12 research outputs found

    Five-year outcomes of chronic total occlusion treatment with a biolimus A9-eluting biodegradable polymer stent versus a sirolimus-eluting permanent polymer stent in the LEADERS all-comers trial

    Get PDF
    Background: Few data are available on long-term follow-up of drug-eluting stents in the treatment of chronic total occlusion (CTO). The LEADERS CTO sub-study compared the long-term results in CTO and non-CTO lesions of a Biolimus A9™-eluting stent (BES) with a sirolimus-eluting stent (SES).Methods: Among 1,707 patients enrolled in the prospective, multi-center, all-comers LEADERS trial, 81 with CTOs were treated with either a BES (n = 45) or a SES (n = 36). The primary endpoint was the occurrence of major adverse cardiac events (MACE): cardiac death, myocardial infarction (MI) and clinically-indicated target vessel revascularization (TVR).Results: At 5 years, the rate of MACE was numerically higher in the CTO group than in the non-CTO group (29.6% vs. 23.3%; p = 0.173), with a significant increase in the incidence of target lesion revascularization (TLR) (21.0 vs. 12.6; p = 0.033), but no difference in stent thrombosis (ST). Patients with CTO receiving a BES demonstrated a lower incidence of MACE (22.2% vs. 38.9%; p = 0.147) with a significant reduction in TLR compared to patients receiving a SES (11.1% vs. 33.3%, p = 0.0214) with an incidence similar to that observed in the non-CTO group treated with BES (11.6%). Definite ST at 5 years nearly halved in the BES group (4.4% vs. 8.3%, p = 0.478) with no ST in the BES group after the first year (0% vs. 8.3%, p for interaction = 0.009).Conclusions: The use of a BES showed a reduction in MACE, TVR, TLR, and ST over time in the CTO subset with similar outcome as for non-CTO lesions

    Five-year outcomes of chronic total occlusion treatment with a biolimus A9-eluting biodegradable polymer stent versus a sirolimus-eluting permanent polymer stent in the LEADERS all-comers trial.

    Get PDF
    BACKGROUND Few data are available on long-term follow-up of DES in the treatment of chronic total occlusion (CTO). The LEADERS CTO sub-study compared the long-term results in CTO and non-CTO lesions of a Biolimus A9™-eluting stent (BES) with a sirolimus-eluting stent (SES). METHODS Among 1,707 patients enrolled in the prospective, multi-center, all-comers LEADERS trial, 81 with CTOs were treated with either a BES (n = 45) or a SES (n = 36). The primary endpoint was the occurrence of major adverse cardiac events (MACE): cardiac death, myocardial infarction (MI) and clinically-indicated target vessel revascularization (TVR). RESULTS At 5 years, the rate of MACE was numerically higher in the CTO group than in the non-CTO group (29.6% vs. 23.3%; p = 0.173), with a significant increase in the incidence of target lesion revascularization (TLR) (21.0 vs. 12.6; p = 0.033), but no difference in stent thrombosis (ST). Patients with CTO receiving a BES demonstrated a lower incidence of MACE (22.2% vs. 38.9%; p = 0.147) with a significant reduction in TLR compared to patients receiving a SES (11.1% vs. 33.3%, p = 0.0214) with an incidence similar to that observed in the non-CTO group treated with BES (11.6%). Definite ST at 5 years nearly halved in the BES group (4.4% vs. 8.3%, p = 0.478) with no ST in the BES group after the first year (0% vs. 8.3%, p for interaction = 0.009). CONCLUSIONS The use of a BES showed a reduction in MACE, TVR, TLR, and ST over time in the CTO subset with similar outcome as for non-CTO lesions

    Platelet reactivity in patients with acute coronary syndrome treated with prasugrel or ticagrelor in comparison to clopidogrel: a retrospective pharmacodynamic analysis

    Full text link
    Dual antiplatelet therapy (DAPT) with aspirin and a P2Y12 inhibitor is a mainstay of the prevention of stent thrombosis following percutaneous coronary intervention (PCI). In the 2015 European guidelines for the management of acute coronary syndrome (ACS), prasugrel (PRA) and ticagrelor (TICA) combined with aspirin are recommended as first-line therapy. Clopidogrel (CLO) is recommended as an alternative medication for patients with contradictions to these new drugs. This single-center study analyzed the platelet function of 809 ACS patients undergoing PCI and treatment with DAPT. The platelet response to ADP was determined using Multiplate® analyzer at a median of 3 days after PCI in 254 patients treated with PRA (loading dose [LD] 60 mg, 10 mg qd), 162 patients receiving TICA (LD 180 mg, D 90 mg bid), and 393 CLO-treated patients (LD 600 mg, 75 mg qd). An aggregation >468 arbitrary units (AU)*min was defined as “high on-treatment platelet reactivity” (HPR), <188 AU*min as “low on-treatment platelet reactivity” (LPR). Platelet response in PRA-treated patients was lower compared to CLO or TICA (median; interquartile range: PRA 220 [163–275] AU*min vs. CLO 268 [186–387] AU*min, p < 0.001 vs. TICA 245 [190–320] AU*min, p = 0.001). Only 1.6% of PRA patients were stratified as HPR and 34.6% as LPR, while in the TICA group 1.9% fulfilled the criteria of HPR and 24.1% criteria of LPR. Sixteen percent of CLO patients were stratified as HPR and 26.2% as LPR. In a real-world cohort of ACS patients following PCI, PRA results in more potent inhibition of platelet function compared to CLO and TICA. TICA achieves a consistent antiplatelet effect with reduced rates of HPR and LPR in relation to CLO

    Original Article A prospective, non-randomized comparison of SAPIEN XT and CoreValve implantation in two sequential cohorts of patients with severe aortic stenosis

    Full text link
    Abstract: Objectives: Few data is available comparing Edwards SAPIEN XT -SXT (Edwards Lifesciences, Irvine, California) with Medtronic CoreValve -CoV (Medtronic Inc., Minneapolis, Minnesota) in patients with severe aortic stenosis undergoing transcatheter aortic valve replacement (TAVR). Methods: We selected consecutive patients undergoing transfemoral TAVR with SXT or CoV at our Institution. Main outcomes were Valve Academic Research Consortium (VARC)-combined safety endpoints. Results: A total of 100 patients (SXT, n=50 versus CoV, n=50) were analyzed. Both SXT and CoV showed good device success rates (98% versus 90%, p=0.20). SXT versus CoV reduced the occurrence of paravalvular regurgitation after TAVR (26% versus 90%, p&lt;0.0001) though not affecting the rate of moderate/severe regurgitation (p=0.20). SXT versus CoV required less frequently a permanent pacemaker after TAVR (8% versus 38%, p&lt;0.0001). In-hospital major vascular complications (8% versus 4%, p&gt;0.99), lifethreatening bleedings (2% versus 4%, p&gt;0.99), stroke (4% versus 6%, p&gt;0.99) and death (6% versus 2%, p&gt;0.99) did not differ between SXT and CoV. However, safety endpoints favored SXT (17% versus 34.6%, p=0.01), due to a numerically higher incidence of ischemic stroke and Acute Kidney Injury Stage 3 after CoV. At multivariate analysis, TAVR with SXT (odds ratio=0.21, 95% confidence intervals [0.05-0.84], p=0.03) was predictive of fewer adverse events. Conclusions: Transcatheter valve implantation with Edwards SAPIEN XT was associated with lower VARCcombined safety endpoints as compared with Medtronic CoreValve. More extensive cohorts are needed to confirm these results

    Biolimus-eluting stent with biodegradable polymer improves clinical outcomes in patients with acute myocardial infarction

    Get PDF
    OBJECTIVE To investigate clinical outcomes of coronary intervention using a biolimus-eluting stent (BES) compared with a sirolimus-eluting stent (SES) in patients with acute myocardial infarction (AMI) in the Limus Eluted from A Durable versus ERodable Stent (LEADERS) coating trial at the final 5-year follow-up. METHODS The LEADERS trial is a multicentre all-comer study, where patients (n=1707) were randomised to percutaneous intervention with either BES containing biodegradable polymer or SES containing durable polymer. Out of 1707 patients enrolled in this trial, 573 patients had percutaneous coronary intervention for AMI (BES=280, SES=293) and were included in the current analysis. Patient-oriented composite endpoint (POCE, including all death, all myocardial infarction (MI) and all revascularisations), major adverse cardiac events (MACE, including cardiac death, MI and clinically indicated target vessel revascularisation) and stent thrombosis were assessed at 5-year follow-up. RESULTS The baseline clinical, angiographic and procedural characteristics were well matched between BES and SES groups. In all patients with AMI, coronary intervention with a BES, compared with SES, significantly reduced POCE (28.9% vs 42.3%; relative risk (RR) 0.61, 95% CI 0.47 to 0.82, p=0.001) at 5-year follow-up. There was also a reduction in MACE rate in the BES group (18.2% vs 25.9%; RR 0.67, 95% CI 0.47 to 0.95, p=0.025); however, there was no difference in cardiac death and stent thrombosis. In patients with ST-elevation MI (STEMI), coronary intervention with BES significantly reduced POCE (24.4% vs 39.3%; RR 0.55, 95% CI 0.36 to 0.85, p=0.006), MACE (12.6% vs 25.0%; RR 0.47, 95% CI 0.26 to 0.83, p=0.008) and cardiac death (3.0% vs 11.4%; RR 0.25, 95% CI 0.08 to 0.75, p=0.007), along with a trend towards reduction in definite stent thrombosis (3.7% vs 8.6%; RR 0.41, 95% CI 0.15 to 1.18, p=0.088), compared with SES. CONCLUSIONS BES, compared with SES, significantly improved safety and efficacy outcomes in patients with AMI, especially those with STEMI, at 5-year follow-up. TRIAL REGISTRATION NUMBER NCT 00389220

    Long-term clinical outcomes of biodegradable polymer biolimus-eluting stents versus durable polymer sirolimus-eluting stents in patients with coronary artery disease (LEADERS): 4 year follow-up of a randomised non-inferiority trial

    Get PDF
    Background The effectiveness of durable polymer drug-eluting stents comes at the expense of delayed arterial healing and subsequent late adverse events such as stent thrombosis (ST). We report the 4 year follow-up of an assessment of biodegradable polymer-based drug-eluting stents, which aim to improve safety by avoiding the persistent inflammatory stimulus of durable polymers. Methods We did a multicentre, assessor-masked, non-inferiority trial. Between Nov 27, 2006, and May 18, 2007, patients aged 18 years or older with coronary artery disease were randomly allocated with a computer-generated sequence to receive either biodegradable polymer biolimus-eluting stents (BES) or durable polymer sirolimus-eluting stents (SES; 1:1 ratio). The primary endpoint was a composite of cardiac death, myocardial infarction, or clinically-indicated target vessel revascularisation (TVR); patients were followed-up for 4 years. Analysis was by intention to treat. This trial is registered with ClinicalTrials.gov, number NCT00389220. Findings 1707 patients with 2472 lesions were randomly allocated to receive either biodegradable polymer BES (857 patients, 1257 lesions) or durable polymer SES (850 patients, 1215 lesions). At 4 years, biodegradable polymer BES were non-inferior to durable polymer SES for the primary endpoint: 160 (18·7%) patients versus 192 (22·6%) patients (rate ratios [RR] 0·81, 95% CI 0·66–1·00, p for non-inferiority <0·0001, p for superiority=0·050). The RR of definite ST was 0·62 (0·35–1·08, p=0·09), which was largely attributable to a lower risk of very late definite ST between years 1 and 4 in the BES group than in the SES group (RR 0·20, 95% CI 0·06–0·67, p=0·004). Conversely, the RR of definite ST during the first year was 0·99 (0·51–1·95; p=0·98) and the test for interaction between RR of definite ST and time was positive (pinteraction=0·017). We recorded an interaction with time for events associated with ST but not for other events. For primary endpoint events associated with ST, the RR was 0·86 (0·41–1·80) during the first year and 0·17 (0·04–0·78) during subsequent years (pinteraction=0·049). Interpretation Biodegradable polymer BES are non-inferior to durable polymer SES and, by reducing the risk of cardiac events associated with very late ST, might improve long-term clinical outcomes for up to 4 years compared with durable polymer SES. Funding Biosensors Europe SA, Switzerland

    Improved safety and reduction in stent thrombosis associated with biodegradable polymer-based biolimus-eluting stents versus durable polymer-based sirolimus-eluting stents in patients with coronary artery disease: final 5-year report of the LEADERS (Limus Eluted From A Durable Versus ERodable Stent Coating) randomized, noninferiority trial

    Get PDF
    OBJECTIVES This study sought to report the final 5 years follow-up of the landmark LEADERS (Limus Eluted From A Durable Versus ERodable Stent Coating) trial. BACKGROUND The LEADERS trial is the first randomized study to evaluate biodegradable polymer-based drug-eluting stents (DES) against durable polymer DES. METHODS The LEADERS trial was a 10-center, assessor-blind, noninferiority, "all-comers" trial (N = 1,707). All patients were centrally randomized to treatment with either biodegradable polymer biolimus-eluting stents (BES) (n = 857) or durable polymer sirolimus-eluting stents (SES) (n = 850). The primary endpoint was a composite of cardiac death, myocardial infarction (MI), or clinically indicated target vessel revascularization within 9 months. Secondary endpoints included extending the primary endpoint to 5 years and stent thrombosis (ST) (Academic Research Consortium definition). Analysis was by intention to treat. RESULTS At 5 years, the BES was noninferior to SES for the primary endpoint (186 [22.3%] vs. 216 [26.1%], rate ratio [RR]: 0.83 [95% confidence interval (CI): 0.68 to 1.02], p for noninferiority <0.0001, p for superiority = 0.069). The BES was associated with a significant reduction in the more comprehensive patient-orientated composite endpoint of all-cause death, any MI, and all-cause revascularization (297 [35.1%] vs. 339 [40.4%], RR: 0.84 [95% CI: 0.71 to 0.98], p for superiority = 0.023). A significant reduction in very late definite ST from 1 to 5 years was evident with the BES (n = 5 [0.7%] vs. n = 19 [2.5%], RR: 0.26 [95% CI: 0.10 to 0.68], p = 0.003), corresponding to a significant reduction in ST-associated clinical events (primary endpoint) over the same time period (n = 3 of 749 vs. n = 14 of 738, RR: 0.20 [95% CI: 0.06 to 0.71], p = 0.005). CONCLUSIONS The safety benefit of the biodegradable polymer BES, compared with the durable polymer SES, was related to a significant reduction in very late ST (>1 year) and associated composite clinical outcomes. (Limus Eluted From A Durable Versus ERodable Stent Coating [LEADERS] trial; NCT00389220)
    corecore