6 research outputs found
Recommended from our members
An Automated Method to Quantify Radiation Damage in Human Blood Cells
Cytogenetic analysis of blood lymphocytes is a well established method to assess the absorbed dose in persons exposed to ionizing radiation. Because mature lymphocytes circulate throughout the body, the dose to these cells is believed to represent the average whole body exposure. Cytogenetic methods measure the incidence of structural aberrations in chromosomes as a means to quantify DNA damage which occurs when ionizing radiation interacts with human tissue. Methods to quantify DNA damage at the chromosomal level vary in complexity and tend to be laborious and time consuming. In a mass casualty scenario involving radiological/nuclear materials, the ability to rapidly triage individuals according to radiation dose is critically important. For high-throughput screening for dicentric chromosomes, many of the data collection steps can be optimized with motorized microscopes coupled to automated slide scanning platforms
Interlaboratory comparison of the dicentric chromosome assay for radiation biodosimetry in mass casualty events
This interlaboratory comparison validates the dicentric chromosome assay for assessing radiation dose in mass casualty accidents and identifies the advantages and limitations of an international biodosimetry network. The assay's validity and accuracy were determined among five laboratories following the International Organization for Standardization guidelines. Blood samples irradiated at the Armed Forces Radiobiology Research Institute were shipped to all laboratories, which constructed individual radiation calibration curves and assessed the dose to dose-blinded samples. Each laboratory constructed a dose-effect calibration curve for the yield of dicentrics for 60Co γ rays in the 0 to 5-Gy range, using the maximum likelihood linear-quadratic model, Y = c + αD + βD2. For all laboratories, the estimated coefficients of the fitted curves were within the 99.7% confidence intervals (CIs), but the observed dicentric yields differed. When each laboratory assessed radiation doses to four dose-blinded blood samples by comparing the observed dicentric yield with the laboratory's own calibration curve, the estimates were accurate in all laboratories at all doses. For all laboratories, actual doses were within the 99.75% CI for the assessed dose. Across the dose range, the error in the estimated doses, compared to the physical doses, ranged from 15% underestimation to 15% overestimation
Biological dosimetry by the triage dicentric chromosome assay: Potential implications for treatment of acute radiation syndrome in radiological mass casualties
Biological dosimetry is an essential tool for estimating radiation dose. The dicentric chromosome assay (DCA) is currently the tool of choice. Because the assay is labor-intensive and time-consuming, strategies are needed to increase throughput for use in radiation mass casualty incidents. One such strategy is to truncate metaphase spread analysis for triage dose estimates by scoring 50 or fewer metaphases, compared to a routine analysis of 500 to 1000 metaphases, and to increase throughput using a large group of scorers in a biodosimetry network. Previously, the National Institutes for Allergies and Infectious Diseases (NIAID) and the Armed Forces Radiobiology Research Institute (AFRRI) sponsored a double-blinded interlaboratory comparison among five established international cytogenetic biodosimetry laboratories to determine the variability in calibration curves and in dose measurements in unknown, irradiated samples. In the present study, we further analyzed the published data from this previous study to investigate how the number of metaphase spreads influences dose prediction accuracy and how this information could be of value in the triage and management of people at risk for the acute radiation syndrome (ARS). Although, as expected, accuracy decreased with lower numbers of metaphase spreads analyzed, predicted doses by the laboratories were in good agreement and were judged to be adequate to guide diagnosis and treatment of ARS. These results demonstrate that for rapid triage, a network of cytogenetic biodosimetry laboratories can accurately assess doses even with a lower number of scored metaphases