Explantation of infected thoracic endovascular aortic repair
Prosthetic graft infection is a rare and serious complication of thoracic endovascular aortic repair associated with high mortality and posing unique challenges for treatment. The prosthetic graft infection is often identified late as patients present with mild nonspecific symptoms. We describe the successful medical management and surgical explantation of an infected thoracic endograft with an aorta-bronchial fistula, using an inline reconstruction with an antibiotic-soaked synthetic graft. In this report, we provide an example of a patient with an infected thoracic endograft and how inline reconstruction combined with appropriate medical management is an acceptable treatment strategy