5 research outputs found

    Assessment of Sentinel-2 and Landsat-8 OLI for Small-Scale Inland Water Quality Modeling and Monitoring Based on Handheld Hyperspectral Ground Truthing

    Get PDF
    This study investigates the best available methods for remote monitoring inland small-scale waterbodies, using remote sensing data from both Landsat-8 and Sentinel-2 satellites, utilizing a handheld hyperspectral device for ground truthing. Monitoring was conducted to evaluate water quality indicators: chlorophyll-a (Chl-a), colored dissolved organic matter (CDOM), and turbidity. Ground truthing was performed to select the most suitable atmospheric correction technique (ACT). Several ACT have been tested: dark spectrum fitting (DSF), dark object subtraction (DOS), atmospheric and topographic correction (ATCOR), and exponential extrapolation (EXP). Classical sampling was conducted first; then, the resulting concentrations were compared to those obtained using remote sensing analysis by the above-mentioned ACT. This research revealed that DOS and DSF achieved the best performance (an advantage ranging between 29% and 47%). Further, we demonstrated the appropriateness of the use of Sentinel-2 red and vegetation red edge reciprocal bands (1/(B4 X B6)) for estimating Chl-a (R2 = 0.82, RMSE = 14.52mg/m3). As for Landsat-8, red to near-infrared ratio (B4/B5) produced the best performing model (R2 = 0.71, RMSE = 39.88 mg/m3), but it did not perform as well as Sentinel-2. Regarding turbidity, the best model (with (R2 =0.85, RMSE = 0.87 NTU) obtained by Sentinel-2 utilized a single band (B4), while the best model (with R2 = 0.64, RMSE = 0.90 NTU) using Landsat-8 was performed by applying two bands (B1/B3). Mapping the water quality parameters using the best performance biooptical model showed the significant effect of the adjacent land on the boundary pixels compared to pixels of deeper water

    Simultaneous Travel and Hoist Maneuver Input Shaping Control Using Frequency Modulation

    No full text
    This paper presents an input shaping control system for overhead crane operations involving simultaneous hoist and travel maneuvers. The control system utilizes model-based partial feedback linearization with frequency modulation. Traditional input shaping controllers target specific system frequencies. Therefore, they are incapable of accommodating the time dependant frequency associated with simultaneous hoist and travel crane maneuvers. Frequency modulation is used to tune the time-dependent system frequency to the design frequency of a primary input shaping controller. Partial feedback linearization is used to eliminate the time-dependent damping of the system. The primary input shaper frequency is based on lowest operating frequency of the system associated with the longest hoisting cable length operation. Simulations results, using primary zero-vibration (ZV) and zero-vibration-derivative (ZVD) input shapers, are presented. General arbitrary input travel and hoist commands are simulated. Results demonstrate the ability of the proposed control system to eliminate residual oscillations in all simulated cases

    Solar Irradiance Measurements Using Smart Devices: A Cost-Effective Technique for Estimation of Solar Irradiance for Sustainable Energy Systems

    No full text
    Solar irradiance measurement is a key component in estimating solar irradiation, which is necessary and essential to design sustainable energy systems such as photovoltaic (PV) systems. The measurement is typically done with sophisticated devices designed for this purpose. In this paper we propose a smartphone-aided setup to estimate the solar irradiance in a certain location. The setup is accessible, easy to use and cost-effective. The method we propose does not have the accuracy of an irradiance meter of high precision but has the advantage of being readily accessible on any smartphone. It could serve as a quick tool to estimate irradiance measurements in the preliminary stages of PV systems design. Furthermore, it could act as a cost-effective educational tool in sustainable energy courses where understanding solar radiation variations is an important aspect

    Georeferencing of Personal Exposure to Radiofrequency Electromagnetic Fields from Wi-Fi in a University Area

    No full text
    In the last two decades, due to the development of the information society, the massive increase in the use of information technologies, including the connection and communication of multiple electronic devices, highlighting Wi-Fi networks, as well as the emerging technological advances of 4G and 5G (new-generation mobile phones that will use 5G), have caused a significant increase in the personal exposure to Radiofrequency Electromagnetic Fields (RF-EMF), and as a consequence, increasing discussions about the possible adverse health effects. The main objective of this study was to measure the personal exposure to radiofrequency electromagnetic fields from the Wi-Fi in the university area of German Jordanian University (GJU) and prepare georeferenced maps of the registered intensity levels and to compare them with the basic international restrictions. Spot measurements were made outside the university area at German Jordanian University. Measurements were made in the whole university area and around two buildings. Two Satimo EME SPY 140 (Brest, France) personal exposimeters were used, and the measurements were performed in the morning and afternoon, and on weekends and weekdays. The total average personal exposure to RF-EMF from the Wi-Fi band registered in the three study areas and in the four days measured was 28.82 μW/m2. The average total exposure from the Wi-Fi band registered in the ten measured points of the university area of GJU was 22.97 μW/m2, the one registered in the eight measured points of building H was 34.48 μW/m2, and the one registered in the eight points of building C was 29.00 μW/m2. The maximum average values registered in the campus of GJU are below the guidelines allowed by International Commission on Non-ionizing Radiation Protection (ICNIRP). The measurement protocol used in this work has been applied in measurements already carried out in Spain and Mexico, and it is applicable in university areas of other countries
    corecore