81 research outputs found

    A Case of High-Grade Neuroendocrine Carcinoma That Improved with Bevacizumab plus Modified FOLFOX6 as the Fourth-Line Chemotherapy

    Get PDF
    High-grade neuroendocrine carcinoma differs from usual neuroendocrine carcinoma, and its prognosis is dismal. In this case report, a case of high-grade neuroendocrine carcinoma that improved with bevacizumab plus modified FOLFOX6 as the fourth-line chemotherapy is presented. A 29-year-old male with a huge liver tumor was diagnosed with high-grade neuroendocrine carcinoma originating from the liver. Multiple liver and bone metastases were found one month after surgery. He was treated with three chemotherapy regimens used for the management of small-cell lung cancer with extensive disease. However, none of them could be maintained because of tumor progression. He was then treated with bevacizumab plus modified FOLFOX6 as the fourth-line regimen. Dramatic tumor shrinkage was obtained, and a partial response was achieved. This case suggests that high-grade neuroendocrine carcinoma can be treated with bevacizumab in combination with cytotoxic chemotherapy

    The development of carbonate-containing apatite/collagen composite for osteoconductive apical barrier material.

    Get PDF
    The current report describes the properties of a new apical barrier material formulated from carbonate-containing apatite (CAp) and collagen. CAp particles of around 50 nm were deposited on reconstituted collagen fibers. CAp/col with about 60 wt % CAp (corresponding to apatite content of bone) was obtained after 1 day of calcification. CAp content increased up to about 80 wt % in a 15-day calcification reaction. CAp/col was composed of fine calcified collagen fibers. The crystallinity and Ca/PO(4) ratio of CAp were comparable to those of bone apatite. The mixture of CAp/col and saline reached a pH of about 9. The optimum powder-to-liquid ratio (P/L) to set into a root canal was determined to be 1.2. Furthermore, the mixture (P/L = 1.2) condensed in a root canal was liquid permeable. Thus, the CAp/col was expected as an apical barrier material with osteoconductivity.The current report describes the properties of a new apical barrier material formulated from carbonate-containing apatite (CAp) and collagen. CAp particles of around 50 nm were deposited on reconstituted collagen fibers. CAp/col with about 60 wt % CAp (corresponding to apatite content of bone) was obtained after 1 day of calcification. CAp content increased up to about 80 wt % in a 15-day calcification reaction. CAp/col was composed of fine calcified collagen fibers. The crystallinity and Ca/PO(4) ratio of CAp were comparable to those of bone apatite. The mixture of CAp/col and saline reached a pH of about 9. The optimum powder-to-liquid ratio (P/L) to set into a root canal was determined to be 1.2. Furthermore, the mixture (P/L = 1.2) condensed in a root canal was liquid permeable. Thus, the CAp/col was expected as an apical barrier material with osteoconductivity

    HAMAMATSU-ICG study: Protocol for a phase III, multicentre, single-arm study to assess the usefulness of indocyanine green fluorescent lymphography in assessing secondary lymphoedema

    Get PDF
    Introduction Secondary lymphoedema of the extremities is an important quality-of-life issue for patients who were treated for their malignancies. Indocyanine green (ICG) fluorescent lymphography may be helpful for assessing lymphoedema and for planning lymphaticovenular anastomosis (LVA). The objective of the present clinical trial is to confirm whether or not ICG fluorescent lymphography using the near-infrared monitoring camera is useful for assessing the indication for LVA, for the identification of the lymphatic vessels before the conduct of LVA, and for the confirmation of the patency of the anastomosis site during surgery. Methods and analysis This trial is a phase III, multicentre, single-arm, open-label clinical trial to assess the efficacy and safety of ICG fluorescent lymphography when assessing and treating lymphoedema of patients with secondary lymphoedema who are under consideration for LVA. The primary endpoint is the identification rate of the lymphatic vessels at the incision site based on ICG fluorescent lymphograms obtained before surgery. The secondary endpoints are 1) the sensitivity and specificity of dermal back flow determined by ICG fluorescent lymphography as compared with 99mTc lymphoscintigraphy—one of the standard diagnostic methods and 2) the usefulness of ICG fluorescent lymphography when confirming the patency of the anastomosis site after LVA. Ethics and dissemination The protocol for the study was approved by the Institutional Review Board of each institution. The trial was filed for and registered at the Pharmaceuticals and Medical Devices Agency in Japan. The trial is currently on-going and is scheduled to end in June 2020

    LODEWAVE: LOng-Duration balloon Experiment of gravity WAVE over Antarctica

    Get PDF
    The Tenth Symposium on Polar Science/Special session: [S] Future plan of Antarctic research: Towards phase X of the Japanese Antarctic Research Project (2022-2028) and beyond, Tue. 3 Dec. / Entrance Hall (1st floor) at National Institute of Polar Research (NIPR

    Detectability of colorectal neoplasia with fluorine-18-2-fluoro-2-deoxy-D-glucose positron emission tomography and computed tomography (FDG-PET/CT)

    Get PDF
    The purpose of this study was to analyze the detectability of colorectal neoplasia with fluorine-18-2-fluoro-2-deoxy-d-glucose positron emission tomography/computed tomography (FDG-PET/CT). Data for a total of 492 patients who had undergone both PET/CT and colonoscopy were analyzed. After the findings of PET/CT and colonoscopy were determined independently, the results were compared in each of the six colonic sites examined in all patients. The efficacy of PET/CT was determined using colonoscopic examination as the gold standard. In all, 270 colorectal lesions 5 mm or more in size, including 70 pathologically confirmed malignant lesions, were found in 172 patients by colonoscopy. The sensitivity and specificity of PET/CT for detecting any of the colorectal lesions were 36 and 98%, respectively. For detecting lesions 11 mm or larger, the sensitivity was increased to 85%, with the specificity remaining consistent (97%). Moreover, the sensitivity for tumors 21 mm or larger was 96% (48/50). Tumors with malignant or high-grade pathology were likely to be positive with PET/CT. A size of 10 mm or smaller [odds ratio (OR) 44.14, 95% confidence interval (95% CI) 11.44-221.67] and flat morphology (OR 7.78, 95% CI 1.79-36.25) were significant factors that were associated with false-negative cases on PET/CT. The sensitivity of PET/CT for detecting colorectal lesions is acceptable, showing size- and pathology-dependence, suggesting, for the most part, that clinically relevant lesions are detectable with PET/CT. However, when considering PET/CT for screening purposes caution must be exercised because there are cases of false-negative results

    Effects of synthesis conditions on the structural features and methane adsorption properties of single-walled carbon nanohorns prepared by a gas-injected arc-in-water method

    Get PDF
    Single-walled carbon nanohorns (SWCNHs) can be easily synthesized via a gas-injected arc-in-water method that is considered to be a cost-effective technique. The electrode configuration and duration of arc discharge were modified in order to enhance the yield and methane-adsorption properties of SWCNHs. As a result, the yield of the SWCNHs was significantly increased by increasing the discharge time and the size of the cathode. Using these modified conditions, the horn units in the SWCNH aggregates increased in size, and the thermal stability of SWCNHs in an oxidative environment increased accordingly. Ab initio molecular orbital calculations were used to explain the trend in the thermal stability. When the conventional conditions were applied, a burn-off of about 40% was necessary in order to achieve the maximum specific surface area and micropore volume. Remarkably, by enlarging the cathode size, the burn-off can be reduced by almost half to achieve the enhanced micropore volume. As a result, SWCNHs obtained using the modified conditions adsorbed a larger amount of methane than did SWCNHs obtained from the conventional synthetic conditions. The effect of a mild oxidation treatment on SWCNHs on their methane adsorption suggested that SWCNHs with micropores would be more flexible than pristine SWCNHs. This tendency was elucidated using a molecular mechanics calculation
    corecore