Accuracy, repeatability, and reproducibility of T1 and T2 relaxation times measurement by 3D magnetic resonance fingerprinting with different dictionary resolutions
[Objectives] To assess the accuracy, repeatability, and reproducibility of T₁ and T₂ relaxation time measurements by three-dimensional magnetic resonance fingerprinting (3D MRF) using various dictionary resolutions. [Methods] The ISMRM/NIST phantom was scanned daily for 10 days in two 3 T MR scanners using a 3D MRF sequence reconstructed using four dictionaries with varying step sizes and one dictionary with wider ranges. Thirty-nine healthy volunteers were enrolled: 20 subjects underwent whole-brain MRF scans in both scanners and the rest in one scanner. ROI/VOI analyses were performed on phantom and brain MRF maps. Accuracy, repeatability, and reproducibility metrics were calculated. [Results] In the phantom study, all dictionaries showed high T₁ linearity to the reference values (R² > 0.99), repeatability (CV 0.98), repeatability (CV < 6%), and reproducibility (CV ≤ 4%) for T₂ measurement. The volunteer study demonstrated high T1 reproducibility of within-subject CV (wCV) < 4% by all dictionaries with the same ranges, both in the brain parenchyma and CSF. Yet, reproducibility was moderate for T₂ measurement (wCV < 8%). In CSF measurement, dictionaries with a smaller range showed a seemingly better reproducibility (T₁, wCV 3%; T₂, wCV 8%) than the much wider range dictionary (T₁, wCV 5%; T₂, wCV 13%). Truncated CSF relaxometry values were evident in smaller range dictionaries. [Conclusions] The accuracy, repeatability, and reproducibility of 3D MRF across various dictionary resolutions were high for T₁ and moderate for T₂ measurements. A lower-resolution dictionary with a well-defined range may be adequate, thus significantly reducing the computational load. [Key Points] • A lower-resolution dictionary with a well-defined range may be sufficient for 3D MRF reconstruction. • CSF relaxation times might be underestimated due to truncation by the upper dictionary range. • Dictionary with a higher upper range might be advisable, especially for CSF evaluation and elderly subjects whose perivascular spaces are more prominent
Comparison of TGSE-BLADE DWI, RESOLVE DWI, and SS-EPI DWI in healthy volunteers and patients after cerebral aneurysm clipping
Diffusion-weighted magnetic resonance imaging is prone to have susceptibility artifacts in an inhomogeneous magnetic field. We compared distortion and artifacts among three diffusion acquisition techniques (single-shot echo-planar imaging [SS-EPI DWI], readout-segmented EPI [RESOLVE DWI], and 2D turbo gradient- and spin-echo diffusion-weighted imaging with non-Cartesian BLADE trajectory [TGSE-BLADE DWI]) in healthy volunteers and in patients with a cerebral aneurysm clip. Seventeen healthy volunteers and 20 patients who had undergone surgical cerebral aneurysm clipping were prospectively enrolled. SS-EPI DWI, RESOLVE DWI, and TGSE-BLADE DWI of the brain were performed using 3 T scanners. Distortion was the least in TGSE-BLADE DWI, and lower in RESOLVE DWI than SS-EPI DWI near air–bone interfaces in healthy volunteers (P < 0.001). Length of clip-induced artifact and distortion near the metal clip were the least in TGSE-BLADE DWI, and lower in RESOLVE DWI than SS-EPI DWI (P < 0.01). Image quality scores for geometric distortion, susceptibility artifacts, and overall image quality in both healthy volunteers and patients were the best in TGSE-BLADE DWI, and better in RESOLVE DWI than SS-EPI DWI (P < 0.001). Among the three DWI sequences, image quality was the best in TGSE-BLADE DWI in terms of distortion and artifacts, in both healthy volunteers and patients with an aneurysm clip
Intake of Radionuclides in the Trees of Fukushima Forests 3. Removal of Radiocesium from Stem Wood, Cryptomeria Japonica (L.f.) D. Don.
Nuclear power plant accidents have dispersed radiocesium into the atmosphere to contaminate trees with no turnover in heartwood, as occurred in Fukushima, and as has persisted for over 30 years around Chernobyl. Here we employ the ponding method, in which radiocesium can be flushed out from the cross-cut edges of Japanese cedar, Cryptomeria japonica (L.f.) D. Don., stem with water due to xyloglucan degradation in tracheids. Furthermore, lab-scale ponding experiments have shown that a non-detectable level of radiocesium has been observed not only in the pool water used for 575 days but also in the water containing recombinant xyloglucanase. This traditional technology is now a new biotechnology
Hemosiderin Detection inside the Mammillary Bodies Using Quantitative Susceptibility Mapping on Patients with Wernicke-Korsakoff Syndrome
Hemorrhage inside the mammillary bodies (MMBs) is known to be one of the findings of Wernicke encephalopathy. Brain MRI of two patients with Wernicke-Korsakoff syndrome (WKS) demonstrated high susceptibility values representing hemosiderin deposition in MMBs by using quantitative susceptibility mapping (QSM). QSM provided additional information of susceptibility values to susceptibility-weighted imaging in diagnosis of WKS
Clinical Application of MPRAGE Wave Controlled Aliasing in Parallel Imaging (Wave-CAIPI): A Comparative Study with MPRAGE GRAPPA
PURPOSE: To compare reliability and elucidate clinical application of magnetization-prepared rapid gradient-echo (MPRAGE) with 9-fold acceleration by using wave-controlled aliasing in parallel imaging (Wave-CAIPI 3 × 3) in comparison to conventional MPRAGE accelerated by using generalized autocalibrating partially parallel acquisition (GRAPPA) 2 × 1. METHODS: A total of 26 healthy volunteers and 33 patients were included in this study. Subjects were scanned with two MPRAGEs, GRAPPA 2 × 1 and Wave-CAIPI 3 × 3 acquired in 5 min 21 s and 1 min 42 s, respectively, on a 3T MR scanner. Healthy volunteers underwent additional two MPRAGEs (CAIPI 3 × 3 and GRAPPA 3 × 3). The image quality of the four MPRAGEs was visually evaluated with a 5-point scale in healthy volunteers, and the SNR of four MPRAGEs was also calculated by measuring the phantom 10 times with each MPRAGE. Based on the results of the visual evaluation, voxel-based morphometry (VBM) analyses, including subfield analysis, were performed only for GRAPPA 2 × 1 and Wave-CAIPI 3 × 3. Correlation of segmentation results between GRAPPA 2 × 1 and Wave-CAIPI 3 × 3 was assessed. RESULTS: In visual evaluations, scores for MPRAGE GRAPPA 2 × 1 (mean rank: 4.00) were significantly better than those for Wave-CAIPI 3 × 3 (mean rank: 3.00), CAIPI 3 × 3 (mean rank: 1.83), and GRAPPA 3 × 3 (mean rank: 1.17), and scores for Wave-CAIPI 3×3 were significantly better than those for CAIPI 3 × 3 and GRAPPA 3 × 3. Image noise was evident at the center for additional MPRAGE CAIPI 3 × 3 and GRAPPA 3 × 3. The correlation of segmentation results between GRAPPA 2 × 1 and Wave-CAIPI 3 × 3 was higher than 0.85 in all VOIs except globus pallidus. Subfield analysis of hippocampus also showed a high correlation between GRAPPA 2 × 1 and Wave-CAIPI 3 × 3. CONCLUSION: MPRAGE Wave-CAIPI 3 × 3 shows relatively better contrast, despite of its short scan time of 1 min 42 s. The volumes derived from automated segmentation of MPRAGE Wave-CAIPI are considered to be reliable measures
Quiet Diffusion-weighted MR Imaging of the Brain for Pediatric Patients with Moyamoya Disease
PURPOSE: Diffusion-weighted MRI (DWI) is an essential sequence for evaluating pediatric patients with moyamoya disease (MMD); however, acoustic noise associated with DWI may lead to motion artifact. Compared with conventional DWI (cDWI), quiet DWI (qDWI) is considered less noisy and able to keep children more relaxed and stable. This study aimed to evaluate the suitability of qDWI compared with cDWI for pediatric patients with MMD. METHODS: In this observational study, MR examinations of the brain were performed either with or without sedation in pediatric patients with MMD between September 2017 and August 2018. Three neuroradiologists independently evaluated the images for artifacts and restricted diffusion in the brain. The differences between qDWI and cDWI were compared statistically using a chi-square test. RESULTS: One-hundred and six MR scans of 56 patients with MMD (38 scans of 15 sedated patients: 6 boys and 9 girls; mean age, 5.2 years; range, 1-9 years; and 68 scans of 42 unsedated patients: 19 boys and 23 girls; mean age, 10.7 years; range, 7-16 years) were evaluated. MR examinations were performed either with or without sedation (except in one patient). In sedated patients, no artifact other than susceptibility was observed on qDWI, whereas four artifacts were observed on cDWI (P = .04). One patient awoke from sedation during cDWI scanning, while no patient awoke from sedation during qDWI acquisition. For unsedated patients, three scans showed artifacts on qDWI, whereas two scans showed artifacts on cDWI (P = .65). Regarding restricted diffusion, qDWI revealed three cases, while two cases were found on cDWI (P = .66). CONCLUSION: qDWI induced fewer artifacts compared with cDWI in sedated patients, and similar frequencies of artifacts were induced by qDWI and by cDWI in unsedated patients. qDWI showed restricted diffusion comparable to cDWI
Diagnostic Value of DCE-MRI for Differentiating Malignant Adnexal Masses Compared with Contrast-enhanced-T1WI
Purpose: To compare the diagnostic performance of dynamic contrast-enhanced-MR (DCE-MR) and delayed contrast-enhanced (CE)-MRI added to unenhanced MRI, including diffusion weighted image (DWI) for differentiating malignant adnexal tumors, conducting a retrospective blinded image interpretation study. Methods: Data of 80 patients suspected of having adnexal tumors by ultrasonography between April 2008 and August 2018 were used for the study. All patients had undergone preoperative MRI and surgical resection at our institution. Four radiologists (two specialized in gynecological radiology and two non-specialized) were enrolled for blinded review of the MR images. A 3-point scale was used: 0 = benign, 1 = indeterminate, and 2 = malignant. Three imaging sets were reviewed: Set A, unenhanced MRI including DWI; Set B, Set A and delayed CE-T1WI; and Set C, Set A and DCE-MRI. Imaging criteria for benign and malignant tumors were given in earlier reports. The diagnostic performance of the three imaging sets of the four readers was calculated. Their areas under the curve (AUCs) were compared using the DeLong method. Results: Accuracies of Set B were 81%–88%. Those of Set C were 81%–85%. The AUCs of Set B were 0.83 and 0.89. Those of Set C were 0.81–0.86. For two readers, Set A showed lower accuracy and AUC than Set B/Set C (less than 0.80), although those were equivalent in other readers. No significant difference in AUCs was found among the three sequence sets. Intrareader agreement was moderate to almost perfect in Sets A and B, and substantial to almost perfect in Set C. Conclusion: DCE-MR showed no superiority for differentiating malignant adnexal tumors from benign tumors compared to delayed CE-T1WI with conventional MR and DWI
Signal Intensity and Volume of Pituitary and Thyroid Glands in Preterm and Term Infants
[Background]: Hypothalamic–pituitary–thyroid (HPT) maturation has not been extensively evaluated using neonatal MRI, even though both structures are visualized on MRI. [Hypothesis]: That signal intensity and volume of pituitary and thyroid (T) glands on MRI in neonates may be interrelated. [Study Type]: Retrospective. [Subjects]: In all, 102 participants. [Field Strength/Sequence]: 3.0T, T₁‐weighted pointwise encoding time reduction with radial acquisition (PETRA).[ Assessment]: The volume of interest of the anterior pituitary (AP), posterior pituitary (PP), and T on MRI were defined on T₁‐PETRA by two radiologists, and volumes of AP (AP_vol) and thyroid (T_vol) were calculated. Gestational age (GA), chronological age (CA), GA+CA, birth weight (BW), and thyroid function were recorded. Mean and maximum signal intensities of AP, PP, and T were normalized using signals from the pons and spinal cord as follows: signal ratio of anterior pituitary/pons (AP/pons), signal ratio of posterior pituitary/pons (PP/pons), and signal ratio of thyroid/cord (T/cord) T/cord, respectively. [Statistical Tests]: Correlations between signal intensity and volume measures and GA, CA, GA+CA, and BW were assessed using Pearson's correlation coefficient or Spearman's rank correlation coefficient. Thyroid function analysis and Tmean/cord, Tmax/cord, and T_vol were evaluated using the Steel–Dwass test. Results: APmean/pons correlated positively with GA (ρ = 0.62, P < 0.001) and BW (ρ = 0.74, P < 0.001), and negatively with CA (ρ = −0.86, P < 0.001) and GA+CA (ρ = −0.46, P < 0.001). PPmean/pons correlated positively with GA (ρ = 0.49, P < 0.001) and BW (ρ = 0.63, P < 0.001), and negatively with CA (ρ = −0.70, P < 0.001) and GA+CA (r = −0.38, P < 0.001). Tmean/cord correlated positively with GA (ρ = 0.48, P < 0.001) and BW (ρ = 0.55, P < 0.001), and negatively with CA (ρ = −0.59, P < 0.001) and GA+CA (ρ = −0.22, P = 0.03). AP_vol correlated positively with GA (ρ = 0.68, P < 0.001) and BW (ρ = 0.73, P < 0.001), and negatively with CA (ρ = −0.72, P < 0.001). T_vol correlated positively with GA (ρ = 0.50, P < 0.001) and BW (ρ = 0.61, P < 0.001), and negatively with CA (ρ = −0.54, P < 0.001). APmean/pons correlated positively with Tmean/cord (ρ = 0.61, P < 0.001). [Data Conclusion]: Signal and volume of pituitary and thyroid glands correlated positively with GA and BW, and negatively with CA in neonates. [Level of Evidence]: 4 [Technical Efficacy Stage]:
Radiation exposure and circulatory disease risk: Hiroshima and Nagasaki atomic bomb survivor data, 1950-2003
Objective To investigate the degree to which ionising radiation confers risk of mortality from heart disease and stroke
- …