48 research outputs found

    Schroedinger cat-like states by conditional measurements on a beam-splitter

    Full text link
    A scheme for generating Schr\"{o}dinger cat-like states of a single-mode optical field by means of conditional measurement is proposed. Feeding into a beam splitter a squeezed vacuum and counting the photons in one of the output channels, the conditional states in the other output channel exhibit a number of properties that are very similar to those of superpositions of two coherent states with opposite phases. We present analytical and numerical results for the photon-number and quadrature-component distributions of the conditional states and their Wigner and Husimi functions. Further, we discuss the effect of realistic photocounting on the states.Comment: 6 figures(divided in subfigures) using a4.st

    Pregabalin versus gabapentin in partial epilepsy: a meta-analysis of dose-response relationships

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>To compare the efficacy of pregabalin and gabapentin at comparable effective dose levels in patients with refractory partial epilepsy.</p> <p>Methods</p> <p>Eight randomized placebo controlled trials investigating the efficacy of pregabalin (4 studies) and gabapentin (4 studies) over 12 weeks were identified with a systematic literature search. The endpoints of interest were "responder rate" (where response was defined as at least a 50% reduction from baseline in the number of seizures) and "change from baseline in seizure-free days over the last 28 days (SFD)". Results of all trials were analyzed using an indirect comparison approach with placebo as the common comparator. The base-case analysis used the intention-to-treat last observation carried forward method. Two sensitivity analyses were conducted among completer and responder populations.</p> <p>Results</p> <p>The base-case analysis revealed statistically significant differences in response rate in favor of pregabalin 300 mg versus gabapentin 1200 mg (odds ratio, 1.82; 95% confidence interval, 1.02, 3.25) and pregabalin 600 mg versus gabapentin 1800 mg (odds ratio, 2.52; 95% confidence interval, 1.21, 5.27). Both sensitivity analyses supported the findings of the base-case analysis, although statistical significance was not demonstrated. All dose levels of pregabalin (150 mg to 600 mg) were more efficacious than corresponding dosages of gabapentin (900 mg to 2400 mg) in terms of SFD over the last 28 days.</p> <p>Conclusion</p> <p>In patients with refractory partial epilepsy, pregabalin is likely to be more effective than gabapentin at comparable effective doses, based on clinical response and the number of SFD.</p

    >

    No full text

    Parallel single molecule detection with a fully integrated single-photon 2X2 CMOS detector array

    No full text
    We present parallel single molecule detection (SMD) and fluorescence correlation spectroscopy (FCS) experiments with a fully integrated complementary metal oxide semiconductor (CMOS) single-photon 2 X 2 detector array. Multifocal excitation is achieved with a diffractive optical element (DOE). Special emphasis is placed on parallelization of the total system. The performance of the novel single-photon CMOS detector is investigated and compared to a state-of-the-art single-photon detecting module [having an actively quenched avalanche photodiode (APD)] by measurements on free diffusing molecules at different concentrations. Despite the order of magnitude lower detection efficiency of the CMOS detector compared to the state-of-the-art single-photon detecting module, we achieve single molecule sensitivity and reliably determine molecule concentrations. In addition, the CMOS detector performance for the determination of the fraction of slowly diffusing molecules in a primer solution (two-component analysis) is demonstrated. The potential of this new technique for high-throughput confocal-detection-based systems is discussed. (C) 2004 Society of Photo-Optical Instrumentation Engineers
    corecore