3 research outputs found

    Stability at the half pin-frame interface on external fixation constructs

    Get PDF
    Abstract A mechanical study investigating the use of two different methods (grub and bolt screws) to secure external fixation half pins to circular frames. A four part experiment: (1) Grub and bolt screws were used to secure half pins in Taylor Spatial frames. Loosening torques were measured using a calibrated torque wrench. (2) Using universal testing machine (UTM), axial loading was applied to establish thresholds for loosening in grub and bolt screw constructs. (3) We established the application torque to produce failure at the head–driver interface using these two methods. (4) Grub and bolt screw constructs were created controlling torque. Using UTM, axial loading was applied to establish thresholds for loosening. Statistical analysis was conducted using SPSS v20.0.0. (1) Higher torque is employed when bolt rather than grub screws is used to secure half pins on Rancho cubes (p < 0.05). (2) Loading threshold for loosening is higher in bolt screw constructs when the torque applied to secure the constructs is not controlled (p < 0.05). (3) Torque required for failure at the head–driver interface was 5.3 Nm for grub screws and 9.9 Nm for bolts. (4) Loading threshold for loosening is higher in grub screw constructs when the same torque was applied to secure them (p < 0.05). Bolt screws can be employed to secure the half pin–frame interface. They offer good stability and reduce failure at the head–driver interface. Further research is needed to determine the mechanical properties of such constructs in vivo

    Osteocutaneous Turn-Up Fillet Flaps: A Spare-Parts Orthoplastic Surgery Option for a Functional Posttraumatic Below-Knee Amputation

    No full text
    This article portrays the authors' experience with a complex lower limb bone and soft tissue defect, following chronic osteomyelitis and pathological fracture, which was managed by the multidisciplinary orthoplastic team. The decision for functional amputation versus limb salvage was deemed necessary, enhanced by the principles of “spare parts” in reconstructive microsurgery. This case describes the successful use of the osteocutaneous distal tibia turn-up fillet flap that allowed “lowering the level of the amputation” from a through knee to a below-knee amputation (BKA) to preserve the knee joint function. We comprehensibly review reports of turn-up flaps which effectively lower the level of amputation, also applying “spare-parts” surgery principles and explore how these concepts refine complex orthoplastic approaches when limb salvage is not possible to enhance function. The osteocutaneous distal tibia turn-up fillet flap is a robust technique for modified BKA reconstructions that provides sufficient bone length to achieve a tough, sensate stump and functional knee joint

    The Operative Management of Patella Malalignment

    No full text
    corecore