95 research outputs found
General Information About the Design of Smart Grids in Universities
Until recently, the dominant paradigm in the electrification consisted of universal service and its centralization, and for loor modern times think of the power grid of the future where a qualitative and radical leap is required because of the need to manage better energy resources, promote environmental protection and meet the increasingly demanding requirements of quality of service. A power distribution network becomes intelligent acquiring data, communicating, processing information and exercising control through a feedback that allows you to adjust to changes that may arise in actual operation. Ecuador aimed at energy efficiency through smart grids, which allow the dealer to maintain absolute monitoring of energy flow and the elements of the power grid. Thus, it is possible that service companies can efficiently manage their assets and the end user to manage consumption rationally, requiring to enhance the energy efficiency of power grids, one management timely and efficient energy
Tetrathiotetracene thin film morphology and electrical properties
The electrical properties of organic thin films are determined by their chemical constituents and the morphology of the films deposited. In this paper the morphology of vacuum sublimed (7∙10-6 mbar) tetrathiotetracene (TTT) thin films is shown to be strongly affected by the thermal deposition temperature (222-350 K) and rate of deposition. Mostly needle-like morphologies are identified by scanning electron microscopy. Optimal TTT purity (a pre-requisite for device preparation via subsequent oxidation) is evidenced by their initially low electrical conductivity. Altering the TTT morphology, by variation of the evaporation parameters, strongly affects this base electrical conductivity. Four probe conductivity measurements and charge extraction by linear increasing voltage methods are used to characterize film electrical properties. In-plane conductivity of up to 7.03∙10-5 S/cm is achieved for pure TTT thin films. Subsequent aerial oxidation resulted in a 3.4-fold increase in electrical conductivity
Shaking table tests and numerical analyses on a scaled dry-joint arch undergoing windowed sine pulses
The damages occurred during recent seismic events have emphasised the vulnerability of vaulted masonry structures, one of the most representative elements of worldwide cultural heritage. Although a certain consensus has been reached regarding the static behaviour of masonry arches, still more efforts are requested to investigate their dynamic behaviour. In this regard, the present paper aims to investigate the performance of a scaled dry-joint arch undergoing windowed sine pulses. A feature tracking based measuring technique was employed to evaluate the displacement of selected points, shading light on the failure mechanisms and gathering data for the calibration of the numerical model. This was built according to a micro-modelling approach of the finite element method, with voussoirs assumed very stiff and friction interface elements. Comparisons with existing literature are also stressed, together with comments about scale effects.This work was partly financed by FEDER funds through the Competitivity Factors Operational Programme-COMPETE and by national funds through FCT-Foundation for Science and Technology within the scope of the Project POCI-01-0145-FEDER-007633.info:eu-repo/semantics/publishedVersio
In silico transcriptional regulation and functional analysis of dengue shock syndrome associated SNPs in PLCE1 and MICB genes
YesSingle nucleotide polymorphisms (SNPs) in PLCE1
and MICB genes increase risk for the development of dengue
shock syndrome (DSS). We used Bioinformatics tools to predict
alterations at the transcriptional and posttranslational levels
driven by PLCE1 and MICB SNPs associated with DSS.
Functional and phenotypic analysis conducted to determine
deleterious SNPs and impact of amino acid substitution on
the structure and function of proteins identified rs2274223
(H1619R) as deleterious to protein coding as it induces structural
change in the C2 domain of PLCε, with the mutant residue
more positively charged than the wild-type residue (RMSD
score, 1.75 Å).Moreover, rs2274223 condenses the chromatinrepressing
PLCε expression in DSS. Briefly, this study presents
the impact of a single nucleotide transition at SNPs associated
with DSS on differential protein binding patterns with PLCE1
and MICB genes and on protein structure modification and their
possible role in the pathogenesis of DSS
Comparison of two recombinant erythropoietin formulations in patients with anemia due to end-stage renal disease on hemodialysis: A parallel, randomized, double blind study
BACKGROUND: Recombinant human erythropoietin (EPO) is used for the treatment of last stage renal anemia. A new EPO preparation was obtained in Cuba in order to make this treatment fully nationally available. The aim of this study was to compare the pharmacokinetic, pharmacodynamic and safety properties of two recombinant EPO formulations in patients with anemia due to end-stage renal disease on hemodialysis. METHODS: A parallel, randomized, double blind study was performed. A single 100 IU/Kg EPO dose was administered subcutaneously. Heberitro (Heber Biotec, Havana, formulation A), a newly developed product and Eprex (CILAG AG, Switzerland, formulation B), as reference treatment were compared. Thirty-four patients with anemia due to end-stage renal disease on hemodialysis were included. Patients had not received EPO previously. Serum EPO level was measured by enzyme immunoassay (EIA) during 120 hours after administration. Clinical and laboratory variables were determined as pharmacodynamic and safety criteria until 216 hours. RESULTS: Both groups of patients were similar regarding all demographic and baseline characteristics. EPO kinetics profiles were similar for both formulations; the pharmacokinetic parameters were very close (i.e., AUC: 4667 vs. 4918 mIU.h/mL; Cmax: 119.1 vs. 119.7 mIU/mL; Tmax: 13.9 vs. 18.1 h; half-life, 20.0 vs. 22.5 h for formulations A and B, respectively). The 90% confidence intervals for the ratio between both products regarding these metrics were close to the 0.8 – 1.25 range, considered necessary for bioequivalence. Differences did not reach 20% in any case and were not determined by a formulation effect, but probably by a patients' variability effect. Concerning pharmacodynamic features, a high similitude in reticulocyte counts increments until 216 hours and the percentage decrease in serum iron until 120 hours was observed. There were no differences between formulations regarding the adverse events and their intensity. The more frequent events were pain at injection site (35.3%) and hypertension (29%). Additionally, further treatment of the patients with the study product yielded satisfactory increases in hemoglobin and hematocrit values. CONCLUSION: The formulations are comparable. The newly developed product should be acceptable for long-term application
Structural appraisal of a Roman concrete vaulted monument: the Basilica of Maxentius
The Basilica of Maxentius, the largest vaulted space built by the Romans, comprised three naves, the outer ones covered by barrel vaults and the central, highest one by cross vaults. It was built on a sloping site, resulting in a possible structural vulnerability at its taller, western end. Two naves collapsed in the Middle Ages, leaving only the barrel vaults of the north nave. We describe surveys and analyses aimed at creating an accurate record of the current state of the structure, and reconstructing and analysing the original structure. Key features include distortions of the barrel vaults around windows and rotation of the west wall due to the thrust from the adjacent vault. Thrust line analysis results in a very low safety factor for the west façade. The geometry of the collapsed cross vaults was reconstructed from the remains using solid modelling and digital photogrammetry, and thrust line analysis confirmed that it was stable under gravity loads. A survey of the foundations and earlier structures under the collapsed south-west corner revealed horizontal slip and diagonal cracking in columns and walls; this is strong evidence that the site has been subject to seismic loading which may have caused the partial collapse. </p
- …