6 research outputs found

    Evaluation of Electroless Nickel Poly alloys for Drilling of CFRP

    No full text
    Today even though composites have wide range of applications in aerospace and other industries, machining of composites is still considered to be a difficult task. In this study, efforts are made to reduce drill bit wear characteristics during machining of CFRP composite. Electroless coating method is used to coat nano-crystalline ternary Ni-W-P coating on HSS drill bits of diameter 7mm, to carry out drilling operations on CFRP. The coatings are characterised by their morphology, composition, structure, phase transformation behaviour and nano-hardness. By subsequent pre-treatment steps, Ni-W-P coatings are adhered on HSS drill bits and coarse nodular structures were observed upon surface testing by using FESEM. About 14.5 weight% of W, 5.41 weight% of P with balance of Ni was observed in the compositional analysis of the deposit carried out by EDAX. With constant feed and speed, drilling operation carried out on CFRP plate of thickness 2.5 mm and drill bit characteristics were evaluated. HSS drill bits of type uncoated, Ni-W-P coated and heat treated were used for drilling CFRP plate. Drill bits tool wear were examined by using Tool Makers Microscope. The drilling operation is carried out to drill 100 holes on CFRP plate by all types of drill bits and the drill bits were examined at every 20 intervals of drilling. It was found that Ni-W-P coated drill bits have shown about 60% reduction (0.2mm less) in chisel edge wear, about 40% (0.1mm) lower wear on cutting edge and about 60% (0.5mm) less wear on flank surface compared to uncoated and heat treated drill bits. Based on the results obtained in this study, electroless ternary Ni-W-P coating seems to be most likely material which enhances the tool life and gives better quality machining

    An omental teratoma in a young girl

    No full text
    Teratoma is the most commonly encountered germ cell tumour among the most common ovarian tumours; however, teratomas of the omentum and mesentery are extremely rare. They are usually asymptomatic or can produce compressive symptoms. The imaging features are suggestive. The present report describes such a case of primary omental teratoma encountered in a young patient, which was managed by surgical resection. The histopathological examination confirmed the diagnosis of mature cystic teratoma. Germ cell tumors are congenital tumors containing derivatives of all the three germinal layers, frequently seen in gonads. But their occurrence in extragonadal sites, such as omental teratoma, is relatively rare

    Evaluation of Electroless Nickel Poly alloys for Drilling of CFRP

    No full text
    Today even though composites have wide range of applications in aerospace and other industries, machining of composites is still considered to be a difficult task. In this study, efforts are made to reduce drill bit wear characteristics during machining of CFRP composite. Electroless coating method is used to coat nano-crystalline ternary Ni-W-P coating on HSS drill bits of diameter 7mm, to carry out drilling operations on CFRP. The coatings are characterised by their morphology, composition, structure, phase transformation behaviour and nano-hardness. By subsequent pre-treatment steps, Ni-W-P coatings are adhered on HSS drill bits and coarse nodular structures were observed upon surface testing by using FESEM. About 14.5 weight of W, 5.41 weight of P with balance of Ni was observed in the compositional analysis of the deposit carried out by EDAX. With constant feed and speed, drilling operation carried out on CFRP plate of thickness 2.5 mm and drill bit characteristics were evaluated. HSS drill bits of type uncoated, Ni-W-P coated and heat treated were used for drilling CFRP plate. Drill bits tool wear were examined by using Tool Makers Microscope. The drilling operation is carried out to drill 100 holes on CFRP plate by all types of drill bits and the drill bits were examined at every 20 intervals of drilling. It was found that Ni-W-P coated drill bits have shown about 60 reduction (0.2mm less) in chisel edge wear, about 40 (0.1mm) lower wear on cutting edge and about 60 (0.5mm) less wear on flank surface compared to uncoated and heat treated drill bits. Based on the results obtained in this study, electroless ternary Ni-W-P coating seems to be most likely material which enhances the tool life and gives better quality machining. Selection and Peer-review under responsibility of Advanced Materials, Manufacturing, Management and Thermal Science (AMMMT 2016)

    Unilobar multiple cerebral hydatid cyst: A rare disease

    No full text

    Rural Centre Based Management of the Carotid Body Tumour

    No full text
    A 40 year old male patient reported to our rural based hospital with a complaint of discomfort associated with a swelling on the left side of the neck since 8 years. A provisional diagnosis of a carotid body tumour was made based on clinical examination and ultrasound examination. Higher investigations could not be performed due to unavailability at the rural setup and referral to a specialty centre was not possible due to financial constraints of the patient. Even with advances in diagnostic and surgical techniques, surgery still presents a major threat of injury to the cranial nerves. Nevertheless, it remains the preferred method of treatment for these tumours. Our case shows that such masses can be removed successfully and that, with care, the cranial nerves and the carotid arteries can be preserved at the rural hospital
    corecore