4 research outputs found

    Finite Element Analysis to determine the optimum contact pressure between the components of a hip implant made by using the Selective Laser Sintering and the Selective Laser Melting Technologies

    No full text
    The article presents a case study that was realized at the Technical University of Cluj-Napoca (TUC-N) in the field of customized medical implants made by using different additive manufacturing (AM) technologies, such as the Selective Laser Sintering (SLS) and the Selective Laser Melting (SLM). Finite element analysis was successfully used to determine the mechanical behavior of an acetabular liner that was made from PA 2200 powder material by SLS and to determine the optimum technological parameters required to be used in the manufacturing process of the acetabular liner by SLS, so as the contact pressure between the acetabular liner made from PA 2200 material by SLS and the femoral head made from TiAl6V4 material by SLM will be optimum at the end and the displacement between the components will remain in the admissible limits

    The influence of build orientation on the mechanical properties of medical implants made from PA 2200 by Selective Laser Sintering

    No full text
    This paper presents a series of research that have been made by the authors in the field of medical implants realized from PA 2200 powder material using the Selective Laser Sintering (SLS) method. Several sets of samples differently oriented into the working area of the machine were manufactured from PA 2200 by SLS, in order to determine which is the recommended orientation to be used during the manufacturing process, in such a way that at the end the mechanical properties (e.g. Compressive strength, Young’s modulus, etc.) will be as closed as possible to the ones of the human bones. The obtained results were further on used in the case of a medical implant (Acetabular liner) that was manufactured at the Technical University of Cluj-Napoca (TUCN) from PA 2200 material using the DTM Sinterstation 2000 SLS equipment

    Selective Laser Sintering of PA 2200 for Hip Implant Applications: Finite Element Analysis, Process Optimization, Morphological and Mechanical Characterization

    No full text
    Polyamide 12 (PA 22000) is a well-known material and one of the most biocompatible materials tested and used to manufacture customized medical implants by selective laser sintering technology. To optimize the implants, several research activities were considered, starting with the design and manufacture of test samples made of PA 2200 by selective laser sintering (SLS) technology, with different processing parameters and part orientations. The obtained samples were subjected to compression tests and later to SEM analyses of the fractured zones, in which we determined the microstructural properties of the analyzed samples. Finally, an evaluation of the surface roughness of the material and the possibility of improving the surface roughness of the realized parts using finite element analysis to determine the optimum contact pressure between the component made of PA 2200 by SLS and the component made of TiAl6V4 by SLM was performed
    corecore