150 research outputs found

    Soft mode dynamics of ferroelectric relaxors

    Get PDF
    International audienceHyper-Raman scattering is a non-linear inelastic spectroscopy sensitive to polar excitations of solids whatever the crystalline symmetry. This selection rule is very attractive in particular for centrosymmetric structures for which polar modes are inactive in Raman. HRS has been performed in the cubic relaxors PbMg1/3Nb2/3O3 (PMN) and PbMg1/3Ta2/3O3 (PMT), with particular attention to the low frequency region, down to about 2 cm-1. Spectra have been recorded over a wide temperature range (900K-30K in PMN) and the results compared to existing infrared and neutron scattering data. This complete set of vibrational information provides the framework for a detailed analysis of the polarization dynamics in these systems. In particular, in both materials, the soft mode response exhibits a doublet structure up to the highest temperature investigated [1,2] emphasizing therefore a common property of cubic relaxors. The lowest frequency component is assigned to the primary soft mode of symmetry F1u, while the second likely originates from a local disorder persisting until very high temperatures, and which lifts the cubic selection rules. On cooling, the soft F1u-mode of PMN becomes overdamped at the onset of the Burns temperature but very interestingly, it splits between 600K and 400K into two components which harden on decreasing further the temperature. This behavior likely highlights the onset of a local anisotropy of the polarization and provides therefore new insight about the relaxor nature

    In situ characterization of the decomposition behavior of Mg(BH4)(2) by X-ray Raman scattering spectroscopy

    Get PDF
    We present an in situ study of the thermal decomposition of Mg(BH4)(2) in a hydrogen atmosphere of up to 4 bar and up to 500 degrees C using X-ray Raman scattering spectroscopy at the boron K-edge and the magnesium L2,3-edges. The combination of the fingerprinting analysis of both edges yields detailed quantitative information on the reaction products during decomposition, an issue of crucial importance in determining whether Mg(BH4)(2) can be used as a next-generation hydrogen storage material. This work reveals the formation of reaction intermediate(s) at 300 degrees C, accompanied by a significant hydrogen release without the occurrence of stable boron compounds such as amorphous boron or MgB12H12. At temperatures between 300 degrees C and 400 degrees C, further hydrogen release proceeds via the formation of higher boranes and crystalline MgH2. Above 400 degrees C, decomposition into the constituting elements takes place. Therefore, at moderate temperatures, Mg(BH4)(2) is shown to be a promising high-density hydrogen storage material with great potential for reversible energy storage applications.Peer reviewe

    Low-energy electronic excitations and band-gap renormalization in CuO

    Get PDF
    Combining nonresonant inelastic x-ray scattering experiments with state-of-the-art ab initio many-body calculations, we investigate the electronic screening mechanisms in strongly correlated CuO in a large range of energy and momentum transfers. The excellent agreement between theory and experiment, including the low-energy charge excitations, allows us to use the calculated dynamical screening as a safe building block for many-body perturbation theory and to elucidate the crucial role played by d-d excitations in renormalizing the band gap of CuO. In this way we can dissect the contributions of different excitations to the electronic self-energy which is illuminating concerning both the general theory and this prototypical material.Combining nonresonant inelastic x-ray scattering experiments with state-of-the-art ab initio many-body calculations, we investigate the electronic screening mechanisms in strongly correlated CuO in a large range of energy and momentum transfers. The excellent agreement between theory and experiment, including the low-energy charge excitations, allows us to use the calculated dynamical screening as a safe building block for many-body perturbation theory and to elucidate the crucial role played by d-d excitations in renormalizing the band gap of CuO. In this way we can dissect the contributions of different excitations to the electronic self-energy which is illuminating concerning both the general theory and this prototypical material.Combining nonresonant inelastic x-ray scattering experiments with state-of-the-art ab initio many-body calculations, we investigate the electronic screening mechanisms in strongly correlated CuO in a large range of energy and momentum transfers. The excellent agreement between theory and experiment, including the low-energy charge excitations, allows us to use the calculated dynamical screening as a safe building block for many-body perturbation theory and to elucidate the crucial role played by d-d excitations in renormalizing the band gap of CuO. In this way we can dissect the contributions of different excitations to the electronic self-energy which is illuminating concerning both the general theory and this prototypical material.Peer reviewe

    A successful chronic care program in Al Ain-United Arab Emirates

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>The cost effective provision of quality care for chronic diseases is a major challenge for health care systems. We describe a project to improve the care of patients with the highly prevalent disorders of diabetes and hypertension, conducted in one of the major cities of the United Arab Emirates.</p> <p>Settings and Methods</p> <p>The project, using the principles of quality assurance cycles, was conducted in 4 stages.</p> <p>The assessment stage consisted of a community survey and an audit of the health care system, with particular emphasis on chronic disease care. The information gleaned from this stage provided feedback to the staff of participating health centers. In the second stage, deficiencies in health care were identified and interventions were developed for improvements, including topics for continuing professional development.</p> <p>In the third stage, these strategies were piloted in a single health centre for one year and the outcomes evaluated. In the still ongoing fourth stage, the project was rolled out to all the health centers in the area, with continuing evaluation. The intervention consisted of changes to establish a structured care model based on the predicted needs of this group of patients utilizing dedicated chronic disease clinics inside the existing primary health care system. These clinics incorporated decision-making tools, including evidence-based guidelines, patient education and ongoing professional education.</p> <p>Results</p> <p>The intervention was successfully implemented in all the health centers. The health care quality indicators that showed the greatest improvement were the documentation of patient history (e.g. smoking status and physical activity); improvement in recording physical signs (e.g. body mass index (BMI)); and an improvement in the requesting of appropriate investigations, such as HbA1c and microalbuminurea. There was also improvement in those parameters reflecting outcomes of care, which included HbA1c, blood pressure and lipid profiles. Indicators related to lifestyle changes, such as smoking cessation and BMI, failed to improve.</p> <p>Conclusion</p> <p>Chronic disease care is a joint commitment by health care providers and patients. This combined approach proved successful in most areas of the project, but the area of patient self management requires further improvement.</p
    • …
    corecore