6 research outputs found

    Management of nystagmus in children: A review of the literature and current practice in UK specialist services

    Get PDF
    Nystagmus is an eye movement disorder characterised by abnormal, involuntary rhythmic oscillations of one or both eyes, initiated by a slow phase. It is not uncommon in the UK and regularly seen in paediatric ophthalmology and adult general/strabismus clinics. In some cases, it occurs in isolation, and in others, it occurs as part of a multisystem disorder, severe visual impairment or neurological disorder. Similarly, in some cases, visual acuity can be normal and in others can be severely degraded. Furthermore, the impact on vision goes well beyond static acuity alone, is rarely measured and may vary on a minute-to-minute, day-to-day or month-to-month basis. For these reasons, management of children with nystagmus in the UK is varied, and patients report hugely different experiences and investigations. In this review, we hope to shine a light on the current management of children with nystagmus across five specialist centres in the UK in order to present, for the first time, a consensus on investigation and clinical management

    Argus II retinal prosthesis for retinitis pigmentosa in the Middle East: The 2015 Pan-American Association of Ophthalmology Gradle Lecture

    No full text
    Background: To describe the outcomes of patients with retinitis pigmentosa (RP) who received the Argus II Retinal Prosthesis System. Methods: This retrospective, interventional case series evaluated 10 consecutive patients who received the Argus II retinal implant and underwent visual function tests with the system on and system off. The main outcome measures were safety (the number, seriousness, and relatedness of adverse events), and visual function measured by computer-based objective tests, including square localization (SL) and direction of motion (DOM). Secondary measures included functional vision performance, including orientation and mobility (O&M) tasks. Results: There were no intraoperative complications and all prostheses remained implanted at the end of follow up. The mean patient age was 41.3 years; mean duration of the implant in vivo was 2.1 years. One patient had a suture exposure over the coil suture tab and over the inferior case suture tab at 2 years postoperatively, which was managed successfully. One patient developed mild vitreous hemorrhage that resolved spontaneously. One patient developed high intraocular pressure postoperatively due to a tight scleral band (SB) that was managed successfully. Patients performed significantly better with the Argus II system on than off on all tasks. Conclusion: Patients who received the Argus II had a safety profile out to 4 years post-implantation that was markedly better than that observed in the pre-approval phase of the Argus II. In this population of RP patients, the Argus II retinal prosthesis provided useful visual function over several years that likely translates into improved quality of life. Trial Registration: clinicaltrials.gov identifier, NCT00407602

    Argus II retinal prosthesis for retinitis pigmentosa in the Middle East: The 2015 Pan-American Association of Ophthalmology Gradle Lecture

    No full text
    Background: To describe the outcomes of patients with retinitis pigmentosa (RP) who received the Argus II Retinal Prosthesis System. Methods: This retrospective, interventional case series evaluated 10 consecutive patients who received the Argus II retinal implant and underwent visual function tests with the system on and system off. The main outcome measures were safety (the number, seriousness, and relatedness of adverse events), and visual function measured by computer-based objective tests, including square localization (SL) and direction of motion (DOM). Secondary measures included functional vision performance, including orientation and mobility (O&M) tasks. Results: There were no intraoperative complications and all prostheses remained implanted at the end of follow up. The mean patient age was 41.3 years; mean duration of the implant in vivo was 2.1 years. One patient had a suture exposure over the coil suture tab and over the inferior case suture tab at 2 years postoperatively, which was managed successfully. One patient developed mild vitreous hemorrhage that resolved spontaneously. One patient developed high intraocular pressure postoperatively due to a tight scleral band (SB) that was managed successfully. Patients performed significantly better with the Argus II system on than off on all tasks. Conclusion: Patients who received the Argus II had a safety profile out to 4 years post-implantation that was markedly better than that observed in the pre-approval phase of the Argus II. In this population of RP patients, the Argus II retinal prosthesis provided useful visual function over several years that likely translates into improved quality of life. Trial Registration: clinicaltrials.gov identifier, NCT00407602
    corecore