5 research outputs found

    Effects of Implantable Collamer Lens V4c Placement on Iridocorneal Angle Measurements by Fourier-Domain Optical Coherence Tomography

    No full text
    Purpose To assess by Fourier-domain optical coherence tomography (FDOCT) changes produced in iridocorneal angle measurements in patients undergoing Visian Implantable Collamer Lens (ICL) V4c (STAAR Surgical AG) placement. Design Prospective interventional case series. Methods In 50 eyes of 25 myopic subjects consecutively scheduled for ICL implant, FDOCT (RTVue; Optovue Inc) iridocorneal angle measurements were made before and 1 and 3 months after surgery. Trabecular-iris angle (TIA) and angle opening distance 500 μm anterior to the scleral spur (AOD500) were compared among the quadrants nasal, temporal, and inferior, and correlations with ocular variables including lens vault were examined. Results Preoperative TIA was 48.7 ± 8.7, 48.2 ± 8.7, and 48.7 ± 9.3 degrees for the nasal, temporal, and inferior quadrants, with no differences (P= 1.000). Following ICL implant, corresponding values fell to 31.2 ± 11.5, 30.0 ± 10.7, and 29.7 ± 8.1 degrees at 1 month postsurgery, indicating angle narrowing of 34%-42%, and to 30.6 ± 12.3, 30.1 ± 11.9, and 29.8 ± 12.3 degrees, respectively, at 3 months postsurgery. Angle measurements failed to vary between 1 month and 3 months postsurgery (P= .481). In 8 eyes, iridotrabecular contact attributable to surgery was observed. One month after surgery, vault measurements correlated with TIA (R = -.309;P= .048). Six variables were identified as predictors of TIA at 1 month postsurgery (R2= .907). Conclusions Although considerable angle narrowing was detected 1 month after ICL V4c implant, this narrowing remained stable at 3 months postsurgery. Factors predictive of TIA could serve to identify suitable candidates for ICL placement

    Computational simulation of aqueous humour dynamics in the presence of a posterior-chamber versus iris-fixed phakic intraocular lens.

    No full text
    PURPOSE:To compare aqueous humour (AH) dynamics in the presence of a precrystalline (Implantable Collamer Lens®; ICL) or iris-fixed (Artiflex®) phakic intraocular lens (PIOL). METHODS:By computational fluid dynamics simulation, AH flow was modelled through a peripheral iridotomy (PI) or central lens hole (both 360 μm) in the presence of an Artiflex or ICL lens, respectively. The impacts of AH flow were then determined in terms of wall shear stress (WSS) produced on the endothelium or crystalline lens. Effects were also modelled for different scenarios of pupil diameter (PD 3.5 or 5.5 mm), ICL vault (100, 350, 800 μm) and number of Artiflex iridotomies (1 or 2) and location (12 or 6 o'clock). RESULTS:For a PD of 3.5 mm, AH volumes flowing from the posterior to the anterior chamber were 37.6% of total flow through the lens hole (ICL) and 84.2% through PI (Artiflex). For an enlarged PD (5.5 mm), corresponding values were 10.3% and 81.9% respectively, so PI constitutes a very efficient way of evacuating AH. Central endothelial WSS in Pa was lower for the large vault ICL and the Artiflex (1-03 and 1.1-03 respectively) compared to the PIOL-free eye (1.6-03). Crystalline lens WSS was highest for the lowest vault ICL (1-04). CONCLUSIONS:AH flow varied according to the presence of a precrystalline or iris-fixed intraocular lens. Endothelial WSS was lower for an implanted ICL with large vault and Artiflex than in the PIOL-free eye, while highest crystalline WSS was recorded for the lowest vault ICL

    Computational study of aqueous humor dynamics assessing the vault and the pupil diameter in two posterior-chamber phakic lenses

    Get PDF
    Purpose: To compare the behavior of aqueous humor (AH) and analyze flow differences by comparing the volume and velocity of the flow after two different models of implantable collamer lens (ICL) placement. Methods: Computational fluid dynamics with numerical simulation using Ansys Fluent software was performed to compare the AH flow through a peripheral iridotomy (PI), which is typically performed after implantation of a V4b lens to the central hole of a V4c lens. The volume and flow rate in 24 scenarios were compared according to the type of lens, pupil diameter (PD) (3.5 or 5.5 mm), the vault (100, 350, and 800 μm) and the PI (single or double, 180 or 360 μm). Results: With a standard vault (350 μm) and a PD of 3.5 mm, the volume of AH that flows from the posterior to the anterior chamber through the PI (V4b lens: 73.4% in 360 μm and 17.3% in 180 μm) and for the central hole (V4c lens: 75.7%) is larger than in the case of a PD of 5.5 mm (13.9%, 0.91%, and 15.3% respectively). When the vault is low (100; PD 3.5 mm), the volume of AH that reaches the central hole of the V4c lens is diminished (52.0%), being 5.1% if the pupil is enlarged. Conclusions: AH flow varies depending on the type of ICL implanted, whether it is implanted with an iridotomy or a central hole on the lens, the PD, and the vault

    Promoción turística sostenible de la reserva de la biosfera Tajo-Tejo Internacional

    No full text
    Convocatoria proyectos de innovación de Extremadura 2020/2021Se describe un proyecto llevado acabo por varios centros educativos ubicados en la zona de la Reserva de la Biosfera Tajo-Tejo Internacional (RBTTI) que pretendía contribuir a la transformación sostenible del entorno mediante su conocimiento y promoción, implementando las competencias digital, social y ciudadana y la cultura emprendedora mediante metodologías activas como el aprendizaje servicio. Entre los objetivos principales del proyecto destacan: dar a conocer las implicaciones de la RBTTI; diseñar una campaña de promoción de la RBTTI mediante trípticos y vídeos promocionales; conocer la Reserva a través de las principales vías pecuarias y caminos que comunican los pueblos; descubrir los principales elementos socioculturales, históricos y tradicionales de la Reserva; valorar la importancia del territorio para conservar la biodiversidad: paisajes, ecosistemas, fauna y flora representativa; relacionar la trashumancia y las vías pecuarias como rasgos identificativos de la Reserva, vinculándolo con la historia y rasgos culturales de los pueblos y valorar el emprendimiento y la iniciativa personal, el asosiacionismo y creación de redes de cooperación en y entre pueblos como motor de desarrolloExtremaduraES
    corecore