5 research outputs found

    The European Registry for Patients with Mechanical Circulatory Support (EUROMACS)

    Get PDF
    OBJECTIVES: A second paediatric report has been generated from the European Registry for Patients with Mechanical Circulatory Support (EUROMACS). The purpose of EUROMACS, which is operated by the European Association for Cardio-Thoracic Surgery, is to gather data related to durable mechanical circulatory support for scientific purposes and to publish reports with respect to the course of mechanical circulatory support therapy. Since the first report issued, efforts to increase compliance and participation have been extended. Additionally, the data provided the opportunity to analyse patients of younger age and lower weight. METHODS: Participating hospitals contributed pre-, peri- and long-term postoperative data on mechanical circulatory support implants to the registry. Data for all implants in paediatric patients (≤19 years of age) performed from 1 January 2000 to 1 July 2019 were analysed. This report includes updates of patient characteristics, implant frequency, outcome (including mortality rates, transplants and recovery rates) as well as adverse events including neurological dysfunction, device malfunction, major infection and bleeding. RESULTS: Twenty-nine hospitals contributed 398 registered implants in 353 patients (150 female, 203 male) to the registry. The most frequent aetiology of heart failure was any form of cardiomyopathy (61%), followed by congenital heart disease and myocarditis (16.4% and 16.1%, respectively). Competing outcomes analysis revealed that a total of 80% survived to transplant or recovery or are ongoing; at the 2-year follow-up examination, 20% died while on support. At 12 months, 46.7% received transplants, 8.7% were weaned from their device and 18.5% died. The 3-month adverse events rate was 1.69 per patient-year for device malfunction including pump exchange, 0.48 for major bleeding, 0.64 for major infection and 0.78 for neurological events. CONCLUSIONS: The overall survival rate was 81.5% at 12 months following ventricular assist device implant. The comparison of survival rates of the early and later eras shows no significant difference. A focus on specific subgroups showed that survival was less in patients of younger age (<1 year of age) (P = 0.01) and lower weight (<20 kg) (P = 0.015). Transplant rates at 6 months contin

    The European Registry for Patients with Mechanical Circulatory Support (EUROMACS): first EUROMACS Paediatric (Paedi-EUROMACS) report

    No full text
    WOS: 000456105500002PubMed ID: 30184070OBJECTIVES: EUROMACS is a registry of the European Association for Cardio-Thoracic Surgery (EACTS) whose purpose is to gather clinical data related to durable mechanical circulatory support for scientific purposes and to publish annual reports. Because the treatment of children with end-stage heart failure has several significantly different characteristics than the treatment of adults, data and outcomes of interventions are analysed in this dedicated paediatric report. METHODS: Participating hospitals contributed pre-, peri- and long-term postoperative data on mechanical circulatory support implants to the registry. Data for all implants in paediatric patients (<= 19 years of age) performed from 1 January 2000 to 31 December 2017 were analysed. This report includes updates of patient characteristics, implant frequency, outcome (including mortality rates, transplants and recovery rates) as well as adverse events. RESULTS: Twenty-five hospitals contributed 237 registered implants in 210 patients (81 female, 129 male) to the registry. The most frequent diagnosis was any form of cardiomyopathy (71.4%) followed by congenital heart disease (18.6%). Overall mean support time on a device was 11.6 months (+/- 16.5 standard deviation). A total of 173 children (82.4%) survived to transplant, recovery or are ongoing; 37 patients (17.6%) died while on support within the observed follow-up time. At 12 months 38% of patients received transplants, 7% were weaned from their device and 15% died. At 24 months, 51% of patients received transplants, 17% died while on support, 22% were on a device and 9% were explanted due to myocardial recovery. The adverse events rate per 100 patient-months was 0.2 for device malfunction, 0.05 for major bleeding, 0.06 for major infection and 0.03 for neurological events within the first 3 months after implantation. CONCLUSIONS: The first paediatric EUROMACS report reveals a low transplant rate in European countries within the first 2 years of implantation compared to US data. The 1-year survival rate seems to be satisfactory. Device malfunction including pump chamber changes due to thrombosis was the most frequent adverse event.European Association for Cardio-Thoracic Surgery, EACTS; Stiftung Charite [BIH_ PRO_ 430]The European Association for Cardio-Thoracic Surgery, EACTS, supported this work. It was also supported in part by the Stiftung Charite [BIH_ PRO_ 430 to O.M.]
    corecore