    First in-human quantitative plaque characterization with ultra-high resolution coronary photon-counting CT angiography

    Full text link
    Purpose: To assess the effect of ultra-high-resolution coronary CT angiography (CCTA) with photon-counting detector (PCD) CT on quantitative coronary plaque characterization. Materials and methods: In this IRB-approved study, 22 plaques of 20 patients (7 women; mean age 77 ± 8 years, mean body mass index 26.1 ± 3.6 kg/m2) undergoing electrocardiography (ECG)-gated ultra-high-resolution CCTA with PCD-CT were included. Images were reconstructed with a smooth (Bv40) and a sharp (Bv64) vascular kernel, with quantum iterative reconstruction (strength level 4), and using a slice thickness of 0.6, 0.4, and 0.2 mm, respectively (field-of-view 200 mm × 200 mm, matrix size 512 × 512 pixels). Reconstructions with the Bv40 kernel and slice thickness of 0.6 mm served as the reference standard. After identification of a plaque in coronary arteries with a vessel diameter ≥2 mm, plaque composition was determined using a dedicated, semi-automated plaque quantification software. Total plaque, calcified, fibrotic, and lipid-rich plaque components were quantified in all datasets. Results: Median plaque volume was highest (23.5 mm3, interquartiles 17.9-34.3 mm3) for reconstructions with the reference standard and lowest for ultra-high-resolution reconstructions with a slice thickness of 0.2 mm and the Bv64 kernel (18.1 mm3, interquartiles 14.1-25.8 mm3, p < 0.001). Reconstructions with the reference standard showed largest calcified (85.1%, interquartiles 76.4-91.1%) and smallest lipid-rich plaque components (0.5%, interquartiles 0.0-1.5%). Smallest calcified plaque components (75.2%, interquartiles 69.9-80.8%) and largest lipid-rich components (6.7%, interquartiles 5.1-8.4%) were found for ultra-high-resolution reconstructions with a slice thickness of 0.2 mm and the Bv64 kernel. At an identical slice thickness, volume of calcified components was always lower, and volume of lipid-rich components was always higher for reconstructions with the Bv64 kernel compared with reconstructions with the Bv40 kernel (all, p < 0.001). Conclusion: This patient study indicates significant differences of ultra-high-resolution scanning with PCD-CT on quantitative coronary plaque characterization. Reduced blooming artifacts may allow improved visualization of fibrotic and lipid-rich plaque components with the ultra-high-resolution mode of PCD-CT. Keywords: coronary artery disease; coronary computed tomographic angiography (CCTA); high risk plaque; photon-counting detector CT (PCD-CT); ultra-high-resolution C

    Photon-Counting Detector CT for Liver Lesion Detection-Optimal Virtual Monoenergetic Energy for Different Simulated Patient Sizes and Radiation Doses

    Get PDF
    OBJECTIVES The aim of this study was to evaluate the optimal energy level of virtual monoenergetic images (VMIs) from photon-counting detector computed tomography (CT) for the detection of liver lesions as a function of phantom size and radiation dose. MATERIALS AND METHODS An anthropomorphic abdominal phantom with liver parenchyma and lesions was imaged on a dual-source photon-counting detector CT at 120 kVp. Five hypoattenuating lesions with a lesion-to-background contrast difference of -30 HU and -45 HU and 3 hyperattenuating lesions with +30 HU and +90 HU were used. The lesion diameter was 5-10 mm. Rings of fat-equivalent material were added to emulate medium- or large-sized patients. The medium size was imaged at a volume CT dose index of 5, 2.5, and 1.25 mGy and the large size at 5 and 2.5 mGy, respectively. Each setup was imaged 10 times. For each setup, VMIs from 40 to 80 keV at 5 keV increments were reconstructed with quantum iterative reconstruction at a strength level of 4 (QIR-4). Lesion detectability was measured as area under the receiver operating curve (AUC) using a channelized Hotelling model observer with 10 dense differences of Gaussian channels. RESULTS Overall, highest detectability was found at 65 and 70 keV for both hypoattenuating and hyperattenuating lesions in the medium and large phantom independent of radiation dose (AUC range, 0.91-1.0 for the medium and 0.94-0.99 for the large phantom, respectively). The lowest detectability was found at 40 keV irrespective of the radiation dose and phantom size (AUC range, 0.78-0.99). A more pronounced reduction in detectability was apparent at 40-50 keV as compared with 65-75 keV when radiation dose was decreased. At equal radiation dose, detection as a function of VMI energy differed stronger for the large size as compared with the medium-sized phantom (12% vs 6%). CONCLUSIONS Detectability of hypoattenuating and hyperattenuating liver lesions differed between VMI energies for different phantom sizes and radiation doses. Virtual monoenergetic images at 65 and 70 keV yielded highest detectability independent of phantom size and radiation dose

    In vitro blood sample assessment: investigating correlation of laboratory hemoglobin and spectral properties of dual-energy CT measurements (ρ/Z)

    Get PDF
    Objectives: Our study comprised a single-center retrospective in vitro correlation between spectral properties, namely ρ/Z values, derived from scanning blood samples using dual-energy computed tomography (DECT) with the corresponding laboratory hemoglobin/hematocrit (Hb/Hct) levels and assessed the potential in anemia-detection. Methods: DECT of 813 patient blood samples from 465 women and 348 men was conducted using a standardized scan protocol. Electron density relative to water (ρ or rho), effective atomic number (Zeff_{eff}), and CT attenuation (Hounsfield unit) were measured. Results: Positive correlation with the Hb/Hct was shown for ρ (r-values 0.37–0.49) and attenuation (r-values 0.59–0.83) while no correlation was observed for Zeff_{eff} (r-values −0.04 to 0.08). Significant differences in attenuation and ρ values were detected for blood samples with and without anemia in both genders (p value < 0.001) with area under the curve ranging from 0.7 to 0.95. Depending on the respective CT parameters, various cutoff values for CT-based anemia detection could be determined. Conclusion: In summary, our study investigated the correlation between DECT measurements and Hb/Hct levels, emphasizing novel aspects of ρ and Zeff_{eff} values. Assuming that quantitative changes in the number of hemoglobin proteins might alter the mean Zeff_{eff} values, the results of our study show that there is no measurable correlation on the atomic level using DECT. We established a positive in vitro correlation between Hb/Hct values and ρ. Nevertheless, attenuation emerged as the most strongly correlated parameter with identifiable cutoff values, highlighting its preference for CT-based anemia detection. Clinical relevance statement: By scanning multiple blood samples with dual-energy CT scans and comparing the measurements with standard laboratory blood tests, we were able to underscore the potential of CT-based anemia detection and its advantages in clinical practice. Key Points: ° Prior in vivo studies have found a correlation between aortic blood pool and measured hemoglobin and hematocrit. ° Hemoglobin and hematocrit correlated with electron density relative to water and attenuation but not Zeff_{eff}. ° Dual-energy CT has the potential for additional clinical benefits, such as CT-based anemia detection

    Dual-energy CT kidney stone characterization-can diagnostic accuracy be achieved at low radiation dose?

    Full text link
    OBJECTIVES To assess the accuracy of low-dose dual-energy computed tomography (DECT) to differentiate uric acid from non-uric acid kidney stones in two generations of dual-source DECT with stone composition analysis as the reference standard. METHODS Patients who received a low-dose unenhanced DECT for the detection or follow-up of urolithiasis and stone extraction with stone composition analysis between January 2020 and January 2022 were retrospectively included. Collected stones were characterized using X-ray diffraction. Size, volume, CT attenuation, and stone characterization were assessed using DECT post-processing software. Characterization as uric acid or non-uric acid stones was compared to stone composition analysis as the reference standard. Sensitivity, specificity, and accuracy of stone classification were computed. Dose length product (DLP) and effective dose served as radiation dose estimates. RESULTS A total of 227 stones in 203 patients were analyzed. Stone composition analysis identified 15 uric acid and 212 non-uric acid stones. Mean size and volume were 4.7 mm × 2.8 mm and 114 mm3^{3}, respectively. CT attenuation of uric acid stones was significantly lower as compared to non-uric acid stones (p < 0.001). Two hundred twenty-five of 227 kidney stones were correctly classified by DECT. Pooled sensitivity, specificity, and accuracy were 1.0 (95%CI: 0.97, 1.00), 0.93 (95%CI: 0.68, 1.00), and 0.99 (95%CI: 0.97, 1.00), respectively. Eighty-two of 84 stones with a diameter of  ≤ 3 mm were correctly classified. Mean DLP was 162 ± 57 mGy*cm and effective dose was 2.43 ± 0.86 mSv. CONCLUSIONS Low-dose dual-source DECT demonstrated high accuracy to discriminate uric acid from non-uric acid stones even at small stone sizes. KEY POINTS • Two hundred twenty-five of 227 stones were correctly classified as uric acid vs. non-uric acid stones by low-dose dual-energy CT with stone composition analysis as the reference standard. • Pooled sensitivity, specificity, and accuracy for stone characterization were 1.0, 0.93, and 0.99, respectively. • Low-dose dual-energy CT for stone characterization was feasible in the majority of small stones  < 3 mm

    Impact of photon-counting-detector-CT derived virtual-monoenergetic-images and iodine-maps on the diagnosis of pleural empyema

    Full text link
    PURPOSE The purpose of this study was to evaluate the impact of virtual monoenergetic image (VMI) energies and iodine maps on the diagnosis of pleural-empyema with photon-counting-detector computed-tomography (PCD-CT). MATERIALS AND METHODS In this IRB-approved retrospective study, consecutive patients with non-infectious pleural effusion or histopathology-proven empyema were included. PCD-CT examinations were performed on a dual-source PCD-CT in the multi-energy (QuantumPlus) mode at 120 kV with weight-adjusted intravenous contrast-agent. VMIs from 40-70 keV obtained in 10 keV intervals and an iodine map was reconstructed for each scan. CT-attenuation was measured in the aorta, the pleura and the peripleural fat (between autochthonous dorsal muscles and dorsal ribs). Contrast-to-noise (CNR) and signal-to-noise (SNR) ratios were calculated. Two blinded radiologists evaluated if empyema was present (yes/no), and rated diagnostic confidence (1 to 4; not confident to fully confident, respectively) with and without using the iodine map. Sensitivity, specificity and diagnostic confidence were estimated. Interobserver agreement was estimated using an unweighted Cohen kappa test. A one-way ANOVA was used to compare variables. Differences in sensitivity and specificity between the different levels of energy were searched using McNemar test. To compare AUC values DeLong test was performed. McNemar test was performed to compare values for sensitivity and specificity. RESULTS Sixty patients (median age, 60 years; 26 women) were included. A strong negative correlation was found between image noise and VMI energies (r = -0.98; P = 0.001) and CNR increased with lower VMI energies (r = -0.98; P = 0.002). Diagnostic accuracy (96%; 95% CI: 82-100) as well as diagnostic confidence (3.4 ± 0.75 [SD]) were highest at 40 keV. Diagnostic accuracy and confidence at higher VMI energies improved with the addition of iodine maps (P ≤0.001). Overall, no difference in CT attenuation of peripleural fat between patients with empyema and those with pleural effusion was found (P = 0.07). CONCLUSION Low VMI energies lead to a higher diagnostic accuracy and diagnostic confidence in the diagnosis of pleural empyema. Iodine maps help in diagnosing empyema only at high VMI energies

    Impact of radiation dose on the detection of interstitial lung changes and image quality in low-dose chest CT - Assessment in multiple dose levels from a single patient scan

    Full text link
    PURPOSE To assess image quality and detectability of interstitial lung changes using multiple radiation doses from the same chest CT scan of patients with suspected interstitial lung disease (ILD). METHOD Retrospective study of consecutive adult patients with suspected ILD receiving unenhanced chest CT as single-energy dual-source acquisition at 100 kVp (Dual-split mode). 67% and 33% of the overall tube current time product were assigned to tube A and B, respectively. 100%-dose was 2.34 ± 0.97 mGy. Five different radiation doses (100%, 67%, 45%, 39%, 33%) were reconstructed from this single acquisition using linear-blending technique. Two blinded radiologists assessed reticulations, ground-glass opacities (GGO) and honeycombing as well as subjective image noise. Percentage agreement (PA) as compared to 100%-dose were calculated. Non-parametric statistical tests were used. RESULTS A total of 228 patients were included (61.2 ± 14.6 years,146 female). PA was highest for honeycombing (>96%) and independent of dose reduction (P > 0.8). PA for reticulations and GGO decreased when reducing the radiation dose from 100% to 67% for both readers (reticulations: 83.3% and 93.9%; GGO: 87.7% and 79.8% for reader 1 and 2, respectively). Additional dose reduction did not significantly change PA for both readers (all P > 0.05). Subjective image noise increased with decreasing radiation dose (Spearman Rho of ρ = 0.34 and ρ = 0.53 for reader 1 and 2, respectively, P < 0.001). CONCLUSIONS Radiation dose reduction had a stronger impact on subtle interstitial lung changes. Detectability decreased with initial dose reduction indicating that a minimum dose is needed to maintain diagnostic accuracy in chest CT for suspected ILD

    Photon-Counting Detector CT Angiography for Endoleak Detection After Endovascular Aortic Repair: Triphasic CT With True Noncontrast Versus Biphasic CT With Virtual Noniodine Imaging

    Full text link
    OBJECTIVES: The aim of this study was to compare image quality and endoleak detection after endovascular abdominal aortic aneurysm repair between a triphasic computed tomography (CT) with true noncontrast (TNC) and a biphasic CT with virtual noniodine (VNI) images on photon-counting detector CT (PCD-CT). MATERIALS AND METHODS: Adult patients after endovascular abdominal aortic aneurysm repair who received a triphasic examination (TNC, arterial, venous phase) on a PCD-CT between August 2021 and July 2022 were retrospectively included. Endoleak detection was evaluated by 2 blinded radiologists on 2 different readout sets (triphasic CT with TNC-arterial-venous vs biphasic CT with VNI-arterial-venous). Virtual noniodine images were reconstructed from the venous phase. The radiologic report with additional confirmation by an expert reader served as reference standard for endoleak presence. Sensitivity, specificity, and interreader agreement (Krippendorf α) were calculated. Image noise was assessed subjectively in patients using a 5-point scale and objectively calculating the noise power spectrum in a phantom. RESULTS: One hundred ten patients (7 women; age, 76 ± 8 years) with 41 endoleaks were included. Endoleak detection was comparable between both readout sets with a sensitivity and specificity of 0.95/0.84 (TNC) versus 0.95/0.86 (VNI) for reader 1 and 0.88/0.98 (TNC) versus 0.88/0.94 (VNI) for reader 2. Interreader agreement for endoleak detection was substantial (TNC: 0.716, VNI: 0.756). Subjective image noise was comparable between TNC and VNI (4; IQR [4, 5] vs 4; IQR [4, 5], P = 0.44). In the phantom, noise power spectrum peak spatial frequency was similar between TNC and VNI (both f peak = 0.16 mm -1 ). Objective image noise was higher in TNC (12.7 HU) as compared with VNI (11.5 HU). CONCLUSIONS: Endoleak detection and image quality were comparable using VNI images in biphasic CT as compared with TNC images in triphasic CT offering the possibility to reduce scan phases and radiation exposure

    Integrated GNSS Attitude Determination and Positioning for Direct Geo-Referencing

    Get PDF
    Direct geo-referencing is an efficient methodology for the fast acquisition of 3D spatial data. It requires the fusion of spatial data acquisition sensors with navigation sensors, such as Global Navigation Satellite System (GNSS) receivers. In this contribution, we consider an integrated GNSS navigation system to provide estimates of the position and attitude (orientation) of a 3D laser scanner. The proposed multi-sensor system (MSS) consists of multiple GNSS antennas rigidly mounted on the frame of a rotating laser scanner and a reference GNSS station with known coordinates. Precise GNSS navigation requires the resolution of the carrier phase ambiguities. The proposed method uses the multivariate constrained integer least-squares (MC-LAMBDA) method for the estimation of rotating frame ambiguities and attitude angles. MC-LAMBDA makes use of the known antenna geometry to strengthen the underlying attitude model and, hence, to enhance the reliability of rotating frame ambiguity resolution and attitude determination. The reliable estimation of rotating frame ambiguities is consequently utilized to enhance the relative positioning of the rotating frame with respect to the reference station. This integrated (array-aided) method improves ambiguity resolution, as well as positioning accuracy between the rotating frame and the reference station. Numerical analyses of GNSS data from a real-data campaign confirm the improved performance of the proposed method over the existing method. In particular, the integrated method yields reliable ambiguity resolution and reduces position standard deviation by a factor of about 0.8, matching the theoretical gain of √3/4 for two antennas on the rotating frame and a single antenna at the reference station

    Quasi-particle re-summation and integral gap equation in thermal field theory

    Full text link
    A new approach to quantum field theory at finite temperature and density in arbitrary space-time dimension D is developed. We focus mainly on relativistic theories, but the approach applies to non-relativistic ones as well. In this quasi-particle re-summation, the free energy takes the free-field form but with the one-particle energy ω(k)\omega (\vec{k}) replaced by \vep (\vec{k}), the latter satisfying a temperature-dependent integral equation with kernel related to a zero temperature form-factor of the trace of stress-energy tensor. For 2D integrable theories the approach reduces to the thermodynamic Bethe ansatz. For relativistic theories, a thermal c-function Cqs(T)C_{\rm qs} (T) is defined for any DD based on the coefficient of the black body radiation formula. Thermodynamical constraints on it's flow are presented, showing that it can violate a ``c-theorem'' even in 2D. At a fixed point CqsC_{\rm qs} is a function of thermal gap parameters which generalizes Roger's dilogarithm to higher dimensions. This points to a strategy for classifying rational theories based on ``polylogarithmic ladders'' in mathematics, and many examples are worked out. An argument suggests that the 3D Ising model has Cqs=7/8C_{\rm qs} = 7/8. (In 3D a free fermion has Cqs=3/4C_{\rm qs} = 3/4.) Other applications are discussed, including the free energy of anyons in 2D and 3D, phase transitions with a chemical potential, and the equation of state for cosmological dark energy.Comment: Version 4: Published versio