207 research outputs found
Dyssynchrony and the risk of ventricular arrhythmias
OBJECTIVES: The aim of our study was to evaluate the relationship between left ventricular (LV) dyssynchrony and the risk of ventricular tachycardia (VT) or ventricular fibrillation (VF) in patients enrolled in the MADIT-CRT (Multicenter Automatic Defibrillator Implantation Trial-Cardiac Resynchronization Therapy) trial. BACKGROUND: Intraventricular mechanical dyssynchrony might be an important factor in ventricular arrhythmogenesis by enhancing electrical heterogeneity in heart failure patients. The effects of dyssynchrony have not yet been evaluated in a large cohort of implantable cardioverter-defibrillator (ICD) and cardiac resynchronization therapy with defibrillator (CRT-D) patients. METHODS: LV dyssynchrony was measured at baseline and at 12-months by speckle-tracking echocardiography, defined as the standard deviation of time to peak systolic strain in 12 LV myocardial segments. The endpoint was the first VT/VF/death or VT/VF. LV dyssynchrony was evaluated in 764 left bundle branch block (LBBB) patients and in 312 non-LBBB patients. RESULTS: Baseline LV dyssynchrony was not predictive of VT/VF/death or VT/VF in LBBB or non-LBBB patients in either treatment arm. In CRT-D patients with LBBB, improvement in LV dyssynchrony over a year was associated with significantly lower incidence of VT/VF/death (p < 0.001) and VT/VF (p < 0.001) compared to ICD patients and to CRT-D patients with unchanged or worsening dyssynchrony. Among LBBB patients, 15% decrease in LV dyssynchrony was associated with lower risk of VT/VF/death (hazard ratio: 0.49, 95% confidence interval: 0.24 to 0.99, p = 0.049) and VT/VF (hazard ratio: 0.30, 95% confidence interval: 0.12 to 0.77, p = 0.009) as compared to ICD patients. Patients without LBBB receiving CRT-D did not show reduction in VT/VF/death or in VT/VF in relation to improving dyssynchrony when evaluating cumulative event rates or risk of events. CONCLUSIONS: Baseline LV dyssynchrony did not predict VT/VF/death or VT/VF in mild heart failure patients with or without LBBB. CRT-induced improvement of LV dyssynchrony was associated with significant reduction of ventricular arrhythmias in patients with LBBB. (Multicenter Automatic Defibrillator Implantation Trial With Cardiac Resynchronization Therapy [MADIT-CRT]; NCT00180271)
Clinical and Hemodynamic Effects of Percutaneous Edge-to-Edge Mitral Valve Repair in Atrial Versus Ventricular Functional Mitral Regurgitation.
The present study aims to assess the clinical and hemodynamic impact of percutaneous edge-to-edge mitral valve repair with MitraClip in patients with atrial functional mitral regurgitation (A-FMR) compared with ventricular functional mitral regurgitation (V-FMR). Mitral regurgitation (MR) grade, functional status (New York Heart Association class), and major adverse cardiac events (MACE; all-cause mortality or hospitalization for heart failure) were evaluated in 52 patients with A-FMR and in 307 patients with V-FMR. In 56 patients, hemodynamic assessment during exercise echocardiography was performed before and 6 months after intervention. MR reduction after MitraClip implantation was noninferior in A-FMR compared with V-FMR (MR grade ≤2 at 6 months in 94% vs 82%, respectively, p <0.001 for noninferiority) and was associated with improvement of functional status (New York Heart Association class ≤2 at 6 months in 90% vs 80%, respectively, p = 0.2). Hemodynamic assessment revealed that cardiac output at 6 months was higher in A-FMR at rest (5.1 ± 1.5 L/min vs 3.8 ± 1.5 L/min, p = 0.002) and during peak exercise (7.9 ± 2.4 L/min vs 6.1 ± 2.1 L/min, p = 0.02). In addition, the reduction in systolic pulmonary artery pressure at rest was more pronounced in A-FMR: Δ SPAP -13.1 ± 15.1 mm Hg versus -2.2 ± 13.3 mm Hg (p = 0.03). MACE rate at follow-up was significantly lower in A-FMR versus V-FMR, with an adjusted odds ratio of 0.46 (95% confidence interval 0.24 to 0.88), which was caused by a reduction in hospitalization for heart failure. In conclusion, percutaneous edge-to-edge mitral valve repair with MitraClip is at least as effective in A-FMR as in V-FMR in reducing MR. However, the hemodynamic improvement and reduction of MACE were significantly better in A-FMR
Les nouvelles recommandations de l’insuffisance cardiaque en 2023
[Revivre le WEBINAIRE du Louvain Médical du 14 novembre 2023] Les nouvelles recommandations de l’insuffisance cardiaque émises par la Société Européenne de Cardiologie en 2021 et l’update plus récent en 2023 marquent une nouvelle étape dans la gestion de cette pathologie complexe
- …