5 research outputs found

    Quantity and Quality of Vision Using Tinted Filters in Patients with Low Vision Due to Diabetic Retinopathy.

    Full text link
    [en] PURPOSE: To investigate the effect of tinted filters on visual acuity (VA), contrast sensitivity and patient satisfaction in diabetic retinopathy associated with low vision. METHODS: In a prospective study, 51 patients with diabetic retinopathy and low vision were assessed. We chose a simple random sampling method and used the patient's files for data collection. LogMAR notations were applied for assessing VA and a contrast sensitivity chart (CSV-1000) was employed for measuring contrast sensitivity. First, measurements were performed without tinted filters and then using them. Appropriate lenses were given to the patients for 2 days, and they were questioned about their satisfaction using them in different places. RESULTS: A total of 20 male and 31 female patients with mean age of 57.3 years participated in the study. With a 527 ± 10 nm filter, mean VA improved significantly (P ≤ 0.05). Using the 527 ± 10 nm and 511 ± 10 nm filters, mean contrast sensitivity was improved significantly at 3 and 6 cycles/degree frequencies (P < 0.05). The effect of other filters on VA and contrast sensitivity was not significant. Patient satisfaction rate was generally high. CONCLUSION: Tinted filters are able to rehabilitate low-vision patients due to diabetic retinopathy. The 527 ± 10 and 511 ± 10 nm wavelength filters improved contrast sensitivity and the 527 ± 10 nm filter improved VA to some extent. Further investigations are recommended to assess the effect of these filters in patients with other causes of low-vision

    Comparison among Ocular Response Analyzer, Corvis ST and Goldmann applanation tonometry in healthy children

    Get PDF
    AIM: To explore the relationship between different parameters of Ocular Response Analyzer (ORA) and Corvis ST (CST) in a sample of healthy Iranian school-aged children and the relationship between parameters of these 2 instruments against intraocular pressure (IOP), measured by the Goldmann applanation tonometer (GAT-IOP), age and gender, and find possible correlation between ORA and CST with GAT. METHODS: This cross-sectional study included 90 healthy children. A general interview and complete eye examination were performed. Following successful GAT-IOP measurement, ORA and CST were conducted. The CST parameters were A 1/2 length (A1L, A2L), A 1/2 velocity (A1V, A2V), highest concavity deformation amplitude (HCDA), radius of curvature (RoC), peak distance (PD), central corneal thickness (CCT) and IOP. The ORA parameters were corneal hysteresis (CH), corneal resistance factor (CRF), Goldmann-correlated IOP (IOP-G) and corneal compensated IOP (IOP-CC). Extracted data was analyzed using the Statistical Package for Social Science software. RESULTS: Totally 39 males with age of 9.08±1.60 (6-12)y and 51 females with age of 8.96±1.55 (6-13)y were included. Many CST parameters were significantly correlated with CH, CRF, IOP-G and IOP-CC. Some CST parameters had a significant correlation with GAT-IOP, including IOP-CST in both eyes and HCDA, A2L, PD, and RoC in the left eye, but none with age, except A2L in the right eye. The CRF measurement showed a significant correlation with GAT-IOP in both eyes and CH in the right eye, yet, none with age. Among all CST and ORA parameters, CCT-CST in both eyes and A1L in right eye had a significant correlation with gender, although this was a negligible negative correlation. Comparison of mean IOP values by different devices showed a significantly highest IOP overestimation by CST and lowest by IOP-CC compared with GAT. Also, IOP-G versus IOP-CST significantly had the lowest IOP overestimation among others. Overall, either low positive correlation or negligible correlation was found between IOP measurements by 3 instruments. CONCLUSION: The study finds the highest IOP overestimation by CST and lowest by IOP-CC compared with GAT. Overall, either low positive correlation or negligible correlation is found between IOP measurements by the 3 instruments

    Choroidal thickness changes following cataract surgery in patients with type 2 diabetes mellitus

    No full text
    Purpose: To evaluate the choroidal thickness changes after cataract surgery in type 2 diabetic patients. Methods: Three groups of patients were enrolled into this prospective study. Group A included diabetic patients without diabetic retinopathy (DR) or with mild non-proliferative diabetic retinopathy (NPDR) who underwent phacoemulsification, Group B included non-diabetic patients with significant cataract who underwent phacoemulsification, and Group C included diabetic patients without DR or with mild NPDR who followed up without surgical procedure. Choroidal thickness in 5 points (subfoveal and 500 μ temporal, nasal, superior and inferior to the fovea) and central macular thickness were measured before surgery using enhanced depth spectral domain optical coherence tomography. Patients were re-evaluated 1 week, 1 month, and 3 months after operation and compared with the baseline values. Results: In total, 63 eyes from 63 patients were enrolled to this study, including 21 eyes in Group A, 22 eyes in Group B, and 20 eyes in Group C. After three months of follow-up of the patients, choroidal thickness in all measured points was decreased significantly, and central macular thickness was increased significantly following cataract surgery in diabetic eyes (Ggroup A); meanwhile, both choroidal thickness and central macular thickness were increased significantly in non-diabetic eyes (Group B). In Group C, choroidal thickness and central macular thickness had no significant changes, after three months. Conclusion: Unlike in non-diabetic eyes, choroidal thickness in diabetic patients decreased following cataract surgery. Keywords: Choroidal thickness, Diabetic retinopathy, Cataract surgery, Phacoemulsification, Optical coherence tomograph
    corecore