ones include the development of a high power, tunable LNA laser and the application of a new optical pumping scheme to the metastable helium atoms

    First attempt of the measurement of the beam polarization at an accelerator with the optical electron polarimeter POLO

    No full text
    The conventional methods for measuring the polarization of electron beams are either time consuming, invasive or accurate only to a few percent. We developed a method to measure electron beam polarization by observing the light emitted by argon atoms following their excitation by the impact of polarized electrons. The degree of circular polarization of the emitted fluorescence is directly related to the electron polarization. We tested the polarimeter on a test GaAs source available at the MAMI electron accelerator in Mainz, Germany. The polarimeter determines the polarization of a 50 keV electron beam decelerated to a few eV and interacting with an effusive argon gas jet. The resulting decay of the excited states produces the emission of a circularly polarized radiation line at 811.5 nm which is observed and analyzed

    Commissioning of the ALTO 50 MeV electron linac

    No full text
    online : http://accelconf.web.cern.ch/AccelConf/e06/PAPERS/MOPLS113.pdfThe ALTO 50 MeV electron linac is dedicated to the production of neutron-rich radioactive nuclei using the photo-fission process and the optimisation of the targetion source system for SPIRAL 2 and EURISOL projects. The accelerator consists of a 3 MeV injector (old test station of LAL, Laboratoire de l'Accélérateur Linéaire d'Orsay), LIL (Linac Injector of LEP) accelerating structure, RF power plant, beam line, control system and diagnostics. Specified and measured beam parameters will be compared to show the performances of the photofission process and eventually other applications

    COMPLIS experiments : COllaboration for spectroscopy Measurements using a Pulsed Laser Ion Source

    Get PDF
    Laser spectroscopy measurements have been carried out on very neutron-deficient isotopes of Au, Pt and Ir, produced as daughter elements from a Hg ISOLDE beam. For these transitional region nuclides, the hyperfine structure (HFS) and isotope shift (IS) were measured by Resonance Ionization Spectroscopy (RIS). Magnetic moments ÎŒ, spectroscopic quadrupole moments Qs and changes of the nuclear mean square charge radius ή〈rc 2〉along isotopic series have been extracted. For some results, a detailed comparison with theoretical predictions is presented. (Springer
    • 

    corecore