2 research outputs found

    The Functional Hearing Gain with an Active Transcutaneous Bone Conduction Implant Does Not Correlate with the Subjective Hearing Performance

    No full text
    The functional hearing outcome with hearing implants does not always properly reflect the subjective benefit in everyday listening situations. In this study, the functional hearing gain and the impact on the subjective hearing ability and quality of life were assessed in patients with a Bonebridge. A chart review was performed on 45 patients with a Bonebridge who were provided with questionnaires regarding the hearing quality and health-related quality of life during their last clinical visit. The questionnaires consisted of the Speech, Spatial and Qualities (SSQ) and the Health Utility Index Mark 3 (HUI3). Eleven patients had to be excluded due to missing data. A total of 34 patients (37 ears) were included in the study. Aided hearing thresholds were significantly lower compared with the unaided condition, with a mean functional gain of 26.87 dB for patients with mixed/conductive hearing loss (MHL/CHL). Although patients with single-sided deafness (SSD) scored slightly lower on the SSQ compared with patients with MHL/CHL, all included patients reported improved subjective hearing quality with the BB compared with the hearing situation before implantation. No correlation was found between the functional hearing gain and the subdomains of the SSQ. SSD patients scored the HUI3 subdomain “hearing” slightly lower compared with MHL/CHL patients. Although not significant, a relationship was found between the functional gain and the “hearing” subdomain. No correlation was found for the other subdomains of the HUI3. Audiological measurements showed significantly improved hearing thresholds with the Bonebridge. Most importantly, the subjective benefit achieved in everyday listening situations was superior compared with the previous hearing condition. The lack of correlation between subjective questionnaire results and the functional hearing gain shows the importance of assessing both audiological and subjective hearing quality parameters in clinical routine

    Titanium and Platinum–Fluoroplastic Stapes Prostheses Visualization on Cone Beam Computed Tomography and High-Resolution Computed Tomography

    No full text
    Objective: The aim of this study was to evaluate whether stapes prostheses can be visualized with less metal artifacts and therefore more accurately on cone beam computed tomography in comparison to computed tomography imaging. Recent studies have shown that cone beam computed tomography has advantages when imaging metal artifacts. Patients with hearing loss or vertigo, who have undergone stapedotomy, often present a challenge for otologic surgeons. Imaging studies can deliver crucial additional information. Methods: A retrospective analysis of imaging studies and clinical data in a tertiary care center were carried out. Forty-one patients with forty-five implanted ears were evaluated in the study. All included patients had been implanted with a platinum–fluoroplastic (n = 19) or titanium (n = 26) piston and subsequently had undergone imaging months or years after surgery for various reasons. Patients underwent computed tomography or cone beam computed tomography of the temporal bone depending on availability. Piston visualization, prosthesis length, vestibular intrusion and audiologic results were compared between the groups. Piston position on imaging studies were compared to intraoperative findings. Results: Functional length measurements of all prostheses were carried out with a mean error of −0.17 mm (±0.20). Platinum–fluoroplastic protheses were significantly underestimated in length compared to titanium prostheses. To analyze the material-dependent difference in the measurement errors of the imaging techniques the interaction was tested in an ANOVA model and showed no statistically significant result (p = 0.24). The blinded neuroradiologist viewed two implants, both platinum–fluoroplastic pistons, as located outside of the vestibule due to an underestimation of the prothesis length and the missing radiodensity of the lower end of the prosthesis. Conclusion: Surgeons and radiologists should be aware of the different types and radiologic features of stapes prostheses and the missing radiodensity of some protheses parts. Cone beam computed tomography is an imaging alternative with a potential advantage of reduced radiation in patients after stapes surgery suffering from vertigo or hearing loss to evaluate piston position
    corecore