5 research outputs found

    The Evaluation of a Low-Cost Colorimeter for Glucose Detection in Salivary Samples

    No full text
    Given the limited access to healthcare resources, low-income settings require the development of affordable technology. Here we present the design and evaluation of a low-cost colorimeter applied to the non-invasive monitoring of Diabetes Mellitus through the detection of glucose in salival fluid. Samples were processed by the glucose oxidase-peroxidase enzymatic system and analyzed with the development equipment. A light emission diode of 532.5 nm was used as an excitation source and a RGB module was used as a receptor. A calibration curve to quantify the concentration of salivary glucose (0 to 18 mg/dL) was carried out by relating the RGB components registered with glucose concentrations, achieving a limit of detection of 0.17 mg/dL with a CV of 5% (n = 3). Salivary samples of diabetic and healthy volunteers were processed with the equipment showing an average concentration of 1.5519 ± 0.4511 mg/dL for the first and 4.0479 ± 1.6103 mg/dL for the last, allowing a discrimination between both groups. Results were validated against a UV-Vis-NIR spectrophotometer with a correspondence of R2 of 0.98194 between both instruments. Results suggest the potential application of the developed device to the sensitive detection of relevant analytes with a low-cost, user-friendly, low-power and portable instrumentation

    Naked-Eye Detection of Glucose in Saliva with Bienzymatic Paper-Based Sensor

    No full text
    The high incidence of Diabetes Mellitus in low-income regions has promoted the development of low-cost alternatives to replace blood-based procedures. In this work, we present a bienzymatic paper-based sensor suitable for the naked-eye detection of glucose in saliva samples. The sensor was obtained by a stamping procedure and modified with chitosan to improve the colorimetric readout. The bienzymatic reaction of GOx-HRP coupled with 2,4,6-tribromo-3-hydroxy benzoic acid was applied for the detection of glucose within a range from 0 to 180 mgdL−1 in buffer and artificial saliva solutions. The visual readout was perceived by the naked eye and registered with an office scanner to evaluate the analytical performance. The results showed a limit of detection of 0.37 mgdL−1 (S/N = 3) with an R.S.D. of 1.69% and a linear range from 1 to 22.5 mgdL−1 with an R2 of 0.99235. The analysis of human saliva samples was performed without pre-processing, achieving recoveries from 92 to 114%. The naked-eye detection was evaluated under two different light settings, showing average recoveries of 108.58 and 90.65% for standard and low illumination. The proposed device showed potential for easy-to-use, sensitive, low-cost, fast, and device-free detection of salivary glucose suitable for untrained personnel operation and limited facilities

    Room Temperature Detection of Acetone by a PANI/Cellulose/WO3 Electrochemical Sensor

    No full text
    Chemical sensing based on semiconducting metal oxides has been largely proposed for acetone sensing, although some major technical challenges such as high operating temperature still remain unsolved. This work presents the development of an electrochemical sensor based on nanostructured PANI/cellulose/WO3 composite for acetone detection at room temperature. The synthesized materials for sensor preparation were polyaniline (PANI) with a conductivity of 13.9 S/cm and tungsten trioxide (WO3) in monoclinic phase doped with cellulose as carbon source. The synthesized materials were characterized by high resolution transmission electron microscopy (HRTEM), X-ray diffraction (XRD), cyclic voltammetry (CV), and Raman spectroscopy. The composite was applied for acetone detection in the range of 0 to 100 ppmv at room temperature with electrochemical impedance spectroscopy (EIS) for monitoring resistance changes proportional to acetone concentration. The developed sensor achieved a calculated limit of detection of 10 ppm and R2 of 0.99415 with a RSD of 5% (n=3) at room temperature. According to these results, the developed sensor is suitable for acetone sensing at room temperatures without the major shortcomings of larger systems required by high operating temperatures
    corecore