50 research outputs found

    Threshold-based insulin-pump interruption for reduction of hypoglycemia

    Get PDF
    *Q1Artículo original224-232Background The threshold-suspend feature of sensor-augmented insulin pumps is designed to minimize the risk of hypoglycemia by interrupting insulin delivery at a preset sensor glucose value. We evaluated sensor-augmented insulin-pump therapy with and without the threshold-suspend feature in patients with nocturnal hypoglycemia. Methods We randomly assigned patients with type 1 diabetes and documented nocturnal hypoglycemia to receive sensor-augmented insulin-pump therapy with or without the threshold-suspend feature for 3 months. The primary safety outcome was the change in the glycated hemoglobin level. The primary efficacy outcome was the area under the curve (AUC) for nocturnal hypoglycemic events. Two-hour threshold-suspend events were analyzed with respect to subsequent sensor glucose values. Results A total of 247 patients were randomly assigned to receive sensor-augmented insulinpump therapy with the threshold-suspend feature (threshold-suspend group, 121 patients) or standard sensor-augmented insulin-pump therapy (control group, 126 patients). The changes in glycated hemoglobin values were similar in the two groups. The mean AUC for nocturnal hypoglycemic events was 37.5% lower in the thresholdsuspend group than in the control group (980±1200 mg per deciliter [54.4±66.6 mmol per liter]×minutes vs. 1568±1995 mg per deciliter [87.0±110.7 mmol per liter]×minutes, P<0.001). Nocturnal hypoglycemic events occurred 31.8% less frequently in the threshold-suspend group than in the control group (1.5±1.0 vs. 2.2±1.3 per patientweek, P<0.001). The percentages of nocturnal sensor glucose values of less than 50 mg per deciliter (2.8 mmol per liter), 50 to less than 60 mg per deciliter (3.3 mmol per liter), and 60 to less than 70 mg per deciliter (3.9 mmol per liter) were significantly reduced in the threshold-suspend group (P<0.001 for each range). After 1438 instances at night in which the pump was stopped for 2 hours, the mean sensor glucose value was 92.6±40.7 mg per deciliter (5.1±2.3 mmol per liter). Four patients (all in the control group) had a severe hypoglycemic event; no patients had diabetic ketoacidosis. Conclusions This study showed that over a 3-month period the use of sensor-augmented insulinpump therapy with the threshold-suspend feature reduced nocturnal hypoglycemia, without increasing glycated hemoglobin values. (Funded by Medtronic MiniMed; ASPIRE ClinicalTrials.gov number, NCT01497938.

    A prospective comparison of alginate-hydrogel with standard medical therapy to determine impact on functional capacity and clinical outcomes in patients with advanced heart failure (AUGMENT-HF trial)

    Get PDF
    Aims AUGMENT-HF was an international, multi-centre, prospective, randomized, controlled trial to evaluate the benefits and safety of a novel method of left ventricular (LV) modification with alginate-hydrogel. Methods: Alginate-hydrogel is an inert permanent implant that is directly injected into LV heart muscle and serves as a prosthetic scaffold to modify the shape and size of the dilated LV. Patients with advanced chronic heart failure (HF) were randomized (1 : 1) to alginate-hydrogel (n = 40) in combination with standard medical therapy or standard medical therapy alone (Control, n = 38). The primary endpoint of AUGMENT-HF was the change in peak VO2 from baseline to 6 months. Secondary endpoints included changes in 6-min walk test (6MWT) distance and New York Heart Association (NYHA) functional class, as well as assessments of procedural safety. Results: Enrolled patients were 63 ± 10 years old, 74% in NYHA functional class III, had a LV ejection fraction of 26 ± 5% and a mean peak VO2 of 12.2 ± 1.8 mL/kg/min. Thirty-five patients were successfully treated with alginate-hydrogel injections through a limited left thoracotomy approach without device-related complications; the 30-day surgical mortality was 8.6% (3 deaths). Alginate-hydrogel treatment was associated with improved peak VO2 at 6 months—treatment effect vs. Control: +1.24 mL/kg/min (95% confidence interval 0.26–2.23, P = 0.014). Also 6MWT distance and NYHA functional class improved in alginate-hydrogel-treated patients vs. Control (both P < 0.001). Conclusion: Alginate-hydrogel in addition to standard medical therapy for patients with advanced chronic HF was more effective than standard medical therapy alone for improving exercise capacity and symptoms. The results of AUGMENT-HF provide proof of concept for a pivotal trial. Trial Registration Number NCT01311791

    Combination therapy in type 2 diabetes mellitus: adding empagliflozin to basal insulin

    Full text link
    Type 2 diabetes mellitus (T2DM) management is complex, with few patients successfully achieving recommended glycemic targets with monotherapy, most progressing to combination therapy, and many eventually requiring insulin. Sodium glucose cotransporter 2 (SGLT2) inhibitors are an emerging class of antidiabetes agents with an insulin-independent mechanism of action, making them suitable for use in combination with any other class of antidiabetes agents, including insulin. This review evaluates a 78-week, randomized, double-blind, placebo-controlled trial investigating the impact of empagliflozin, an SGLT2 inhibitor, as add-on to basal insulin in patients with inadequate glycemic control on basal insulin, with or without metformin and/or a sulfonylurea. Empagliflozin added on to basal insulin resulted in significant and sustained reductions in glycated hemoglobin (HbA1c) levels compared with placebo. Empagliflozin has previously been shown to induce weight loss, and was associated with sustained weight loss in this study. This combination therapy was well tolerated, with similar levels of hypoglycemic adverse events in the empagliflozin and placebo groups over the 78-week treatment period. Urinary tract infections and genital infections, side effects associated with SGLT2 inhibitors, were reported more commonly in the empagliflozin group; however, such events led to treatment discontinuation in very few patients. These findings suggest that, with their complementary mechanisms of action, empagliflozin added on to basal insulin may be a useful treatment option in patients on basal insulin who need additional glycemic control without weight gain

    Baseline Predictors of A1C Reduction in Adults Using Sensor-Augmented Pump Therapy or Multiple Daily Injection Therapy: The STAR 3 Experience

    Get PDF
    Background: Baseline characteristics from the adult cohort of a randomized controlled trial comparing sensoraugmented pump (SAP) and multiple daily injection (MDI) therapy were analyzed for significant relationships with -0.5% A1C change at 1 year of therapy without incidence of severe hypoglycemia (defined as A1C benefit). Methods: Baseline characteristics were compared with A1C benefit. Statistically significant predictors were analyzed further to determine appropriate cutpoints of relative A1C benefit. Results: Baseline A1C ≥ 9.1%, age at randomization ≥ 36 years, and age at diabetes diagnosis of ≥ 17 years were associated with a greater SAP benefit relative to MDI than other cutpoints. Conclusions: People with type 1 diabetes who had a high A1C and who were older at diagnosis and older at randomization experienced the most benefit from SAP therapy

    A Practical Approach to Using Trend Arrows on the Dexcom G5 CGM System for the Management of Adults With Diabetes

    Full text link
    After reviewing previously published methods, we developed a practical approach to adjusting insulin doses based on insulin sensitivity for adult patients with diabetes using rtCGM trend arrow data

    Efficacy and safety of once-Weekly semaglutide versus exenatide ER in subjects with type 2 diabetes (SUSTAIN 3): A 56-Week, open-Label, randomized clinical trial

    Full text link
    OBJECTIVE: To compare the efficacy and safety of once-weekly semaglutide 1.0 mg s.c. with exenatide extended release (ER) 2.0 mg s.c. in subjects with type 2 diabetes. RESEARCH DESIGN AND METHODS: In this phase 3a, open-label, parallel-group, randomized controlled trial, 813 subjects with type 2 diabetes taking oral antidiabetic drugs were randomized (1:1) to semaglutide 1.0 mg or exenatide ER 2.0 mg for 56 weeks. The primary end point was change from baseline in HbA1c at week 56. RESULTS: Mean HbA1c (8.3% [67.7 mmol/mol] at baseline) was reduced by 1.5% (16.8 mmol/mol) with semaglutide and 0.9% (10.0 mmol/mol) with exenatide ER (estimated treatment difference vs. exenatide ER [ETD] -0.62% [95% CI -0.80, -0.44] [-6.78 mmol/mol (95% CI -8.70, -4.86)]; P < 0.0001 for noninferiority and superiority). Mean body weight (95.8 kg at baseline) was reduced by 5.6 kg with semaglutide and 1.9 kg with exenatide ER (ETD -3.78 kg [95% CI -4.58, -2.98]; P < 0.0001). Significantly more subjects treated with semaglutide (67%) achieved HbA1c <7.0% (<53 mmol/mol) versus those taking exenatide ER (40%). Both treatments had similar safety profiles, but gastrointestinal adverse events were more common in semaglutide-treated subjects (41.8%) than in exenatide ER-treated subjects (33.3%); injection-site reactions were more frequent with exenatide ER (22.0%) than with semaglutide (1.2%). CONCLUSIONS: Semaglutide 1.0 mg was superior to exenatide ER 2.0 mg in improving glycemic control and reducing body weight after 56 weeks of treatment; the drugs had comparable safety profiles. These results indicate that semaglutide treatment is highly effective for subjects with type 2 diabetes who are inadequately controlled on oral antidiabetic drugs

    Approach to Using Trend Arrows in the FreeStyle Libre Flash Glucose Monitoring Systems in Adults

    Full text link
    The use of personal continuous glucose monitoring (CGM) has expanded dramatically among individuals with diabetes. CGM systems provide retrospective data, as well as the current glucose value and trend arrow data, which indicate the direction and velocity of changing glucose. In 2017, Aleppo and colleagues developed a simplified approach for adults with diabetes to safely adjust rapid-acting insulin doses using trend arrow information in the Dexcom G5 CGM system. Since then, the FreeStyle Libre and FreeStyle Libre 14-day CGM systems have become available in the United States; however, guidance on using trend arrow data that take the unique features of these systems into consideration is lacking. Specifically, the FreeStyle Libre systems do not have automatic alarms, which impact how the system and trend arrow data are used. The Endocrine Society convened an expert panel to address this gap and develop an approach to adjusting rapid-acting insulin doses for adults using trend arrows in the FreeStyle Libre systems. We based our approach on previous work and expanded upon engagement and scanning recommendations, and we incorporated pre-exercise planning specific to these systems. Our approach provides insulin dose adjustments as discrete insulin units based on an individual\u27s insulin sensitivity and directionality of the trend arrow. We focus on the needs of patients treated with multiple daily injections because these individuals currently make up a greater proportion of individuals on intensive insulin therapy. Our recommendations are intended to provide a safe, practical approach to using trend arrows in the FreeStyle Libre systems
    corecore