6 research outputs found

    Clinical outcomes of the Lotus Valve in patients with bicuspid aortic valve stenosis: An analysis from the RESPOND study

    Get PDF
    Aims: Patients with bicuspid valves represent a challenging anatomical subgroup for transcatheter aortic valve implantation (TAVI). This analysis evaluated the clinical outcomes of the fully repositionable and retrievable Lotus Valve System in patients with bicuspid aortic valves enrolled in the RESPOND post-market registry. Methods and Results: The prospective, open-label RESPOND study enrolled 1,014 patients at 41 centers in Europe, New Zealand, and Latin America, 31 (3.1%) of whom had bicuspid aortic valves. The mean age in the bicuspid patient cohort was 76.4 years, 64.5% were male, and the baseline STS score was 6.0 ± 10.2. Procedural success was 100%, with no cases of malpositioning, valve migration, embolization, or valve-in-valve. Repositioning was attempted in 10 cases (32.3%). There was one death (3.2%) and one stroke (3.2%) at 30-day follow-up. Mean AV gradient was reduced from 48.7 ± 17.0 mmHg at baseline to 11.8 ± 5.1 mmHg at hospital discharge (P < 0.001); mean effective orifice area (EOA

    Use of a Repositionable and Fully Retrievable Aortic Valve in Routine Clinical Practice: The RESPOND Study and RESPOND Extension Cohort

    Get PDF
    Objectives: The authors sought to evaluate 1-year clinical outcomes with the Lotus valve (Boston Scientific, Marlborough, Massachusetts) in a large international, multicenter prospective registry including patients eligible for transcatheter aortic valve replacement (TAVR) based on heart team consensus. Background: TAVR is a safe and effective treatment for severe aortic valve stenosis; however, limited data are available on TAVR with the repositionable and fully retrievable Lotus valve in unrestricted contemporary clinical practice. Methods: The RESPOND (Repositionable Lotus Valve System—Post-Market Evaluation of Real World Clinical Outcomes) study enrolled 1,014 patients; 996 patients were implanted with the Lotus valve (mean age 80.8 years, 50.8% female, mean STS score 6.0 ± 6.9%). The primary endpoint was all-cause mortality in the intent-to-treat population at 30 days and 1 year. An Extension cohort of 50 patients was treated with the Lotus valve with Depth Guard including a modified delivery system. Mortality and stroke were independently adjudicated. An independent core laboratory assessed echocardiographic data. Results: One-year clinical follow-up was available for 99.9% of Lotus valve-treated patients. At 1 year, the all-cause mortality rate was 11.7% and 4.1% of patients had experienced a disabling stroke. The permanent pacemaker implantation rate was 32% (37% among pacemaker-naive patients). Echocardiographic data at 1 year were available for core laboratory assessment in 62.6% of patients. Paravalvular leak was absent or trace in 94.5%, mild in 5.1%, and moderate in 0.4% of patients. Data from the Extension cohort confirmed good clinical outcomes at 30 days with an 18% permanent pacemaker rate (20% among pacemaker-naive patients). Conclusions: One-year outcomes from the RESPOND study confirm the safety and efficacy of the Lotus valve when used in routine clinical practice. (Repositionable Lotus Valve System—Post-Market Evaluation of Real World Clinical Outcomes [RESPOND]; NCT02031302

    A novel paclitaxe-eluting stent with an ultrathin abluminal biodegradeable polymer 9-month outcomes with the JACTAX HD stent

    Get PDF
    ObjectivesThe JACTAX HD trial (“JACTAX” Trial Drug Eluting Stent Trial) evaluated the safety and clinical performance of a novel JACTAX HD (Boston Scientific Corporation, Natick, Massachusetts) paclitaxel-eluting stent (PES) in de novo coronary lesions.BackgroundThe JACTAX HD (Boston Scientific) stent consists of a pre-crimped bare-metal Liberté (Boston Scientific) stent coated on its abluminal aspect with an ultrathin (&lt;1 ?m) 1/1 mixture of biodegradable polylactide polymer and paclitaxel applied as discrete microdots (nominal totals of 9.2 ?g each of polymer and paclitaxel per 16-mm stent).MethodsIn this prospective, single-arm, multicenter, first-human-use study (n = 103), the primary end point of 9-month major adverse cardiac events (MACE) (cardiac death, myocardial infarction, ischemia-related target vessel revascularization) was compared with an objective performance criterion (OPC) of 17% (11% MACE based on TAXUS ATLAS [TAXUS Liberté-SR Stent for the Treatment of de Novo Coronary Artery Lesions] trial results plus a pre-specified noninferiority margin of 6%).ResultsThe composite primary end point occurred in 7.8% of JACTAX HD patients with an upper 1-sided 95% confidence limit of 13.6%, thus meeting the pre-specified criteria for noninferiority. There was no death, Q-wave myocardial infarction, or stent thrombosis through 9 months. In-stent late loss was 0.33 ± 0.45 mm, with an in-stent binary restenosis of 5.2% and net volume obstruction by intravascular ultrasound of 11.4 ± 11.2%.ConclusionsThe JACTAX HD stent with an abluminal biodegradable polymer showed 9-month MACE, in-stent late loss, restenosis, and net volume obstruction comparable to that observed with the TAXUS Liberté (Boston Scientific) stent coated with a conformal durable polymer. Further studies are underway to better evaluate the potential of this new PES design, which might allow for more rapid endothelialization and improved vessel healing. (“JACTAX” Trial Drug Eluting Stent Trial; NCT00754728

    Postgenomic Approaches to Analyse Candida albicans Pathogenicity

    No full text