45 research outputs found

    Prosthesis-patient mismatch after aortic valve replacement in the PARTNER 2 trial and registry

    Get PDF
    Objectives This study aimed to compare incidence and impact of measured prosthesis-patient mismatch (PPMM) versus predicted PPM (PPMP) after surgical aortic valve replacement (SAVR) and transcatheter aortic valve replacement (TAVR). Background TAVR studies have used measured effective orifice area indexed (EOAi) to body surface area (BSA) to define PPM, but most SAVR series have used predicted EOAi. This difference may contribute to discrepancies in incidence and outcomes of PPM between series. Methods The study analyzed SAVR patients from the PARTNER (Placement of Aortic Transcatheter Valves) 2A trial and TAVR patients from the PARTNER 2 SAPIEN 3 Intermediate Risk registry. PPM was classified as moderate if EOAi ≤0.85 cm2/m2 (≤0.70 if obese: body mass index ≥30 kg/m2) and severe if EOAi ≤0.65 cm2/m2 (≤0.55 if obese). PPMM was determined by the core lab–measured EOAi on 30-day echocardiogram. PPMP was determined by 2 methods: 1) using normal EOA reference values previously reported for each valve model and size (PPMP1; n = 929 SAVR, 1,069 TAVR) indexed to BSA; and 2) using normal reference EOA predicted from aortic annulus size measured by computed tomography (PPMP2; n = 864 TAVR only) indexed to BSA. Primary endpoint was the composite of 5-year all-cause death and rehospitalization. Results The incidence of moderate and severe PPMP was much lower than PPMM in both SAVR (PPMP1: 28.4% and 1.2% vs. PPMM: 31.0% and 23.6%) and TAVR (PPMP1: 21.0% and 0.1% and PPMP2: 17.0% and 0% vs. PPMM: 27.9% and 5.7%). The incidence of severe PPMM and severe PPMP1 was lower in TAVR versus SAVR (P < 0.001). The presence of PPM by any method was associated with higher transprosthetic gradient. Severe PPMP1 was independently associated with events in SAVR after adjustment for sex and Society of Thoracic Surgeons score (hazard ratio: 3.18;95% CI: 1.69-5.96; P < 0.001), whereas no association was observed between PPM by any method and outcomes in TAVR. Conclusions EOAi measured by echocardiography results in a higher incidence of PPM following SAVR or TAVR than PPM based on predicted EOAi. Severe PPMP is rare (<1.5%), but is associated with increased all-cause death and rehospitalization after SAVR, whereas it is absent following TAVR

    Tricuspid Valve Academic Research Consortium Definitions for Tricuspid Regurgitation and Trial Endpoints.

    Get PDF
    Interest in the pathophysiology, etiology, management, and outcomes of patients with tricuspid regurgitation (TR) has grown in the wake of multiple natural history studies showing progressively worse outcomes associated with increasing TR severity, even after adjusting for multiple comorbidities. Historically, isolated tricuspid valve surgery has been associated with high in-hospital mortality rates, leading to the development of transcatheter treatment options. The aim of this first Tricuspid Valve Academic Research Consortium document is to standardize definitions of disease etiology and severity, as well as endpoints for trials that aim to address the gaps in our knowledge related to identification and management of patients with TR. Standardizing endpoints for trials should provide consistency and enable meaningful comparisons between clinical trials. A second Tricuspid Valve Academic Research Consortium document will focus on further defining trial endpoints and will discuss trial design options

    Tricuspid Valve Academic Research Consortium Definitions for Tricuspid Regurgitation and Trial Endpoints.

    Get PDF
    Interest in the pathophysiology, etiology, management, and outcomes of patients with tricuspid regurgitation (TR) has grown in the wake of multiple natural history studies showing progressively worse outcomes associated with increasing TR severity, even after adjusting for multiple comorbidities. Historically, isolated tricuspid valve surgery has been associated with high in-hospital mortality rates, leading to the development of transcatheter treatment options. The aim of this first Tricuspid Valve Academic Research Consortium document is to standardize definitions of disease etiology and severity, as well as endpoints for trials that aim to address the gaps in our knowledge related to identification and management of patients with TR. Standardizing endpoints for trials should provide consistency and enable meaningful comparisons between clinical trials. A second Tricuspid Valve Academic Research Consortium document will focus on further defining trial endpoints and will discuss trial design options

    Transcatheter or surgical aortic-valve replacement in intermediate-risk patients

    Get PDF
    BACKGROUND: Previous trials have shown that among high-risk patients with aortic stenosis, survival rates are similar with transcatheter aortic-valve replacement (TAVR) and surgical aorticvalve replacement. We evaluated the two procedures in a randomized trial involving intermediate-risk patients. METHODS: We randomly assigned 2032 intermediate-risk patients with severe aortic stenosis, at 57 centers, to undergo either TAVR or surgical replacement. The primary end point was death from any cause or disabling stroke at 2 years. The primary hypothesis was that TAVR would not be inferior to surgical replacement. Before randomization, patients were entered into one of two cohorts on the basis of clinical and imaging findings; 76.3% of the patients were included in the transfemoral-access cohort and 23.7% in the transthoracic-access cohort. RESULTS: The rate of death from any cause or disabling stroke was similar in the TAVR group and the surgery group (P=0.001 for noninferiority). At 2 years, the Kaplan–Meier event rates were 19.3% in the TAVR group and 21.1% in the surgery group (hazard ratio in the TAVR group, 0.89; 95% confidence interval [CI], 0.73 to 1.09; P=0.25). In the transfemoralaccess cohort, TAVR resulted in a lower rate of death or disabling stroke than surgery (hazard ratio, 0.79; 95% CI, 0.62 to 1.00; P=0.05), whereas in the transthoracic-access cohort, outcomes were similar in the two groups. TAVR resulted in larger aortic-valve areas than did surgery and also resulted in lower rates of acute kidney injury, severe bleeding, and new-onset atrial fibrillation; surgery resulted in fewer major vascular complications and less paravalvular aortic regurgitation. CONCLUSIONS: In intermediate-risk patients, TAVR was similar to surgical aortic-valve replacement with respect to the primary end point of death or disabling stroke. (Funded by Edwards Lifesciences; PARTNER 2 ClinicalTrials.gov number, NCT01314313

    Transcatheter Aortic-Valve Replacement with a Balloon-Expandable Valve in Low-Risk Patients.

    Get PDF
    BACKGROUND: Among patients with aortic stenosis who are at intermediate or high risk for death with surgery, major outcomes are similar with transcatheter aortic-valve replacement (TAVR) and surgical aortic-valve replacement. There is insufficient evidence regarding the comparison of the two procedures in patients who are at low risk. METHODS: We randomly assigned patients with severe aortic stenosis and low surgical risk to undergo either TAVR with transfemoral placement of a balloon-expandable valve or surgery. The primary end point was a composite of death, stroke, or rehospitalization at 1 year. Both noninferiority testing (with a prespecified margin of 6 percentage points) and superiority testing were performed in the as-treated population. RESULTS: At 71 centers, 1000 patients underwent randomization. The mean age of the patients was 73 years, and the mean Society of Thoracic Surgeons risk score was 1.9% (with scores ranging from 0 to 100% and higher scores indicating a greater risk of death within 30 days after the procedure). The Kaplan-Meier estimate of the rate of the primary composite end point at 1 year was significantly lower in the TAVR group than in the surgery group (8.5% vs. 15.1%; absolute difference, -6.6 percentage points; 95% confidence interval [CI], -10.8 to -2.5; P<0.001 for noninferiority; hazard ratio, 0.54; 95% CI, 0.37 to 0.79; P = 0.001 for superiority). At 30 days, TAVR resulted in a lower rate of stroke than surgery (P = 0.02) and in lower rates of death or stroke (P = 0.01) and new-onset atrial fibrillation (P<0.001). TAVR also resulted in a shorter index hospitalization than surgery (P<0.001) and in a lower risk of a poor treatment outcome (death or a low Kansas City Cardiomyopathy Questionnaire score) at 30 days (P<0.001). There were no significant between-group differences in major vascular complications, new permanent pacemaker insertions, or moderate or severe paravalvular regurgitation. CONCLUSIONS: Among patients with severe aortic stenosis who were at low surgical risk, the rate of the composite of death, stroke, or rehospitalization at 1 year was significantly lower with TAVR than with surgery. (Funded by Edwards Lifesciences; PARTNER 3 ClinicalTrials.gov number, NCT02675114.)

    Association of natriuretic peptide levels after transcatheter aortic valve replacement with subsequent clinical outcomes

    No full text
    Importance Among those with aortic stenosis, natriuretic peptide levels can provide risk stratification, predict symptom onset, and aid decisions regarding the timing of valve replacement. Less is known about the prognostic significance and potential clinical utility of natriuretic peptide levels measured after valve replacement. Objective : To determine the associations of elevated B-type natriuretic peptide (BNP) levels after transcatheter aortic valve replacement (TAVR) and change in BNP levels between follow-up time points with risk of subsequent clinical outcomes. Design, Setting, and Participants : In this cohort study, patients with severe symptomatic aortic stenosis at intermediate, high, or prohibitive surgical risk for aortic valve replacement who underwent TAVR from the PARTNER IIA cohort, PARTNER IIB cohort, SAPIEN 3 intermediate-risk registry, and SAPIEN 3 high-risk registry were included. B-type natriuretic peptide levels were obtained at baseline and discharge as well as 30 days and 1 year after TAVR. For each measurement, a BNP ratio was calculated using measured BNP level divided by the upper limit of normal for the assay used. Outcomes were evaluated in landmark analyses out to 2 years. Data were collected from April 2011 to January 2019. Main Outcomes and Measures : All-cause death, cardiovascular death, rehospitalization, and the combined end point of cardiovascular death or rehospitalization. Results : Among 3391 included patients, 1969 (58.1%) were male, and the mean (SD) age was 82 (7.5) years. Most patients had a BNP ratio greater than 1 at each follow-up time point, including 2820 of 3256 (86.6%) at baseline, 2652 of 2995 (88.5%) at discharge, 1779 of 2209 (80.5%) at 30 days, and 1799 of 2391 (75.2%) at 1 year. After adjustment, every 1-point increase in BNP ratio at 30 days (approximately equivalent to an increase of 100 pg/mL in BNP) was associated with an increased hazard of all-cause death (adjusted hazard ratio [aHR], 1.11; 95% CI, 1.07-1.15), cardiovascular death (aHR, 1.16; 95% CI, 1.11-1.21), and rehospitalization (aHR, 1.08; 95% CI, 1.03-1.14) between 30 days and 2 years. Among those with a BNP ratio of 2 or more at discharge, after adjustment, every 1-point decrease in BNP ratio between discharge and 30 days was associated with a decreased hazard of all-cause death (aHR, 0.92; 95% CI, 0.88-0.96) between 30 days and 2 years. Conclusions and Relevance : Elevated BNP levels after TAVR was independently associated with increased subsequent mortality and rehospitalizations. Further studies to determine how best to mitigate this risk are warranted

    Impact of right ventricle-pulmonary artery coupling on clinical outcomes in the PARTNER 3 trial

    No full text
    BACKGROUND Physiologic right ventricle–pulmonary artery (RV-PA) coupling may be impaired in patients with aortic stenosis (AS). OBJECTIVES This study aimed to assess the incidence and prognostic significance of impaired RV-PA coupling in low-risk patients with symptomatic severe AS undergoing transcatheter aortic valve replacement or surgical aortic valve replacement. METHODS RV-PA coupling was measured by transthoracic echocardiography as the ratio of tricuspid annular plane systolic excursion (TAPSE) to pulmonary artery systolic pressure (PASP) in patients in the PARTNER (Placement of Aortic Transcatheter Valve) 3 trial. The primary endpoint was the composite of all-cause mortality, stroke, and rehospitalization at the 2-year follow-up. RESULTS Among 570 low-risk patients included in the analysis, RV-PA uncoupling was defined by a TAPSE/PASP ratio ≤ 0.55 mm/mm Hg. At baseline, 222 of 570 (38.9%) patients had RV-PA uncoupling. At 2 years, patients with baseline RV-PA uncoupling had an increased incidence of the primary endpoint (19.1% vs 9.9%, P = 0.002), all-cause mortality (5.9% vs 0.6%, P < 0.001), cardiovascular mortality (4.1% vs 0.6%, P = 0.003), and rehospitalization (13.5% vs 7.3%, P = 0.018). On multivariable analysis, baseline RV-PA uncoupling remained an independent predictor of the primary endpoint at 2 years (HR: 1.92; 95% CI: 1.04-3.57; P = 0.038). CONCLUSIONS In patients with symptomatic severe AS at low surgical risk undergoing transcatheter aortic valve replacement or surgical aortic valve replacement, baseline RV-PA uncoupling defined by TAPSE/PASP ≤ 0.55 mm Hg was associated with adverse clinical outcomes at 2 years, including all-cause mortality, cardiovascular mortality, and rehospitalization

    Low and elevated- B-type natriuretic peptide levels are associated with increased mortality in patients with preserved ejection fraction undergoing transcatheter aortic valve replacement: an analysis of the PARTNER II trial and registry

    No full text
    Aims : B-type natriuretic peptide (BNP) is a cardiac neurohormone that is secreted in response to ventricular volume expansion and pressure overload. There are conflicting data regarding the association between BNP levels and outcomes after transcatheter aortic valve replacement (TAVR). We therefore sought to assess the association between baseline BNP and adverse outcomes in patients with symptomatic, severe aortic stenosis (AS), and left ventricular ejection fraction (LVEF) >_50%, undergoing TAVR in the PARTNER 2 Trial and Registry. Methods and results : A total of 1782 patients were included in the analysis, and BNP was evaluated both as a continuous log- transformed value and by a priori categories: low (_50 and _100 and _400 pg/mL). Clinical outcomes from discharge to 2 years were compared between patients according to their baseline BNP level, using Kaplan–Meier event rates and multivariable Cox proportional hazards regression models. After adjustment, spline curves revealed a non-linear association be- tween log-transformed BNP and all-cause and cardiovascular mortality in which both the lowest and highest values were associated with increased mortality. Two-year all-cause mortality rates for those with low (n = 86), normal (n = 202), moderately elevated (n = 885), and markedly elevated (n = 609) baseline BNP were 20.0%, 9.8%, 17.7%, and 26.1%, respectively. In adjusted models, compared to a normal baseline BNP, low [adjusted hazard ratio (HR) 2.6, 95% confidence interval (CI) 1.3–5.0, P-value 0.005], moderately elevated (adjusted HR 1.6, 95% CI 1.0–2.6, P-value 0.06), and markedly elevated (adjusted HR 2.1, 95% CI 1.3–3.5, P-value 0.003) BNP were associated with increased all-cause mortality, driven by cardiovascular mortality. Conclusions : In a large cohort of patients with severe symptomatic AS and preserved LVEF undergoing TAVR, all-cause and cardiovascular mortality rates at 2 years were higher in patients with low and markedly elevated BNP levels
    corecore