141 research outputs found
Spatial Stereoresolution for Depth Corrugations May Be Set in Primary Visual Cortex
Stereo “3D” depth perception requires the visual system to extract binocular disparities between the two eyes' images. Several current models of this process, based on the known physiology of primary visual cortex (V1), do this by computing a piecewise-frontoparallel local cross-correlation between the left and right eye's images. The size of the “window” within which detectors examine the local cross-correlation corresponds to the receptive field size of V1 neurons. This basic model has successfully captured many aspects of human depth perception. In particular, it accounts for the low human stereoresolution for sinusoidal depth corrugations, suggesting that the limit on stereoresolution may be set in primary visual cortex. An important feature of the model, reflecting a key property of V1 neurons, is that the initial disparity encoding is performed by detectors tuned to locally uniform patches of disparity. Such detectors respond better to square-wave depth corrugations, since these are locally flat, than to sinusoidal corrugations which are slanted almost everywhere. Consequently, for any given window size, current models predict better performance for square-wave disparity corrugations than for sine-wave corrugations at high amplitudes. We have recently shown that this prediction is not borne out: humans perform no better with square-wave than with sine-wave corrugations, even at high amplitudes. The failure of this prediction raised the question of whether stereoresolution may actually be set at later stages of cortical processing, perhaps involving neurons tuned to disparity slant or curvature. Here we extend the local cross-correlation model to include existing physiological and psychophysical evidence indicating that larger disparities are detected by neurons with larger receptive fields (a size/disparity correlation). We show that this simple modification succeeds in reconciling the model with human results, confirming that stereoresolution for disparity gratings may indeed be limited by the size of receptive fields in primary visual cortex
First- and second-order contributions to depth perception in anti-correlated random dot stereograms.
The binocular energy model of neural responses predicts that depth from binocular disparity might be perceived in the reversed direction when the contrast of dots presented to one eye is reversed. While reversed-depth has been found using anti-correlated random-dot stereograms (ACRDS) the findings are inconsistent across studies. The mixed findings may be accounted for by the presence of a gap between the target and surround, or as a result of overlap of dots around the vertical edges of the stimuli. To test this, we assessed whether (1) the gap size (0, 19.2 or 38.4 arc min) (2) the correlation of dots or (3) the border orientation (circular target, or horizontal or vertical edge) affected the perception of depth. Reversed-depth from ACRDS (circular no-gap condition) was seen by a minority of participants, but this effect reduced as the gap size increased. Depth was mostly perceived in the correct direction for ACRDS edge stimuli, with the effect increasing with the gap size. The inconsistency across conditions can be accounted for by the relative reliability of first- and second-order depth detection mechanisms, and the coarse spatial resolution of the latter
of depth perception
Stereo vision is an area in which we are increasingly able to construct detailed numerical models of the computations carried out by cerebral cortex. Piecewise-frontoparallel cross-correlation is one such model, closely based on the known physiology and able to explain important aspects of human stereo depth perception. Here, we show that it predicts important differences in the ability to detect disparity gratings with square-wave vs. sine-wave profiles. In particular, the model can detect square-wave gratings up to much higher disparity amplitudes than sine-wave gratings. We test this prediction in human subjects and find that it is not borne out. Rather there seems to be little or no difference between the detectability of square-and sine-wave disparity gratings for human subjects. We conclude that the model needs further refinement in order to capture this aspect of human stereo vision
Repetition priming results in sensitivity attenuation
International audienceRepetition priming refers to the change in the ability to perform a task on a stimulus as a consequence of a former encounter with that very same item. Usually, repetition results in faster and more accurate performance. In the present study, we used a contrast discrimination protocol to assess perceptual sensitivity and response bias of Gabor gratings that are either repeated (same orientation) or alternated (different orientation). We observed that contrast discrimination performance is worse, not better, for repeated than for alternated stimuli. In a second experiment, we varied the probability of stimulus repetition, thus testing whether the repetition effect is due to bottom-up or top-down factors. We found that it is top-down expectation that determines the effect. We discuss the implication of these findings for repetition priming and related phenomena as sensory attenuation
Enzyme-catalysed oxidation of 1,2-disulfides to yield chiral thiosulfinate, sulfoxide and cis-dihydrodiol metabolites
Oxidative biotransformations of 1,2-disulfides using bacterial whole cells and pure enzymes yielded an unexpectedly wide range of products including thiolactones and chiral thiosulfinate, sulfoxide,cis-diol and metabolites.</p
- …