31 research outputs found
Quantitative Evaluation of Pulmonary Emphysema Using Magnetic Resonance Imaging and x-ray Computed Tomography
Chronic obstructive pulmonary disease (COPD) is a leading cause of morbidity and mortality affecting at least 600 million people worldwide. The most widely used clinical measurements of lung function such as spirometry and plethysmography are generally accepted for diagnosis and monitoring of the disease. However, these tests provide only global measures of lung function and they are insensitive to early disease changes. Imaging tools that are currently available have the potential to provide regional information about lung structure and function but at present are mainly used for qualitative assessment of disease and disease progression. In this thesis, we focused on the application of quantitative measurements of lung structure derived from 1H magnetic resonance imaging (MRI) and high resolution computed tomography (CT) in subjects diagnosed with COPD by a physician. Our results showed that significant and moderately strong relationship exists between 1H signal intensity (SI) and 3He apparent diffusion coefficient (ADC), as well as between 1H SI and CT measurements of emphysema. This suggests that these imaging methods may be quantifying the same tissue changes in COPD, and that pulmonary 1H SI may be used effectively to monitor emphysema as a complement to CT and noble gas MRI. Additionally, our results showed that objective multi-threshold analysis of CT images for emphysema scoring that takes into account the frequency distribution of each Hounsfield unit (HU) threshold was effective in correctly classifying the patient into COPD and healthy subgroups. Finally, we found a significant correlation between whole lung average subjective and objective emphysema scores with high inter-observer agreement. It is concluded that 1H MRI and high resolution CT can be used to quantitatively evaluate lung tissue alterations in COPD subjects
Chest MRI in children: Why bother?
In this issue of Respirology, Montella and colleagues ask this question: How does highâfield chest MRI compare with CT of children with nonâcystic fibrosis (CF) lung disease? In an important extension of the first description of this study where they compared MRI and CT with pulmonary function measurements, the authors evaluated how widelyâused chest CT and almost neverâutilized lung MRI compare for diagnostic imaging of chronic lung disease. Here they show that highâfield (3Tesla as compared with the 1.5Tesla clinical standard) thoracic MRI has high reliability and goodâtoâexcellent agreement with CT, definitively answering the important question at hand; their results support more widespread and routine use of MRI in longitudinal monitoring of chronic lung disease, especially in children as well as further optimization and improvement of lung MRI methods. Importantly, nonâCF lung disease accounts for the majority of paediatric pulmonary abnormalities and the increasing prevalence and economic burden related to chronic respiratory disease should motivate the research and development of novel MRI methods for serial and longitudinal imaging
On the role of abnormal DL(CO) in ex-smokers without airflow limitation: symptoms, exercise capacity and hyperpolarised helium-3 MRI
BACKGROUND: The functional effects of abnormal diffusing capacity for carbon monoxide (DLCO) in ex-smokers without chronic obstructive pulmonary disease (COPD) are not well understood.
OBJECTIVE: We aimed to evaluate and compare well established clinical, physiological and emerging imaging measurements in ex-smokers with normal spirometry and abnormal DLCO with a group of ex-smokers with normal spirometry and DLCO and ex-smokers with Global Initiative for Chronic Obstructive Lung Disease (GOLD) stage I COPD.
METHODS: We enrolled 38 ex-smokers and 15 subjects with stage I COPD who underwent spirometry, plethysmography, St George\u27s Respiratory Questionnaire (SGRQ), 6 min Walk Test (6MWT), x-ray CT and hyperpolarised helium-3 ((3)He) MRI. The 6MWT distance (6MWD), SGRQ scores, (3)He MRI apparent diffusion coefficients (ADC) and CT attenuation values below -950 HU (RA950) were evaluated.
RESULTS: Of 38 ex-smokers without COPD, 19 subjects had abnormal DLCO with significantly worse ADC (p=0.01), 6MWD (p=0.008) and SGRQ (p=0.01) but not RA950 (p=0.53) compared with 19 ex-smokers with normal DLCO. Stage I COPD subjects showed significantly worse ADC (p=0.02), RA950 (p=0.0008) and 6MWD (p=0.005), but not SGRQ (p=0.59) compared with subjects with abnormal DLCO. There was a significant correlation for (3)He ADC with SGRQ (r=0.34, p=0.02) and 6MWD (r=-0.51, p=0.0002).
CONCLUSIONS: In ex-smokers with normal spirometry and CT but abnormal DLCO, there were significantly worse symptoms, 6MWD and (3)He ADC compared with ex-smokers with normal DLCO, providing evidence of the impact of mild or early stage emphysema and a better understanding of abnormal DLCO and hyperpolarised (3)He MRI in ex-smokers without COPD
Hyperpolarized 3He and 129Xe magnetic resonance imaging apparent diffusion coefficients: physiological relevance in older never- and ex-smokers
Noble gas pulmonary magnetic resonance imaging (MRI) is transitioning away from (3)He to (129)Xe gas, but the physiological/clinical relevance of (129)Xe apparent diffusion coefficient (ADC) parenchyma measurements is not well understood. Therefore, our objective was to generate (129)Xe MRI ADC for comparison with (3)He ADC and with well-established measurements of alveolar structure and function in older never-smokers and ex-smokers with chronic obstructive pulmonary disease (COPD). In four never-smokers and 10 COPD ex-smokers, (3)He (b = 1.6 sec/cm(2)) and (129)Xe (b = 12, 20, and 30 sec/cm(2)) ADC, computed tomography (CT) density-threshold measurements, and the diffusing capacity for carbon monoxide (DLCO) were measured. To understand regional differences, the anterior-posterior (APG) and superior-inferior (âSI) ADC differences were evaluated. Compared to never-smokers, COPD ex-smokers showed greater (3)He ADC (P = 0.006), (129)Xe ADCb12 (P = 0.006), and ADCb20 (P = 0.006), but not for ADCb30 (P \u3e 0.05). Never-smokers and COPD ex-smokers had significantly different APG for (3)He ADC (P = 0.02), (129)Xe ADCb12 (P = 0.006), and ADCb20 (P = 0.01), but not for ADCb30 (P \u3e 0.05). âSI for never- and ex-smokers was significantly different for (3)He ADC (P = 0.046), but not for (129)Xe ADC (P \u3e 0.05). There were strong correlations for DLCO with (3)He ADC and (129)Xe ADCb12 (both r = -0.95, P \u3c 0.05); in a multivariate model (129)Xe ADCb12 was the only significant predictor of DLCO (P = 0.049). For COPD ex-smokers, CT relative are
Revisiting fetal dose during radiation therapy: evaluating treatment techniques and a custom shield [JACMP, 17(5), 2016]
Peer Reviewedhttps://deepblue.lib.umich.edu/bitstream/2027.42/139980/1/acm212191_am.pdfhttps://deepblue.lib.umich.edu/bitstream/2027.42/139980/2/acm212191.pd
Hyperpolarized 3He and 129Xe MR imaging in healthy volunteers and patients with chronic obstructive pulmonary disease
PURPOSE: To quantitatively compare hyperpolarized helium 3 (3He) and xenon 129 (129Xe) magnetic resonance (MR) images obtained within 5 minutes in healthy volunteers and patients with chronic obstructive pulmonary disease (COPD) and to evaluate the correlations between 3He and 129Xe MR imaging measurements and those from spirometry and plethysmography.
MATERIALS AND METHODS: This study was approved by an ethics board and compliant with HIPAA. Written informed consent was obtained from all subjects. Eight healthy volunteers and 10 patients with COPD underwent MR imaging, spirometry, and plethysmography. Ventilation defect percentages (VDPs) at 3He and 129Xe imaging were obtained by using semiautomated segmentation. Apparent diffusion coefficients (ADCs) were calculated from 3He (b=1.6 sec/cm2) and 129Xe (b=12 sec/cm2) diffusion-weighted images. VDPs at hyperpolarized 3He and 129Xe imaging were compared with a two-tailed Wilcoxon signed rank test and analysis of variance; Pearson correlation coefficients were used to evaluate the relationships among measurements.
RESULTS: 129Xe VDP was significantly greater than 3He VDP for patients with COPD (P
CONCLUSION: In patients with COPD, the VDP obtained with hyperpolarized 29Xe MR imaging was significantly greater than that with 3He MR imaging, suggesting incomplete or delayed filling of lung regions that may be related to the different properties of 129Xe gas and physiologic and/or anatomic abnormalities in COPD
Revisiting fetal dose during radiation therapy: evaluating treatment techniques and a custom shield
Peer Reviewedhttp://deepblue.lib.umich.edu/bitstream/2027.42/135233/1/acm20001i.pd