    An open-source development based on photogrammetry for a real-time IORT treatment planning system

    Get PDF
    Purpose This study presents a treatment planning system for intraoperative low-energy photon radiotherapy based on photogrammetry from real images of the surgical site taken in the operating room. Material and methods The study population comprised 15 patients with soft-tissue sarcoma. The system obtains the images of the area to be irradiated with a smartphone or tablet, so that the absorbed doses in the tissue can be calculated from the reconstruction without the need for computed tomography. The system was commissioned using 3D printing of the reconstructions of the tumor beds. The absorbed doses at various points were verified using radiochromic films that were suitably calibrated for the corresponding energy and beam quality. Results The average reconstruction time of the 3D model from the video sequence in the 15 patients was 229,6±7,0 s. The entire procedure, including video capture, reconstruction, planning, and dose calculation was 520,6±39,9 s. Absorbed doses were measured on the 3D printed model with radiochromic film, the differences between these measurements and those calculated by the treatment planning system were 1.4% at the applicator surface, 2.6% at 1 cm, 3.9% at 2 cm and 6.2% at 3 cm. Conclusions The study shows a photogrammetry-based low-energy photon IORT planning system, capable of obtaining real-time images inside the operating room, immediately after removal of the tumor and immediately before irradiation. The system was commissioned with radiochromic films measurements in 3D-printed model

    End-To-End procedure for IORT in brain metastases and film dosimetry

    Get PDF
    Purpose: The study is intended to perform an end-to-end test of the entire intraoperative process using cadaver heads. A simulation of tumor removal was performed, followed by irradiation of the bed and measurement of absorbed doses with radiochromic films. Materials and Methods: Low-energy X-ray intraoperative radiotherapy (IORT) was used for irradiation. A computed tomography study was performed at each site and the absorbed doses calculated by the treatment planning system, as well as absorbed doses with radiochromic films, were studied. Results: The absorbed doses in the organs at risk (OAR) were evaluated in each case, obtaining maximum doses within the tolerance limits. The absorbed doses in the target were verified and the deviations were <1%. Conclusions: These tests demonstrated that this comprehensive procedure is a reproducible quality assurance tool which allows continuous assessment of the dosimetric and geometric accuracy of clinical brain IORT treatments. Furthermore, the absorbed doses measured in both target and OAR are optimal for these treatments
    corecore