4 research outputs found

    Efficacy of Fire Protection Techniques on Impact Resistance of Self-Compacting Concrete

    No full text
    The present research investigates the behaviour of sustainable Self-Compacting Concrete (SCC) when subjected to high temperatures, focusing on workability, post-fire impact resistance, and the effects of fire protection coatings. To develop environmentally friendly SCC mixes, Supplementary Cementitious Materials (SCM) such as Fly Ash (FA), Ground Granulated Blast Furnace Slag (GGBFS), and Expanded Perlite Aggregate (EPA) were used. Fifty-six cubes and ninety-six impact SCC specimens were cast and cured for testing. Fire-resistant Cement Perlite Plaster (CPP) coatings were applied to the protected specimens, a passive protection coating rarely studied. SCC (unprotected and protected) specimens, i.e., protected and unprotected samples, were heated following the ISO standard fire curve. An extensive comparative study has been conducted on utilising different SCMs for developing SCC. Workability behaviour, post-fire impact resistance, and the influence of fire protection coatings on sustainable SCC subjected to high temperatures are the significant parameters examined in the present research, including physical observations and failure patterns. The test results noted that after 30 min of exposure, the unprotected specimen exhibited a significant decrease in failure impact energy, ranging from 80% to 90%. Furthermore, as the heating duration increased, there was a gradual rise in the loss of failure impact energy. However, when considering the protected CPP specimens, it was observed that they effectively mitigated the loss of strength when subjected to elevated temperature. Therefore, the findings of this research may have practical implications for the construction industry and contribute to the development of sustainable and fire-resistant SCC materials

    Influence of Nano Composites on the Impact Resistance of Concrete at Elevated Temperatures

    No full text
    The addition of nanomaterials to concrete efficiently fills the pores of the concrete, thereby improving its hardening characteristics. However, no research is available in the literature that investigated the influence of nano-cement (NC), nano-silica-fume (NS), nano-fly-ash (NF), and nano-metakaolin (NM), which are used as partial replacements for cement, on the impact strength (IS) of concrete at elevated temperatures. This issue is addressed herein. Nanomaterials were used in this study to replace 10%, 20%, and 30% of the cement in four different grades of concrete, starting from M20 to M50, at different temperatures. This nano-blended matrix was exposed to various temperatures ranging from 250 °C to 1000 °C, with an increment of 250 °C. In total, the results of 384 new tests were reported. In addition, morphological changes undergone by the concrete specimens were observed through a scanning electron microscope (SEM). The study revealed that the type of binder, proportion of binder, heating intensity, duration, and cooling type directly influenced the impact strength of concrete when subjected to elevated temperature. In comparison to NC, NF, NS, and NM, the mix with NC possessed superior performance when it was heated at 1000 °C. Prior to being subjected to elevated temperatures, the MK blended concrete mix performed well; however, when subjected to elevated temperatures, the MK blended concrete also experienced severe damage

    Performance of Sustainable Insulated Wall Panels with Geopolymer Concrete

    Get PDF
    The increase in the population creates an increased demand for construction activities with eco-friendly, sustainable, and high-performance materials. Insulated concrete form (ICF) is an emerging technology that satisfies the sustainability demands of the construction sector. ICF is a composite material (a combination of expanded polystyrene (EPS) and geopolymer concrete (GPC)) that enhances the performance of concrete (such as thermal insulation and mechanical properties). To investigate the axial strength performance, five different types of prototypes were created and tested. Type I (without reinforcement): (a) hollow EPS without concrete, (b) alternative cells of EPS filled with concrete, (c) and all the cells of EPS filled with concrete; and Type II (with reinforcement): (d) alternative cells of EPS filled with concrete; (e) and all the cells of EPS filled with concrete. Amongst all the five prototypes, two grades of GPC were employed. M15 and M20 grades are used to examine the effectiveness in terms of cost. For comparing the test results, a reference masonry unit was constructed with conventional clay bricks. The main aim of the investigation is to examine the physical and mechanical performance of sandwich-type ICFs. The presence of polystyrene in ICF changes the failure pattern from brittle to ductile. The result from the study reveals that the Type II prototype, i.e., the specimen with all the cells of EPS filled with concrete and reinforcement, possesses a maximum load-carrying capacity greater than the reference masonry unit. Therefore, the proposed ICF is recommended to replace the conventional load-bearing system and non-load-bearing walls

    Influence of Heating–Cooling Regime on the Engineering Properties of Structural Concrete Subjected to Elevated Temperature

    No full text
    Structural concrete has become a highly preferable building material in the construction industry due to its versatile characteristics, such as workability, strength, and durability. When concrete structures are exposed to fire, the mechanical properties of concrete degrade significantly. The research on the residual mechanical properties of concrete after exposure is necessary, particularly for the repair and rehabilitation of concrete elements and for the stability of the infrastructure. Factors, such as the grade of concrete, the effect of temperature exposure, and rapid water cooling, affect the residual strength characteristics of concrete. Considering these factors, the present investigation evaluates the mechanical properties of concrete using different grades, such as those ranging from 20 to 50 MPa, with an increment of 10 MPa. The specimens were exposed to different durations of fire from 15 to 240 min, following the standard rate of heating. A loss of strength was observed after fire exposure for all the grades of concrete. The rate of reduction in tensile and flexural strengths of the concrete was greater than that of compressive strength. The experimental results also showed that the strength reduction is greater for M50 than M20 concrete concerning the duration of heating. A microstructure evaluation confirmed the extent of damage to concrete under varied temperature conditions