8 research outputs found
Prostatic Artery Embolization as a Primary Treatment for Benign Prostatic Hyperplasia: Preliminary Results in Two Patients
Symptomatic benign prostatic hyperplasia (BPH) typically occurs in the sixth and seventh decades, and the most frequent obstructive urinary symptoms are hesitancy, decreased urinary stream, sensation of incomplete emptying, nocturia, frequency, and urgency. Various medications, specifically 5-α-reductase inhibitors and selective α-blockers, can decrease the severity of the symptoms secondary to BPH, but prostatectomy is still considered to be the traditional method of management. We report the preliminary results for two patients with acute urinary retention due to BPH, successfully treated by prostate artery embolization (PAE). The patients were investigated using the International Prostate Symptom Score, by digital rectal examination, urodynamic testing, prostate biopsy, transrectal ultrasound (US), and magnetic resonance imaging (MRI). Uroflowmetry and postvoid residual urine volume complemented the investigation at 30, 90, and 180 days after PAE. The procedure was performed under local anesthesia; embolization of the prostate arteries was performed with a microcatheter and 300- to 500-μm microspheres using complete stasis as the end point. One patient was subjected to bilateral PAE and the other to unilateral PAE; they urinated spontaneously after removal of the urethral catheter, 15 and 10 days after the procedure, respectively. At 6-month follow-up, US and MRI revealed a prostate reduction of 39.7% and 47.8%, respectively, for the bilateral PAE and 25.5 and 27.8%, respectively, for the patient submitted to unilateral PAE. The early results, at 6-month follow-up, for the two patients with BPH show a promising potential alternative for treatment with PAE
Contribution of sonographic contrast media in assessment of pancreatic transplantation
INTRODUÇÃO: O transplante de pâncreas é a opção definitiva para a manutenção do estado normoglicêmico permanente nos portadores de diabetes mellitus tipo 1. O meio de contraste de ultra-som é uma metodologia capaz de avaliar a perfusão tecidual, mas não há um estudo para a avaliação do padrão de perfusão do pâncreas transplantado normal e patológico. A importância da avaliação da perfusão do enxerto e a aplicação do meio de contraste por microbolhas foram os motivos para a realização desta pesquisa. Este estudo, desenvolvido no Instituto de Radiologia do Hospital das Clínicas da Faculdade de Medicina da Universidade de São Paulo no período de novembro de 2004 a setembro de 2006 objetivou: A) estabelecer os padrões de vascularização do enxerto nos pacientes normais e naqueles com suspeita de complicações; B) comparar os achados de exames laboratoriais, uso ou não de insulina exógena e situação clínica dos pacientes com os achados da ultra-sonografia modo-B e com meio de contraste por microbolhas; C) Estabelecer o valor da ultra-sonografia com meio de contraste de microbolhas (USMCM) na avaliação do pâncreas transplantado. CASUÍSTICA e MÉTODOS: Vinte e seis pacientes foram submetidos ao exame de ultra-sonografia com contraste em um total de trinta estudos, 20 (66,7%) em homens e 10 (33,3%) em mulheres. A idade dos pacientes variou de 25 a 51 anos, com média de idade de 40 anos (+ 7,3 anos). O tempo médio da realização do transplante até a realização do estudo variou de um dia a 63 meses (mediana de 24 meses). Ao modo-B, o pâncreas foi analisado quanto a ecogenicidade, dimensões (avaliação qualitativa e quantitativa) e contornos. Após a administração do meio de contraste, observou-se o tempo de chegada do meio de contraste no pâncreas, o padrão e a intensidade de realce. Após esta avaliação foi realizada uma classificação baseada nos achados do modo-B e contraste nas seguintes possibilidades: padrão de perfusão normal, alterações agudas (rejeição, pancreatite ou trombose) ou alterações crônicas (rejeição crônica). RESULTADOS: Observou-se associação estatisticamente significante entre a ecogenicidade e a situação clínica (p=0,010); ecogenicidade e uso de insulina (p= 0,021); dimensões (avaliação qualitativa) e situação clinica (p=0,011); dimensões (avaliação qualitativa) e uso de insulina (p=0,028); padrão de realce (p=0,024) e intensidade do realce com a situação clínica (p=0,039). Houve associação estatisticamente significante também entre o uso ou não de insulina exógena com a perfusão do enxerto (p=0,014) e a hipótese diagnóstica (ultra-som) (p=0,001). CONCLUSÃO: Os padrões de vascularização do pâncreas transplantado normais e naqueles com suspeita de complicações foram estabelecidos. Os critérios de ecogenicidade e a avaliação qualitativa das dimensões do pâncreas ao ultra-som modo-B se mostraram adequados na diferenciação entre estudos normais e alterados. A ultra-sonografia com meio de contraste de microbolhas foi útil na diferenciação entre estudos normais e alterados do pâncreas transplantado, utilizando os critérios de padrão do realce, intensidade do realce e perfusão do enxerto na fase arterial.INTRODUCTION: Pancreatic transplantation is the long-term therapeutic option for maintaining normoglycemic status in patients with type 1 diabetes mellitus. Sonographic contrast medium allows to evaluate tissue perfusion but there are no studies comparing this parameter in normal and pathologic pancreatic grafts in the literature at the time of this writing. The importance of assessment of graft perfusion and the potential role of contrast-enhanced sonography with microbubbles in this regard were the reasons for this research. The study conducted at the Instituto de Radiologia do Hospital das Clínicas da Faculdade de Medicina da Universidade de São Paulo between November, 2004 and September, 2006 had the following objectives: A) to establish patterns of graft vascularization in normal patients and in those with suspected abnormalities; B) to compare grayscale mode and contrastenhanced sonographic findings with clinical status, laboratory results, and need for exogenous insulin; C) to define the role of contrast-enhanced sonography with microbubbles in the evaluation of pancreatic transplantation.MATERIALS AND METHODS: Twenty-six patients underwent a total of 30 sonographic examinations with microbubbles, 20 (66.7%) men and 10 (33.3%) women. Age range was 25 to 51 years, with a mean of 40 years (+ 7.3 years). Time elapsed between transplantation and imaging ranged from 1 day to 63 months (median, 24 months). Using grayscale mode, pancreas was assessed for echogenicity, dimensions (both quantitatively and qualitatively) and contours. Following intravenous contrast medium administration, time for enhancement of the pancreatic graft, pattern and intensity of enhancement were documented. A classification system based on grayscale and contrast-enhanced sonographic findings was designed, with the following categories: normal perfusion pattern, acute changes (rejection, pancreatitis or thrombosis) and chronic changes (chronic rejection). RESULTS: There was a statistically significant association between echogenicity and clinical status (p=0.010); echogenicity and need for exogenous insulin (p=0.021); dimensions (qualitative criteria) and clinical status (p=0.011); dimensions (qualitative criteria) and need for exogenous insulin (p=0.028); pattern (p=0.024) and intensity of enhancement versus clinical status (p=0.039). There was also statistically significant association between need for exogenous insulin and graft perfusion (p=0.014), and sonography-based diagnosis (p=0.001). CONCLUSION: The study provided patterns of vascularization in normal pancreatic grafts and in patients with suspected abnormalities. Distinction of normal and abnormal pancreatic grafts was possible using echogenicity and qualitative analysis of graft size on grayscale mode. Contrast-enhanced sonography with microbubbles also contributed to differentiation between normal and abnormal pancreatic grafts, using pattern and intensity of enhancement and perfusion of the graft during the arterial phase
Parâmetros dopplervelocimétricos na avaliação da perviedade da anastomose portossistêmica intra-hepática transjugular (TIPS): estudo prospectivo Doppler flowmeter parameters for evaluation of transjugular intrahepatic porto-systemic shunts (TIPS) patency: prospective study
OBJETIVO: Estudar as alterações hemodinâmicas consideradas normais após a realização da anastomose portossistêmica intra-hepática transjugular (TIPS) e a eficácia dos parâmetros sugestivos de estenose do TIPS com o ultra-som Doppler. MATERIAIS E MÉTODOS: Dezesseis pacientes foram avaliados de maneira prospectiva, no período de dezembro de 2001 a março de 2003. As avaliações foram realizadas 24-48 horas após o TIPS e a seguir em intervalos regulares de 30 dias, três meses, seis meses e um ano, com ultra-som modo B, Doppler pulsado, Doppler colorido e de amplitude em diferentes pontos da prótese relacionados ao TIPS. A angiografia foi realizada apenas para a confirmação dos resultados e terapêutica pertinente. RESULTADOS: Até o momento apenas os achados de fluxo contínuo no terço proximal da prótese e o gradiente de velocidade entre dois pontos da prótese apresentaram significância estatística para o diagnóstico de estenose do TIPS (p < 0,001), mas outros diferentes critérios também estiveram presentes, porém sem significância estatística. CONCLUSÃO: O ultra-som Doppler é uma ferramenta eficaz no diagnóstico da perviedade e das complicações secundárias à realização do TIPS, sobretudo da estenose. No entanto, é necessária casuística maior, a fim de determinar um conjunto de parâmetros que facilite o seguimento destes pacientes, reservando a angiografia apenas para o tratamento pertinente.<br>OBJECTIVE: To assess the hemodynamic changes considered normal after transjugular intrahepatic porto-systemic shunt (TIPS) placement and the efficacy of TIPS parameters suggestive of stenosis using Doppler sonography. MATERIALS AND METHODS: Sixteen patients were prospectively evaluated from December, 2001 to March, 2003 after TIPS placement. Evaluations were performed 24 to 48 hours after the procedure and then at intervals of 30 days, three months, six months and one year using B mode, color Doppler, power Doppler and spectral Doppler in different TIPS related sites. Angiography was performed only to confirm Doppler findings and treatment. RESULTS: To date the only statistically significant parameters for diagnosis of TIPS stenosis were continuous flow pattern in the proximal third of TIPS and the velocity gradient between the two sites (p < 0.001). Different non-statistically significant parameters were also observed. CONCLUSION: Doppler sonography is an efficient tool for the diagnosis of shunt patency and TIPS related complications such as stenosis. However, it is necessary to study a larger number of patients in order to determine a group of parameters that would help in the follow-up of these patients, thus using portal angiography only for indicated treatment
Parâmetros dopplervelocimétricos na avaliação da perviedade da anastomose portossistêmica intra-hepática transjugular (TIPS) Dopplerflowmetric patterns for evaluation of transjugular intrahepatic portosystemic shunt patency
A anastomose portossistêmica intra-hepática transjugular (TIPS) é um procedimento intervencionista minimamente invasivo realizado pela introdução de prótese metálica auto-expansível no parênquima hepático, via transjugular. Tem por objetivo tratar as complicações da hipertensão portal, principalmente a hemorragia digestiva alta e a ascite refratária. A estenose é complicação freqüente, embora o procedimento seja eficaz e com baixo índice de insucesso. O diagnóstico precoce da estenose é de fundamental importância, pois interfere no tipo de tratamento a ser realizado e o reaparecimento dos sintomas pode ser grave. O ultra-som Doppler é então utilizado para o seguimento dos pacientes portadores do TIPS, e vários parâmetros são descritos na literatura para o diagnóstico de estenose, como: as velocidades mínima e máxima no interior da prótese, a velocidade na veia porta, o gradiente de velocidade entre dois pontos da prótese, e outros. Infelizmente não há consenso sobre qual parâmetro ou conjunto de parâmetros é mais eficaz no diagnóstico, porque os protocolos de avaliação variam de instituição para instituição. Os autores realizaram uma revisão dos parâmetros de estenose descritos na literatura e de outros aspectos de fundamental importância na compreensão do procedimento, como as indicações, as contra-indicações e a fisiopatologia da estenose.<br>Transjugular intrahepatic portosystemic shunt (TIPS) is a minimally invasive interventional procedure that consists of placement of an auto expandable metallic stent in the hepatic parenchyma via transjugular. It is used to treat the complications of portal hypertension, particularly digestive bleeding of gullet varices and refractory ascites. Although TIPS is an efficient procedure with low rate of failure some complications such as stenosis are frequent. Early diagnosis of stenosis is mandatory since it interferes with the type of treatment and the reappearing symptoms can be serious. Doppler sonography is used in the follow-up of this patients and many parameters indicating TIPS stenosis are described in the literature such as the minimum and maximum velocity flow inside the stent, the velocity flow in portal vein, the velocity gradient between different sites of the stent, among others. Unfortunately there is no consensus on which parameter or group of parameters is more efficient for diagnosis because the evaluation protocols varied among institutions. The authors reviewed the parameters of stenosis reported in literature and other important aspects for comprehension of this procedure including indications, contraindications and physiopathology of stenosis